Related papers: Optical layout for a 10m Fabry-P\'erot Michelson i…
Self-heterodyne fiber interferometers have been shown to be capable of stabilizing lasers to ultra-narrow linewidths and present an excellent alternative to high finesse cavities for frequency stabilization. In addition to suppressing…
We present a Michelson-type microwave interferometer for use in ferromagnetic resonance experiments. The interferometer is capable of broadband operation without manual adjustment of phase delay or amplitude attenuation. A prototype of the…
We describe an apparatus for the implementation of hybrid optomechanical systems at 4 K. The platform is based on a high-finesse, micrometer-scale fiber Fabry-Perot cavity, which can be widely tuned using piezoelectric positioners. A…
Precision measurements are reported of the cross-spectrum of rotationally-induced differential position displacements in a pair of colocated 39 m long, high power Michelson interferometers. One arm of each interferometer is bent…
We present a new micromechanical resonator designed for cavity optomechanics. We have used a micropillar geometry to obtain a high-frequency mechanical resonance with a low effective mass and a very high quality factor. We have coated a…
Suitable shaping (in particular, flattening and broadening) of the laser beam has recently been proposed as an effective device to reduce internal (mirror) thermal noise in advanced gravitational wave interferometric detectors. Based on…
Interferometric gravitational wave antennas are based on Michelson interferometers whose sensitivity to small differential length changes has been enhanced by adding multiple coupled optical resonators. The use of optical cavities is…
A fundamental limit to the sensitivity of optical interferometry is thermal noise that drives fluctuations in the positions of the surfaces of the interferometer's mirrors, and thereby in the phase of the intracavity field. Schemes for…
Optical multilayer coatings of high-reflective mirrors significantly determine the properties of Fabry-Perot resonators. Thermal (Brownian) noise in these coatings produce excess phase noise which can seriously degrade the sensitivity of…
The optical design of the Einstein Telescope (ET) is based on a dual-recycled Michelson interferometer with Fabry-Perot cavities in the arms. ET will be constructed in a new infrastructure, allowing us to consider different technical…
Residual motion of the arm cavity mirrors is expected to prove one of the principal impediments to systematic lock acquisition in advanced gravitational-wave interferometers. We present a technique which overcomes this problem by employing…
A major limitation of laser interferometers using continuous wave lasers are parasitic light fields, such as ghost beams, scattered or stray light, which can cause non-linear noise. This is especially relevant for laser interferometric…
We demonstrate a simple, compact, and cost-effective laser noise reduction method for stabilizing an extended cavity diode laser to a 3x105 finesse mirror Fabry-P\'erot (F-P) cavity corresponding to resonance linewidth of 10 kHz using a…
We report a laser noise reduction method by locking it to an actively stabilized fiber-based Mach Zehnder interferometer with 10 km optical fiber to achieve large arm imbalance. An acousto optic modulator is used for interferometer…
Displacement calibration of nanomechanical plate resonators presents a challenging task. Large nanomechanical resonator thickness reduces the amplitude of the resonator motion due to its increased spring constant and mass, and its unique…
Recent experimental progress in table-top experiments or gravitational-wave interferometers has enlightened the unique displacement sensitivity offered by optical interferometry. As the mirrors move in response to radiation pressure, higher…
We describe the design, construction, and characterization of a medium-finesse Fabry-P\'erot cavity for simultaneous frequency stabilization of two lasers operating at 960 and 780 nm wavelengths, respectively. The lasers are applied in…
The factors limiting the resolution of displacement sensor based on extrinsic Fabry-Perot interferometer were studied. An analytical model giving the dependency of EFPI resolution on the parameters of an optical setup and a sensor…
When illuminated by a white light source, the discrete resonances of a Fabry-Perot interferometer (FP) provide a broad bandwidth, comb-like spectrum useful for frequency calibration. We report on the design, construction and laboratory…
We theoretically and experimentally study the effect of the coupled-resonator-induced transparency in the Michelson interferometer with the dual-recycled configuration, which is equivalent to the adjustable coupled resonator. The coupling…