Related papers: Optical layout for a 10m Fabry-P\'erot Michelson i…
We propose a marginally stable optical resonator suitable for atom interferometry. The resonator geometry is based on two flat mirrors at the focal planes of a lens that produces the large beam waist required to coherently manipulate cold…
Thermally induced fluctuations impose a fundamental limit on precision measurement. In optical interferometry, the current bounds of stability and sensitivity are dictated by the excess mechanical damping of the high-reflectivity coatings…
Thermodynamically induced length fluctuations of high-reflectivity mirror coatings put a fundamental limit on sensitivity and stability of precision optical interferometers like gravitational wave detectors and ultra-stable lasers. The main…
We report the frequency stabilization of an erbium-doped fiber distributed-feedback laser using an all-fiber based Michelson interferometer of large arm imbalance. The interferometer uses a 1 km SMF-28 optical fiber spool and an acousto…
A stable optical resonator has been built using a 30 micrometer-wide, metal-coated microcantilever as one mirror. The second mirror was a 12.7 mm-diameter concave dielectric mirror. By positioning the two mirrors 75 mm apart in a…
Quantum noise limits the sensitivity of precision measurement devices, such as laser interferometer gravitational-wave observatories and axion detectors. In the shot-noise-limited regime, these resonant detectors are subject to a trade-off…
We measure the motional fluctuations of a micromechanical mirror using a Michelson interferometer, and demonstrate its interferometric stability. The position stability of the micromirror is dominated by the thermal mechanical noise of the…
The detection of high-frequency gravitational waves around kHz is critical to understanding the physics of binary neutron star mergers. A new interferometer design has been proposed in [Phys. Rev. X {\bf 13}, 021019 (2023)], featuring an…
Using one arm of the Michelson interferometer and the power recycling mirror of the interferometric gravitational wave detector GEO600, we created a Fabry-Perot cavity with a length of 1200 m. The main purpose of this experiment was to…
Direct observations of gravitational waves at frequencies below 10 Hz will play crucial roles for fully exploiting the potential of gravitational wave astronomy. One approach to pursue this direction is the utilization of laser…
By reentering into laser interferometers, scattered or stray light introduces non-linear noise. This is a major limitation of precision interferometers as preventing such parasitic light is nearly impossible. Thus, substantial effort is put…
Fundamental sensitivity of an optical interferometric gravitational wave detector increases with increase of the optical power which, in turn, limited because of the opto-mechanical parametric instabilities of the interferometer. We propose…
The Fabry-P\'erot resonator is one of the most widely used optical devices, enabling scientific and technological breakthroughs in diverse fields including cavity QED, optical clocks, precision length metrology and spectroscopy. Though…
We report on two ultrastable lasers each stabilized to independent silicon Fabry-P\'erot cavities operated at 124 K. The fractional frequency instability of each laser is completely determined by the fundamental thermal Brownian noise of…
Fiber Fabry--Perot (FFP) resonators of a few centimeters are optimized as a function of the reflectivity of the mirrors and the dimensions of the intra-cavity waveguide. Loaded quality factor in excess of 10^9, with an optimum of…
We investigate the shot noise limited sensitivity of a four-mirror cavity enhanced Michelson interferometer. The intention of this interferometer topology is the reduction of thermal lensing and the impact of the interferometers contrast…
Michelson-type laser-interferometric gravitational-wave (GW) observatories employ very high light powers as well as transmissively- coupled Fabry-Perot arm resonators in order to realize high measurement sensitivities. Due to the absorption…
The topic of this thesis is the theoretical analysis of the optomechanical coupling effects in a high-finesse optical cavity, and the experimental realization of such a device. Radiation pressure exerted by light limits the sensitivity of…
A fundamental limit to the sensitivity of optical interferometers is imposed by Brownian thermal fluctuations of the mirrors' surfaces. This thermal noise can be reduced by using larger beams which "average out" the random fluctuations of…
Lasers stabilized to vacuum-gap Fabry-P\'erot optical reference cavities display extraordinarily low noise and high stability, with linewidths much less than 1 Hz. These lasers can expand into new applications and ubiquitous use with the…