Related papers: Lock-in detection for pulsed electrically detected…
We present pulsed electrically detected magnetic resonance (EDMR) measurements at low magnetic fields using posphorus-doped silicon with natural isotope composition as a model system. Our measurements show that pulsed EDMR experiments, well…
Electrically detected magnetic resonance (EDMR) is applied to mm size devices with implanted leads and a 50 micron square gap laid down on bulk phosphorus doped silicon. Devices with a range of phosphorus concentrations and surface types…
We present the results of electrically-detected magnetic resonance (EDMR) experiments on silicon with ion-implanted phosphorus nanostructures, performed at 5 K. The devices consist of high-dose implanted metallic leads with a square gap,…
We report the development of the frequency-modulation (FM) method for measuring electron spin resonance (ESR) absorption in the 210-420 GHz frequency range. We demonstrate that using a high-frequency ESR spectrometer without resonating…
We present a broadband microwave setup for electrically detected magnetic resonance (EDMR) based on microwave antennae with the ability to apply arbitrarily shaped pulses for the excitation of electron spin resonance (ESR) and nuclear…
High-precision measurements benefit from lock-in detection of small signals. Here we discuss the extension of lock-in detection to many channels, using mutually orthogonal modulation waveforms, and show how the the choice of waveforms…
We report pulsed electron-spin resonance (ESR) measurements on an ensemble of Bismuth donors in Silicon cooled at 10mK in a dilution refrigerator. Using a Josephson parametric microwave amplifier combined with high-quality factor…
We report on electron spin resonance (ESR) measurements of phosphorus donors localized in a 200 square micron area below the inductive wire of a lumped element superconducting resonator. By combining quantum limited parametric amplification…
We demonstrate radio frequency (RF) readout of electrically detected magnetic resonance in phosphorus-doped silicon metal-oxide field-effecttransistors (MOSFETs), operated at liquid helium temperatures. For the first time, the Si:P…
We demonstrate that the bandwidth of pulsed electrically detected magnetic resonance can be increased to at least 80 MHz using a radio frequency-reflectometry detection scheme. Using this technique, we measure coherent spin oscillations in…
The use of superconducting micro-resonators in combination with quantum-limited Josephson parametric amplifiers has in recent years lead to more than four orders of magnitude improvement in the sensitivity of pulsed Electron Spin Resonance…
The investigation of paramagnetic species (such as point defects, dopants, and impurities) in solid-state electronic devices is significant because of their effect on device performance. Conventionally, these species are detected and imaged…
Presented are magnetization measurements on a crystal of Fe8 single-molecule magnets using a Hall probe magnetometer. Irradiation with microwaves at frequencies of 92 and 110-120 GHz leads to the observation of electron paramagnetic…
We demonstrate microwave manipulation of the spin states of electrically injected spin-polarized electrons in silicon. Although the silicon channel is bounded by ferromagnetic metal films, we show that moderate microwave power can be…
Counting the microwave photons emitted by an ensemble of electron spins when they relax radiatively has recently been proposed as a sensitive method for electron paramagnetic resonance (EPR) spectroscopy, enabled by the development of…
We present a rapid-scanning approach to fluorescence-detected two-dimensional electronic spectroscopy that combines acousto-optic phase-modulation with digital lock-in detection. The approach shifts the signal detection window to suppress…
Under negative feedback, the quality factor Q of a radio-frequency magnetometer can be decreased by more than two orders of magnitude, so that any initial perturbation of the polarized spin system can be rapidly damped, preparing the…
Electrically-detected magnetic resonance (EDMR) provides a highly sensitive method for reading out the state of donor spins in silicon. The technique relies on a spin-dependent recombination (SDR) process involving dopant spins that are…
This article proposes a scheme for nitrogen-vacancy (NV) center magnetometry that combines the advantages of lock-in detection and pulse-type scheme. The optimal conditions, optimal sensitivity, and noise-suppression capability of the…
Quantum lock-in amplification raises the detection sensitivity of magnetic fields to unprecedented levels by phase-locked pumping the Zeeman levels of a single trapped atom. However, random spin precessions limits the useful detection range…