English
Related papers

Related papers: Fast Monte Carlo Simulation for Patient-specific C…

200 papers

X-ray CT dose measurement has mainly been performed using an ionization chamber dosimeter. Therefore, the dose distribution has not been sufficiently studied. We investigated the importance of evaluating the two or three-dimensional dose…

A novel phase-space source implementation has been designed for GPU-based Monte Carlo dose calculation engines. Due to the parallelized nature of GPU hardware, it is essential to simultaneously transport particles of the same type and…

Medical Physics · Physics 2013-06-21 Reid Townson , Xun Jia , Zhen Tian , Yan Jiang Graves , Sergei Zavgorodni , Steve B Jiang

This work summarises the results of a comparison organized by EURADOS focused on the usage of the ICRP Reference Computational Phantoms. This activity aimed to provide training for the implementation of voxel phantoms in Monte Carlo…

With increasing patient and staff X-ray radiation awareness, many efforts have been made to develop accurate patient dose estimation methods. To date, Monte Carlo (MC) simulations are considered golden standard to simulate the interaction…

Treatment planning system calculations in inhomogeneous regions may present significant inaccuracies due to loss of electronic equilibrium. In this study, three different dose calculation algorithms, pencil beam, collapsed cone, and…

Medical Physics · Physics 2015-03-12 Sung Jin Kim , Dong Ho Kim , Sung Kyu Kim

In radiotherapy, a trade-off exists between computational workload/speed and dose calculation accuracy. Calculation methods like pencil-beam convolution can be much faster than Monte-Carlo methods, but less accurate. The dose difference,…

Medical Physics · Physics 2020-05-18 Yixun Xing , Ph. D. , You Zhang , Ph. D. , Dan Nguyen , Ph. D. , Mu-Han Lin , Ph. D. , Weiguo Lu , Ph. D. , Steve Jiang , Ph. D

Purpose: To validate the accuracy of 4D Monte Carlo (4DMC) simulations to calculate dose deliveries to a deforming anatomy in the presence of realistic respiratory motion traces. A previously developed deformable lung phantom comprising an…

Medical Physics · Physics 2023-05-04 Sara Gholampourkashi , Joanna E. Cygler , Bernie Lavigne , Emily Heath

The gamma-index dose comparison tool has been widely used to compare dose distributions in cancer radiotherapy. The accurate calculation of gamma-index requires an exhaustive search of the closest Euclidean distance in the high-resolution…

Medical Physics · Physics 2015-05-20 Xuejun Gu , Xun Jia , Steve B. Jiang

Monte Carlo (MC) is generally considered as the most accurate dose calculation tool for particle therapy. However, a proper description of the beam particles kinematics is a necessary input for a realistic simulation. Such a description can…

Radiation Treatment Planning (RTP) is the process of planning the appropriate external beam radiotherapy to combat cancer in human patients. RTP is a complex and compute-intensive task, which often takes a long time (several hours) to…

Distributed, Parallel, and Cluster Computing · Computer Science 2021-09-21 Felix Liu , Niclas Jansson , Artur Podobas , Albin Fredriksson , Stefano Markidis

Targeting at the development of an accurate and efficient dose calculation engine for online adaptive radiotherapy, we have implemented a finite size pencil beam (FSPB) algorithm with a 3D-density correction method on GPU. This new…

Medical Physics · Physics 2015-05-27 Xuejun Gu , Urszula Jelen , Jinsheng Li , Xun Jia , Steve B. Jiang

Purpose: To investigate the validity of two Monte Carlo simulation absolute dosimetry approaches in the case of a small field dedicated `D'-shaped collimator used for the retinoblastoma treatment with external photon beam radiotherapy.…

Medical Physics · Physics 2018-09-25 P. A. Mayorga , L. Brualla , A. Flühs , W. Sauerwein , A. M. Lallena

Two full rotating gantry with different nozzles (Multipurpose nozzle with MLC, Scanning Dedicated nozzle) with conventional cyclotron system is installed and under commissioning for various proton treatment options at Samsung Medical Center…

Skin dose in radiotherapy is a key issue for reducing patient side effects, but dose calculations in this high-gradient region remains a challenge. To support radiation therapists and medical physicist in their decisions, a computational…

Ultra low radiation dose in X-ray Computed Tomography (CT) is an important clinical objective in order to minimize the risk of carcinogenesis. Compressed Sensing (CS) enables significant reductions in radiation dose to be achieved by…

Cancer is a primary cause of morbidity and mortality worldwide. The radiotherapy plays a more and more important role in cancer treatment. In the radiotherapy, the dose distribution maps in patient need to be calculated and evaluated for…

Medical Physics · Physics 2019-10-18 Zhao Peng , Hongming Shan , Tianyu Liu , Xi Pei , Jieping Zhou , Ge Wang , X. George Xu

Cone beam computed tomography (CBCT) for breast imaging has potential to replace conventional mammograms. However, concerns over dose and image quality prevent CBBCT systems from the clinical trial phase to next stage. The time of flight…

Medical Physics · Physics 2021-02-01 Ignacio O. Romero , Changqing Li

Purpose: To assess the effects of brain movements induced by heartbeat on dose distributions in synchrotron micro- and mini-beam radiaton therapy and to develop a model to help guide decisions and planning for future clinical trials.…

Medical Physics · Physics 2018-09-25 Francisco Manchado de Sola , Manuel Vilches , Yolanda Prezado , Antonio M. Lallena

The Centers for Medicare & Medicaid Services (CMS) has introduced CMS1074v2, a quality measure for computed tomography (CT) that assesses radiation dose and image quality across 18 CT exam categories. This measure mandates the calculation…

Medical Physics · Physics 2025-03-11 Gary Y Ge , Charles M Weaver , Jie Zhang

Pencil x-ray beam imaging provides superior spatial resolution than other imaging geometries like sheet beam and cone beam geometries due to the illumination of a line instead of an area or volume. However, the pencil beam geometry suffers…

Medical Physics · Physics 2021-02-01 Ignacio O. Romero , Changqing Li