English
Related papers

Related papers: Radiation hardness study of calorimeter active ele…

200 papers

Among the top priorities for high-energy astronomy in the coming decade are sensitive surveys in the hard X-ray/soft \gamma-ray (10-600 keV) and medium-energy \gamma-ray (0.2-80 MeV) bands. Historically, observations in the soft and medium…

Instrumentation and Methods for Astrophysics · Physics 2013-02-26 Alexei Ulyanov , Lorraine Hanlon , Sheila McBreen , Suzanne Foley , David Byrne

We present the first application of polysiloxane-based scintillators as active medium in a shashlik sampling calorimeter. These results were obtained from a testbeam campaign of a $\sim$6$\times$6$\times$45 cm$^3$ (13 $X_0$ depth)…

The CALICE collaboration is presently constructing a test hadron calorimeter (HCAL) with 7620 scintillator tiles read out by novel photo-detectors - Silicon Photomultipliers (SiPMs). This prototype is the first device which uses SiPMs on a…

Instrumentation and Detectors · Physics 2008-11-26 M. Danilov

In nuclear, particle and astroparticle physics experiments, calorimeters are used to measure the properties of particles with kinetic energies that range from a fraction of 1 eV to 10^20 eV or more. These properties are not necessarily…

Instrumentation and Detectors · Physics 2018-10-17 Richard Wigmans

The electromagnetic barrel calorimeter is one of the main components of the planned GlueX experiment. It will consist of 48 modules made of consecutive layers of 4 m long lead sheet and fast green scintillator fibers for an overall number…

Instrumentation and Detectors · Physics 2009-11-13 M. Barbi

A study has been performed to understand the effects of radiation damage on various plastic scintillator tiles considered for a possible upgrade of the hadron calorimeter of the CMS detector. Measurements were made with unirradiated tiles…

Instrumentation and Detectors · Physics 2024-09-30 The CMS HCAL Collaboration

A prototype of a dual-readout calorimeter using brass capillary tubes surrounding scintillating and clear plastic optical fibres was tested using beams of particles with energies between 10 and 100 GeV produced by the CERN SPS. The scope of…

A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a…

Instrumentation and Detectors · Physics 2014-07-24 CALICE Collaboration , K. Francis , J. Repond , J. Schlereth , J. Smith , L. Xia , E. Baldolemar , J. Li , S. T. Park , M. Sosebee , A. P. White , J. Yu , G. Eigen , Y. Mikami , N. K. Watson , M. A. Thomson , D. R. Ward , D. Benchekroun , A. Hoummada , Y. Khoulaki , J. Apostolakis , A. Dotti , G. Folger , V. Ivantchenko , A. Ribon , V. Uzhinskiy , C. Carloganu , P. Gay , S. Manen , L. Royer , M. Tytgat , N. Zaganidis , G. C. Blazey , A. Dyshkant , J. G. R. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , U. Cornett , D. David , A. Ebrahimi , G. Falley , K. Gadow , P. Goettlicher , C. Guenter , O. Hartbrich , B. Hermberg , S. Karstensen , F. Krivan , K. Krueger , B. Lutz , S. Morozov , V. Morgunov , C. Neubueser , M. Reinecke , F. Sefkow , P. Smirnov , M. Terwort , E. Garutti , S. Laurien , S. Lu , I. Marchesini , M. Matysek , M. Ramilli , K. Briggl , P. Eckert , T. Harion , H. -Ch. Schultz-Coulon , W. Shen , R. Stamen , B. Bilki , E. Norbeck , D. Northacker , Y. Onel , G. W. Wilson , K. Kawagoe , Y. Sudo , T. Yoshioka , P. D. Dauncey , M. Wing , F. Salvatore , E. Cortina Gil , S. Mannai , G. Baulieu , P. Calabria , L. Caponetto , C. Combaret , R. Della Negra , G. Grenier , R. Han , J-C. Ianigro , R. Kieffer , I. Laktineh , N. Lumb , H. Mathez , L. Mirabito , A. Petrukhin , A. Steen , W. Tromeur , M. Vander Donckt , Y. Zoccarato , E. Calvo Alamillo , M. -C. Fouz , J. Puerta-Pelayo , F. Corriveau , B. Bobchenko , M. Chadeeva , M. Danilov , A. Epifantsev , O. Markin , R. Mizuk , E. Novikov , V. Popov , V. Rusinov , E. Tarkovsky , D. Besson , P. Buzhan , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , V. Tikhomirov , C. Kiesling , K. Seidel , F. Simon , C. Soldner , L. Weuste , M. S. Amjad , J. Bonis , S. Callier , S. Conforti di Lorenzo , P. Cornebise , Ph. Doublet , F. Dulucq , J. Fleury , T. Frisson , N. van der Kolk , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Poeschl , L. Raux , J. Rouene , N. Seguin-Moreau , M. Anduze , V. Balagura , V. Boudry , J-C. Brient , R. Cornat , M. Frotin , F. Gastaldi , E. Guliyev , Y. Haddad , F. Magniette , G. Musat , M. Ruan , T. H. Tran , H. Videau , B. Bulanek , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , D. Lednicky , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , H. Ghazlane , K. Kotera , H. Ono , T. Takeshita , S. Uozumi , D. Jeans , S. Chang , A. Khan , D. H. Kim , D. J. Kong , Y. D. Oh , M. Goetze , J. Sauer , S. Weber , C. Zeitnitz

Future HEP experiments present stringent challenges to calorimeter materials in radiation tolerance, time response and project cost. The 2019 report of the DOE Basic Research Needs Study on High Energy Physics Detector Research and…

Instrumentation and Detectors · Physics 2022-03-15 Minfang Yeh , Ren-Yuan Zhu

Scintillating crystals are used for calorimetry in several high-energy physics experiments. For many of them, performance has to be ensured in very difficult operating conditions, like a high radiation environment and large particle fluxes,…

Instrumentation and Detectors · Physics 2017-08-23 F. Nessi-Tedaldi

This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from -50 {\deg}C to 150 {\deg}C. The aim of this modeling is the evaluation of the feasibility and…

Instrumentation and Detectors · Physics 2016-01-11 Elysée Obame Ndong , Olivier Gallot-Lavallée , Frédéric Aitken

We present preliminary results on efficiency and light collection uniformity read out performances of different assemblies of scintillator tiles, coupled with solid state photon detectors of different make. Our test beam data suggest that…

Instrumentation and Detectors · Physics 2009-01-14 A. Calcaterra , R. de Sangro , G. Finocchiaro , E. Kuznetsova , P. Patteri , M. Piccolo

High performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include…

In particle physics, homogeneous calorimeters are used to measure the energy of particles as they interact with the detector material. Although not as precise as trackers or muon detectors, these calorimeters provide valuable insights into…

The advent of the silicon photomultiplier has allowed the development of highly segmented calorimeters using plastic scintillator as the active media, with photodetectors embedded in the calorimeter, in dimples in the plastic. To reduce the…

Instrumentation and Detectors · Physics 2024-01-23 B. Kronheim , A. Belloni , T. K. Edberg , S. C. Eno , C. Howe , C. Palmer , C. Papageorgakis , M. Paranjpe , S. Sriram

A hybrid dual-readout calorimeter concept, comprising both electromagnetic and hadronic sections, has recently been proposed to meet the performance requirements of experiments at future e$^{+}$e$^{-}$ colliders. The front compartment…

Instrumentation and Detectors · Physics 2026-03-20 Andrea Benaglia , Flavia Cetorelli , Marco Toliman Lucchini , Etiennette Auffray , Louis Roux , Julie Delenne

TileCal, the central hadronic calorimeter of the ATLAS detector is composed of plastic scintillators interleaved by steel plates, and wavelength shifting optical fibres. The optical properties of these components are known to suffer from…

Instrumentation and Detectors · Physics 2019-05-06 R. Pedro

Scintillating calorimeters are cryogenic detectors combining a measurement of scintillation with one of phonons to provide particle identification. In view of developing alkali halide devices of this type able to check the DAMA/LIBRA claim…

Instrumentation and Detectors · Physics 2015-04-08 Patrick Nadeau , Michael Clark , P. C. F. Di Stefano , J. -C. Lanfranchi , S. Roth , M. von Sivers , Itay Yavin

The performance of the electromagnetic calorimeter of the HERMES experiment is described. The calorimeter consists of 840 radiation resistant F101 lead-glass counters. The response to positrons up to 27.5 GeV, the comparison between the…

High Energy Physics - Experiment · Physics 2015-06-25 H. Avakian