English
Related papers

Related papers: An improved design of spark-protected microstrip g…

200 papers

New highly transparent, hydrophobic silica aerogels with refractive indices of 1.01 to 1.07 have been produced by Aspen Aerogels, Inc., and select tiles have been tested using an electron beam at the DESY, Hamburg facility. A…

Instrumentation and Detectors · Physics 2018-01-15 D. Blyth , R. Alarcon , R. Begag , J. Holmes , J. Stryker

The knowledge of capacitance in semiconductor micro-strip detectors is important for a correct design, simulation and understanding of the detectors. Analytical approaches can efficiently complement numerical methods providing quick results…

Instrumentation and Detectors · Physics 2010-02-18 Paolo Walter Cattaneo

In the CBM (Compressed Baryonic Matter) experiment constructed at the Facility for Anti-proton and Ion Research (Fair) at GSI, Darmstadt, Germany, MRPC(Multi-gap Resistive Plate Chamber) is adopted to construct the large TOF…

The present work involves the comparison of various bulk Micromegas detectors having different design parameters. Six detectors with amplification gaps of $64,~128,~192,~220 ~\mu\mathrm{m}$ and mesh hole pitch of $63,~78 ~\mu\mathrm{m}$…

Instrumentation and Detectors · Physics 2016-05-12 Purba Bhattacharya , Sudeb Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar , Paul Colas , David Attie

This paper presents the design and fabrication of batch-processed cantilever probes with electrical shielding for scanning microwave impedance microscopy. The diameter of the tip apex, which defines the electrical resolution, is less than…

Instrumentation and Detectors · Physics 2013-01-14 Yongliang Yang , Keji Lai , Qiaochu Tang , Worasom Kundhikanjana , Michael A Kelly , Kun Zhang , Zhi-xun Shen , Xinxin Li

We describe a new micro-pattern gas detector structure comprising a multi-layer hole-type multiplier (M-THGEM) combined with two in-built electrode meshes: the Multi-Mesh THGEM-type multiplier (MM-THGEM). Suitable potential differences…

Instrumentation and Detectors · Physics 2018-08-01 Rui de Olivera , Marco Cortesi

Resistive Plate Chamber detectors are largely used in current High Energy Physics experiments, typically operated in avalanche mode with large fractions of Tetrafluoroethane (C2H2F4), a gas recently banned by the European Union due to its…

Instrumentation and Detectors · Physics 2024-10-16 Luca Quaglia

We have developed and successfully used several innovative designs of detectors with solid photocathodes. The main advantage of these detectors is that rather high gains (>10E4) can be achieved in a single multiplication step. This is…

Instrumentation and Detectors · Physics 2009-11-07 P. Carlson , C. Iacobeaus , T. Francke , B. Lund-Jensen , L. Periale , V. Peskov , I. Rodionov

We describe a detector of alpha particles based on wire type counters (single-wire and multiwire) operating in ambient air at high gas gains (100-1000). The main advantages of these detectors are: low cost, robustness and ability to operate…

Instrumentation and Detectors · Physics 2010-06-08 G. Charpak , P. Benaben , P. Breuil , E. Nappi , P. Martinengo , V. Peskov

A new design of highly granular hadronic calorimeter using Glass Resistive Plate Chambers (GRPCs) with embedded electronics has been proposed for the future International Linear Collider (ILC) experiments. It features a 2-bit threshold…

Detailed tests and analysis of ageing effects of high irradiation dose on Multi-Strip Multi-Gap Resistive Plate Counters based on low resistivity glass electrodes were performed. MSMGRPC efficiency and cluster size before irradiation are…

Current radiation portal monitors at sea ports and international borders that employ standard radiation detection techniques are not very sensitive to nuclear contraband that is well shielded to absorb emanating radiation. Muon Tomography…

Instrumentation and Detectors · Physics 2016-11-17 M. Hohlmann , K. Gnanvo , L. Grasso , J. B. Locke , A. Quintero , D. Mitra

To meet the need for a high counting rate and high time resolution in future high-energy physics experiments, a prototype of a gas photodetector with an RPC structure was developed. Garfield++ simulated the detector's performance, and the…

Instrumentation and Detectors · Physics 2024-07-30 Yiding Zhao , D. Hu , M. Shao , Y. Zhou , S. Lv , Xiangqi Tian , Anqi Wang , Xueshen Lin , Hao Pang , Y. Suna

In this study we investigate the stability limits of Micromegas detectors upon irradiation with alpha particles. The results are obtained with meshes with different optical transparency and geometry of wires. The measurements are performed…

Instrumentation and Detectors · Physics 2023-06-13 P. Gasik , T. Waldmann , L. Fabbietti , T. Klemenz , L. Lautner , B. Ulukutlu

The Resistive Plate Chamber (RPC) is widely used in experiments of high energy physics as trigger detector as its good time resolution and high efficiency. In the traditional layout of RPC, the graphite layers are indispensable parts. The…

Instrumentation and Detectors · Physics 2021-08-31 Quanyin Li , Xiangyu Xie , Zhengwei Xue , Jiajin Ge , Yongjie Sun

A novel instrument has been developed to monitor and record the ambient pa- rameters such as temperature, atmospheric pressure and relative humidity. These parameters are very essential for understanding the characteristics such as gain of…

Instrumentation and Detectors · Physics 2015-07-15 S. Sahu , M. R. Bhuyan , Sharmili Rudra , S. Biswas , B. Mohanty , P. K. Sahu

The fast timing MPGD is a micro-pattern gaseous detector conceived for achieving sub-nanosecond time resolution while maintaining the ability to instrument large areas in high-rate environments; applications of such technology are…

Instrumentation and Detectors · Physics 2022-12-21 Antonello Pellecchia , Piet Verwilligen

A simple circuit for the presentation of the signals from Multi-gap Resistive Plate Chambers (MRPCs) to standard existing digitization electronics is described. The circuit is based on "off-the-shelf" discrete components. An optimization of…

Instrumentation and Detectors · Physics 2008-11-26 W. J. Llope , T. Nussbaum , G. Eppley , J. Velkovska , T. Chujo , S. Huang , B. Love , H. Valle , L. Ruan , Z. Xu , B. Bonner

Silicon microstrip detectors are widely used in experiments for space astronomy. Before the detector is assembled, extensive characterization of the silicon microstrip sensors is indispensable and challenging. This work electrically…

Instrumentation and Detectors · Physics 2021-03-29 Jia-Ju Wei , Jian-Hua Guo , Yi-Ming Hu

Performance demands for high and super-high luminosity at the LHC (up to 10^35 cm^(-2) sec^(-1) after the 2017 shutdown) and at future colliders demand high resolution tracking detectors with very fast time response and excellent temporal…

Instrumentation and Detectors · Physics 2016-11-18 Robert Ball , John W. Chapman , Erez Etzion , Peter S. Friedman , Daniel S. Levin , Meny Ben Moshe , Curtis Weaverdyck , Bing Zhou