Related papers: An improved design of spark-protected microstrip g…
We have demonstrated that small gap (0.1 to 0.4 mm) RPCs made of low resistivity materials (less than 1E8 Ohm.cm) can operate at counting rates of up to 1E5 Hz/mm2 with position resolutions better than 50 micrometer. Results of preliminary…
Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…
The applications of Resistive Plate Chambers (RPCs) have recently been extended by the development of counters with time resolution below 100 ps sigma for minimum ionising particles. Applications to HEP experiments have already taken place…
For modern Gas sensors, high sensitivity and low power are expected. This paper discusses design, simulation and fabrication of new Micromachined Thermal Converters (MTCs) based on GaAs developed for Gas sensors. Metal oxide gas sensors…
We have developed prototypes of GEM-like detectors with resistive electrodes to be used as RICH photodetectors equipped with CsI photocathodes. The main advantages of these detectors are their intrinsic spark protection and possibility to…
Crosstalk characteristics such as pulse amplitude and shape are studied with a simple PSpice model of the capacitive couplings within an MPGD. The crosstalk pulse shape can be understood as due to a CR-differentiator. Crosstalk can occur…
A quality assurance and performance qualification laboratory was built at McGill University for the Canadian-made small-strip Thin Gap Chamber (sTGC) muon detectors produced for the 2019-2020 ATLAS experiment muon spectrometer upgrade. The…
The Spherical Proportional Counter is a novel type of radiation detector, with a low energy threshold (typically below 100 eV) and good energy resolution. This detector is being developed by the network NEWS, which includes several…
Resistive-anode micromegas detectors are in development since several years, in an effort to solve the problem of sparks when working at high flux and high ionizing radiation like in the HL-LHC (up to ten times the luminosity of the LHC).…
Resistive Plate Chamber (RPC) is a well-known gaseous detector in the field of High Energy Physics (HEP) experiments for its good tracking capability, high efficiency, good time resolution, and low cost of fabrication. The main issue in RPC…
As demonstrated by the ATLAS New Small Wheel community with their MicroMegas (MM) design, resistive electrodes are now used in different detector types within the Micro Pattern Gaseous Detector family to improve their robustness or…
This work reviews various methods used to minimize the probability of discharge occurrence in MPGDs or to mitigate the effect of spark discharges on the detector system. These include techniques that can reduce the probability that the…
In recent years important progress in micropattern gaseous detectors has been achieved in the use of resistive material to build compact spark-protected devices. The novel idea presented here consists of the polarisation of WELL structures…
Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density…
This paper presents an electrolytically gated broadband microwave sensor where atomically-thin graphene layers are integrated into coplanar waveguides and coupled with microfluidic channels. The interaction between a solution under test and…
For a hadron calorimeter active element there is considered a gaseous secondary emis-sion detector (150 micron gap, 50 kV/cm). Such one-stage parallel plate chamber must be a radiation hard, fast and simple. A model of such detector has…
Many current and future nuclear physics (NP) experiments across the United States have and are implementing micro-pattern gas detectors (MPGDs) to be used for tracking and PID purposes. MPGDs are capable of operating in high rate…
The limitation of the detection rate of standard bakelite resistive plate chambers (RPC) used as muon detectors in the LHC experiments has prevented the use of such detectors in the high rate regions in both CMS and ATLAS detectors. One…
We have developed a new design of a GEM-like detector with single-layer electrodes made of a resistive kapton. This detector can operate at gains close to 10E5 even in pure Ar and Ne and if transited to discharges at higher gains they, due…
The Gas Electron Multiplier (GEM) detector is one of promising particle and radiation detectors that has been improved greatly from previous gas detectors. The improvement includes better spatial resolutions, higher detection rate…