Related papers: A 1 mm Scintillating Fibre Tracker Readout by a Mu…
We present prototype modules for a tracking detector consisting of multiple layers of 0.25 mm diameter scintillating fibers that are read out by linear arrays of silicon photomultipliers. The module production process is described and…
A novel modular high-resolution charged-particle tracking detector design using $250\mu m$ diameter, round, scintillating fibers and SiPM arrays for readout is presented. The fiber modules consist of 8 layers of 128 fibers, mechanically sta…
The performance of 16 and 64 channel photomultipliers coupled to scintillating fibres has been tested. The devices are sensitive to single photoelectrons, show little gain losses for magnetic fields up to 100 Gauss and have moderate optical…
The performance of a scintillating fiber detector prototype for tracking under high rate conditions is investigated. A spatial resolution of about100 micron is aimed for the detector. Further demands are low occupancy and radiation hardness…
We present a prototype for the first tracking detector consisting of 250 micron thin scintillating fibers and silicon photomultiplier (SiPM) arrays. The detector has a modular design, each module consists of a mechanical support structure…
Using thin scintillating fibers with Silicon Photomultiplier (SiPM) readout a mo dular high-resolution charged-particle tracking detector has been designed. The fiber modules consist of 2 x 5 layers of 128 round multiclad scintillating…
The results obtained in laboratory tests, using scintillator bars read by silicon photomultipliers are reported. The present approach is the first step for designing a precision tracking system to be placed inside a free magnetized volume…
Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons are increasingly being exploited for the non-destructive assay of shielded containers in a wide range of applications. One such application is the…
We report on the prototyping of a plastic scintillator hodoscope with wavelength-shifting fibre read-out by a multi-anode photomultiplier as part of the development of a detector for cosmic ray muons to be carried aboard an aircraft. Light…
We propose a new scintillator-based tracker concept based on a monolithic plastic scintillator plate with embedded scatterers and wavelength-shifting fiber readout. The embedded scatterers localize scintillation light so that channels…
Hamamatsu R5900-00-M64 and R7600-00-M64 photomultiplier tubes will be used with wavelength--shifting optical fibres to read out scintillator strips in the MINOS near detector. We report on measurements of the gain, efficiency, linearity,…
A fibre detector with multianode PM readout for high rate applications was developed for the HERA-B spectometer to cover the area near the beampipe. Such a detector has to operate at particle rates up to 2*10**4 mm**(-2) s**(-1) and has to…
A semiconductor tracker for muon scattering tomography is presented. The tracker contains silicon strip sensors with an $80\,\mu$m pitch, precision mechanics and integrated cooling. The electronic readout of the sensors is performed by a…
Cosmic-ray muons, owing to their high penetration power and abundance, have been widely employed as a natural probe in experimental particle physics. We developed a meter-scale cosmic-ray muon telescope, consisting of two parallel…
A tracking detector based on two meters long scintillating fibers read out by silicon photomultipliers (SiPM) is being developed for the Kaos spectrometer at the Mainz Microtron MAMI. Results from a prototype setup using 2 mm square fibers…
A prototype plastic scintillating fibre based beam profile monitor was tested at the Heidelberg Ion Therapy Centre / \textit{Heidelberg Ionenstrahl Therapiezentrum} (HIT) in 2016 to determine its beam property reconstruction performance and…
The performance of the $200\times2.5\times1$ cm$^3$ plastic scintillator strip with wavelength shifting fiber read-out by two novel photodetectors called Silicon PhotoMultipliers (SiPMs) is discussed. The advantages of SiPM relative to the…
Scintillating fibre detectors combine sub-mm resolution particle tracking, precise measurements of the particle stopping power and sub-ns time resolution. Typically, fibres are read out with silicon photomultipliers (SiPM). Hence, if fibres…
Plastic scintillators are widely used for the detection of elementary particles, and 3D reconstruction of particle tracks is achieved by segmenting the detector into 3D granular structures. In this study, we present a novel prototype…
Cosmic-ray muons are highly penetrative charged particles that are observed at sea level with a flux of approximately one per square centimetre per minute. They interact with matter primarily through Coulomb scattering, which is exploited…