Related papers: Fe XVII X-ray Line Ratios for Accurate Astrophysic…
Efforts to benchmark astrophysical observations with X-ray laboratory measurements have been stymied by observed and measured differences of up to a factor of two in the ratio '3s/3d' of Fe XVII lines at ~17 \AA and ~15 \AA respectively.…
We determined relative X-ray photon emission cross sections in Fe XVII ions that were mono-energetically excited in an electron beam ion trap. Line formation for the 3s (3s-2p) and 3d (3d-2p) transitions of interest proceeds through…
We review the accuracy of existing \ion{Fe}{17} X-ray line emission models by comparing them with an extensive analysis of \textit{Chandra} high energy transmission grating (HETG) observations of stellar coronae. We find significant…
New theoretical results from large-scale relativistic close coupling calculations reveal the precise effect of resonances in collisional excitation of x-ray lines of Ne-like Fe XVII. Employing the Breit-Pauli R-matrix method and a 89-level…
Recent state-of-the-art calculations of A-values and electron impact excitation rates for Fe III are used in conjunction with the Cloudy modeling code to derive emission line intensity ratios for optical transitions among the fine-structure…
We present a review of two methods used to model recent LCLS experimental results for the 3C/3D line intensity ratio of Fe XVII (Bernitt et al. 2012), the time-dependent collisional-radiative method and the density-matrix approach. These…
Theoretical electron density-sensitive line ratios $R_1 - R_6$ of Ar XIV soft X-ray emission lines are presented. We found that these line ratios are sensitive to electron density $n_e$, and the ratio $R_1$ is insensitive to electron…
Recent fully relativistic calculations of radiative rates and electron impact excitation cross sections for Fe {\sc xiii} are used to generate emission-line ratios involving 3s$^{2}$3p$^{2}$--3s3p$^{3}$ and 3s$^{2}$3p$^{2}$--3s$^{2}$3p3d…
We improve by a factor of 4-20 the energy accuracy of the strongest soft X-ray transitions of Fe XVII ions by resonantly exciting them in an electron beam ion trap with a monochromatic beam at the P04 beamline of the PETRA III synchrotron…
One of the most enduring and intensively studied problems of X-ray astronomy is the disagreement of state-of-the art theory and observations for the intensity ratio of two Fe XVII transitions of crucial value for plasma diagnostics, dubbed…
We show that the Fe XVII I(17.10 A)/I(17.05 A) line ratio observed in the Chandra HETG spectrum of the intermediate polar EX Hydrae is significantly smaller than that observed in the Sun or other late-type stars. Using the Livermore X-ray…
The accuracy of dielectronic recombination (DR) data for astrophysics related ions plays a key role in astrophysical plasma modeling. The measurement of the absolute DR rate coefficient of Fe17+ ions was performed at the main cooler storage…
Line intensities and oscillator strengths for the controversial 3C and 3D astrophysically relevant lines in neonlike Fe${}^{16+}$ ions are calculated. We show that, for strong x-ray sources, the modeling of the spectral lines by a peak with…
The theoretical intensities of the soft X-ray Fe XVII lines arising from 2l-3l' transitions are reexamined using a three-ion collisional-radiative model that includes the contributions to line formation of radiative recombination (RR),…
Fully relativistic calculations of radiative rates and electron impact excitation cross sections for Fe X are used to derive theoretical emission-line ratios involving transitions in the 174-366 A wavelength range. A comparison of these…
We have used an electron beam ion trap to measure electron-density-diagnostic line-intensity ratios for extreme ultraviolet lines from F XII, XIII, and XIV at wavelengths of 185-205 255-276 Angstroms. These ratios can be used as density…
For more than 40 years, most astrophysical observations and laboratory studies of two key soft x-ray diagnostic $2p-3d$ transitions, $3C$ and $3D$, in Fe XVII ions found oscillator strength ratios $f(3C)/f(3D)$ disagreeing with theory, but…
Line ratio of $3d-2p$ transition lines in boron-like spectra of Si X, S XII, Ar XIV and Fe XXII has been investigated. Collisional-radiative model calculations reveal that the line ratio is sensitive to the electron density in ranges of…
Aims: We generate theoretical ultraviolet and extreme-ultraviolet emission line ratios for O IV and show their strong versatility as electron temperature and density diagnostics for astrophysical plasmas. Methods: Recent fully relativistic…
Theoretical emission-line ratios involving Fe XI transitions in the 257-407 A wavelength range are derived using fully relativistic calculations of radiative rates and electron impact excitation cross sections. These are subsequently…