We describe a feasible implementation of a novel X-ray detector for highly energetic x-ray photons with a large solid angle coverage, optimal for the detection of Compton x-ray scattered photons. The device consists of a 20~cm-thick…
Compton scattering of a laser beam with a relativistic electron beam has been used to generate intense, highly polarized and nearly monoenergetic x-ray or gamma-ray beams at many facilities. The ability to predict the spatial, spectral and…
Study of high energy cosmic events in the MeV range requires detector with high efficiency and energy resolution to be constructed. The present setup consisting of scintillator crystals CeBr3 with different thickness, each coupled with 12 x…
Quasi-monochromatic, high energy and highly polarized $\gamma$-ray beam sources based on Compton scattering of laser photons (LCS) on relativistic electrons have developed for the last few decades as established instruments for nuclear…
The rapid development of X-ray astronomy has been made possible by widely deploying X-ray focusing telescopes on board many X-ray satellites. Geant4 is a very powerful toolkit for Monte Carlo simulations and has remarkable abilities to…
Several models for the simulation of photon elastic scattering are quantitatively evaluated with respect to a large collection of experimental data retrieved from the literature. They include models based on the form factor approximation,…
In this paper we present a method of scintillation detector energy calibration using the gamma-rays. The technique is based on the Compton scattering of gamma-rays in a scintillation detector and subsequent photoelectric absorption of the…
The bremsstrahlung spectra produced by electrons impinging on thick targets are simulated using the Geant4 Monte Carlo toolkit. Simulations are validated against experimental data available in literature for a range of energy between 0.5…
Our interest has been to study the effect that scattered radiation has on contrast, signal-to-noise ratio and thickness reconstruction in digital mammographies. Using the GEANT code we have performed Monte-Carlo simulations of 25 kVp Mo/Mo…
Gamma-ray spectroscopy provides diagnostics of particle acceleration in solar flares, but care must be taken when interpreting the spectra due to effects of the angular distribution of the accelerated particles (such as relativistic…
Imaging of nuclear gamma-ray lines in the 1-10 MeV range is far from being established in both medical and physical applications. In proton therapy, 4.4 MeV gamma rays are emitted from the excited nucleus of either 12^C^* or 11^B^* and are…
X-ray fluorescence computed tomography based on sheet-beam can save a huge amount of time to obtain a whole set of projections using synchrotron. However, it is clearly unpractical for most biomedical research laboratories. In this paper,…
The Monte Carlo method is widely used in the Gamma Knife dose distribution calculations. In this study, Monte-Carlo simulation with Geant4 was applied to determine Leksell Gamma Knife dose distribution for homogeneous solid water and…
Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $\gamma$-rays…
For long time non-pure beta emitters are avoided from PET imaging due to extra dose and increase in background from Compton scattering. But advent of high-resolution Compton camera system opens up new domain of imaging. Various non-pure…
By considering the effect of varying the target radii and detector aperture width on the scattering angle in experimental Compton scattering, mathematical models were developed and subsequently incorporated into Monte Carlo simulations. By…
Nowadays, the current threat of international terrorism is set to a severe level, demanding worldwide enhanced security. Radioactive materials that could be fashioned into a radiation dispersal device typically emit gamma rays, while…
We present a Monte Carlo collisional scheme that models single Compton scattering between leptons and photons in particle-in-cell codes. The numerical implementation of Compton scattering can deal with macro-particles of different weights…
A proton pencil beam is associated with a surrounding low-dose envelope, originating from nuclear interactions. It is important for treatment planning systems to accurately model this envelope when performing dose calculations for pencil…
In this work we present a novel 3D Monte Carlo photon transport program for simulation of multiple refractive scattering based on the refractive properties of X-rays in highly scattering media, like lung tissue. Multiple scattering reduces…