English
Related papers

Related papers: Monte Carlo study of a 3D Compton imaging device w…

200 papers

Low-energy background through Compton scattering from the ambient $\gamma$ rays can be contaminated in direct dark matter search experiments. In this paper, we report comparable measurements on low-energy spectra via Compton scattering from…

Instrumentation and Detectors · Physics 2023-04-26 J. W. Hu , L. T. Yang , Q. Yue , X. P. Geng , H. B. Li , Y. F. Liang , S. T. Lin , S. K. Liu , H. Ma , L. Wang , H. T. Wong , B. T. Zhang

Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT 4…

Instrumentation and Detectors · Physics 2009-11-10 D. Lazaro , I. Buvat , G. Loudos , D. Strul , G. Santin , N. Giokaris , D. Donnarieix , L. Maigne , V. Spanoudaki , S. Styliaris , S. Staelens , V. Breton

A high sensitivity Cardiac SPECT system using curved crystals with pinhole collimation was proposed previously (Dey, IEEE TNS 2012, Bhusal et al, Med. Phys. 2019). Here, we hypothesize that a high curvature hemi-ellipsoid detector results…

Instrumentation and Detectors · Physics 2022-05-24 Hanif R. Soysal , J. Dey , W. P. Donahue , K. L. Matthews

Monte Carlo simulation is one of the best tools to study the complex spectra of Compton-thick AGNs and to figure out the relation between their nuclear structures and X-ray spectra. We have simulated X-ray spectra of Compton-thick AGNs…

Astrophysics · Physics 2009-11-13 Shinya Ikeda , Hisamitsu Awaki , Yuichi Terashima

A version of Geant4 has been developed to treat high-energy proton radiography. This article presents the results of calculations simulating the effects of nuclear elastic scattering for various test step wedges. Comparisons with…

Instrumentation and Detectors · Physics 2014-09-19 Xu Haibo , Zheng Na

Modern PET systems reach a spatial resolution of 3-10 mm. A disadvantage of this technique is the diffusion of the positron before its decay with a typical range of ca. 1 mm (depending on its energy). This motion and Compton scattering of…

Instrumentation and Detectors · Physics 2012-02-03 C. Lang , D. Habs , P. G. Thirolf , A. Zoglauer

In X-ray imaging, photons are transmitted through and absorbed by the subject, but are also scattered in significant quantities. Previous attempts to use scattered photons for biological imaging used pencil or fan beam illumination. Here we…

The high scintillation luminosity of n-type GaAs at 10K is surprising because (1) with a refractive index of about 3.5, escape is inhibited by total internal reflection and (2) narrow-beam experiments at 90K report infrared absorption…

Instrumentation and Detectors · Physics 2022-06-01 Stephen Derenzo

The imaging performance of a high-resolution preclinical microPET system employing liquid xenon as the gamma ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection…

Medical Physics · Physics 2012-03-23 A. Miceli , J. Glister , A. Andreyev , D. Bryman , L. Kurchaninov , P. Lu , A. Muennich , F. Retiere , V. Sossi

Novel radiotherapy techniques like synchrotron X-ray microbeam radiation therapy (MRT), require fast dose distribution predictions that are accurate at the sub-mm level, especially close to tissue/bone/air interfaces. Monte Carlo physics…

In this study, the absorbed dose calculation for the cerebral region is refined using the Geant4 software, along with the ROOT and GATE programs. This approach provides a detailed statistical analysis of positron trajectories within a water…

Medical Physics · Physics 2025-05-06 Walter Sabalza-Castillejo , Miguel Martin-Landrove

Monte Carlo simulations are powerful tools for understanding the effects of radiation interactions within detector devices allowing not only to evaluate typical estimates for experimental measurements and to serve as means for designing…

Instrumentation and Detectors · Physics 2016-02-09 F. Marinho , K. Akiba

A Compton camera is the most promising approach for gamma-ray detection in the energy region from several hundred keV to MeV, especially for application in high energy astrophysics. In order to obtain good angular resolution, semiconductor…

The use of GEANT4 code has increased in the medical field. There are various studies to calculate the patient dose distributions with the GEANT4 code using the imaging data. In present study, the Monte Carlo simulations based on the DICOM…

Medical Physics · Physics 2015-03-18 JeongOk Lee , JeongKu Kang , JhinKee Kim , HyeongCheol Kwon , JungSoo Kim , BuGil Kim , DongHyeok Jeong

The cross section of atomic electron Compton scattering $\gamma + e \rightarrow \gamma^\prime + e^\prime $ was measured in the 4.40--5.475 GeV photon beam energy region by the {\em PrimEx} collaboration at Jefferson Lab with an accuracy of…

In computed tomography (CT) reconstruction, scattering causes server quality degradation of the reconstructed CT images by introducing streaks and cupping artifacts which reduce the detectability of low contrast objects. Monte Carlo (MC)…

Image and Video Processing · Electrical Eng. & Systems 2022-02-01 Ammar Alsaffar , Steffen Kieß , Kaicong Sun , Sven Simon

UCGretina, a GEANT4 simulation of the GRETINA gamma-ray tracking array of highly-segmented high-purity germanium detectors is described. We have developed a model of the array, in particular of the Quad Module and the capsules, that gives…

In this study, we employ the Monte Carlo simulations by using the GEANT4 code to demonstrate the capability of muon tomography based on the dual-parameter analysis in the examination of the nuclear waste barrels. Our current hodoscope setup…

Instrumentation and Detectors · Physics 2022-12-06 Ahmet Ilker Topuz , Madis Kiisk , Andrea Giammanco

Computer simulations of photon transport through an absorbing and/or scattering medium form an important research tool in astrophysics. Nearly all software codes performing such simulations for three-dimensional geometries employ the Monte…

Instrumentation and Methods for Astrophysics · Physics 2018-07-25 Peter Camps , Maarten Baes

In this work, the simulation of optical photons is carried out in an antineutrino detector module consisting of a plastic scintillator connected to light guides and photomultipliers on both ends, which is considered to be used for remote…

Instrumentation and Detectors · Physics 2018-05-23 Mustafa Kandemir , Altan Cakir