English
Related papers

Related papers: Liquid Xenon Detectors for Positron Emission Tomog…

200 papers

Recent studies of positron emission tomography (PET) devices have shown that the detection of polarization-correlated annihilation quanta can potentially reduce the background and creation of false lines of response (LORs) leading to…

J-PET is a photon detector built of plastic scintillators, which already has been commissioned for CPT studies in the decays of positronium. In the first experiment, J-PET has achieved a sensitivity to CPT violation at a level of 10^{-4},…

High Energy Physics - Phenomenology · Physics 2023-02-28 Neha Chug , Aleksander Gajos

The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter…

Possibility to use ultra pure liquid Xenon as a low energy solar neutrino detector by means of $\nu$+e scatterings is evaluated. A possible detector with 10 tons of fiducial volume will give $\sim$14 events for pp-neutrinos and $\sim$6…

High Energy Physics - Phenomenology · Physics 2017-08-23 Y. Suzuki

Accurate quantification in positron emission tomography (PET) is essential for accurate diagnostic results and effective treatment tracking. A major issue encountered in PET imaging is attenuation. Attenuation refers to the diminution of…

A new type of detector for positron-emission tomography (PET) has been proposed recently, using a heavy organo-metallic liquid - TriMethyl Bismuth (TMBi) - as target material. TMBi is a transparent liquid with the high Z element Bismuth…

Instrumentation and Detectors · Physics 2023-01-12 S. Peters , B. Gerke , V. Hannen , C. Huhmann , N. Marquardt , K. Schäfers , D. Yvon , V. Sharyy , C. Weinheimer

Positron Emission Tomography (PET) is an imaging technique which can be used to investigate chemical changes in human biological processes such as cancer development or neurochemical reactions. Most dynamic PET scans are currently analyzed…

Applications · Statistics 2014-11-11 Ci-Ren Jiang , John A D Aston , Jane-Ling Wang

Xenon time projection chambers (TPCs) have become a well-established detection technology for neutrinoless double beta decay searches in $^{136}$Xe. I discuss the motivations for this choice. I describe the status and prospects of both…

Instrumentation and Detectors · Physics 2019-04-16 Michel Sorel

The precise measurements of the Compton scatterings of photons originating from the decay of positronium atoms can reveal information about their polarizations. J-PET detector is constructed of 192 plastic scintillators and is unique to…

Instrumentation and Detectors · Physics 2020-01-29 Sushil K. Sharma , Nikodem Krawczyk , Juhi Raj

We present a detector apparatus, DireXeno (DIRectinal Xenon), designed to measure the spatial and temporal properties of scintillation in liquid xenon to very high accuracy. The properties of scintillation are of primary importance for dark…

Instrumentation and Detectors · Physics 2020-06-17 R. Itay , P. Z. Szabo , G. Koltman , M. M. Devi , M. Shutman , H. Landsman , R. Budnik

Dual phase Xenon Time Projection Chambers (XeTPCs) are being used by several experiments as a promising technique for direct detection of dark matter. We report on the design and performance of a small 3-D sensitive dual phase XeTPC. The…

Instrumentation and Detectors · Physics 2015-06-17 Qing Lin , Yuehuan Wei , Jie Bao , Jie Hu , Xinran Li , Wolfgang Lorenzon , Kaixuan Ni , Michael Schubnell , Mengjiao Xiao , Xiang Xiao

Study of certain angular correlations in the three-photon annihilations of the triplet state of positronium, the electron-positron bound state, may be used as a probe of potential CP and CPT-violating effects in the leptonic sector. We…

Instrumentation and Detectors · Physics 2020-06-02 Aleksander Gajos

NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to approximately 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search…

Instrumentation and Detectors · Physics 2026-01-13 NEXT Collaboration , M. Pérez Maneiro , M. Martínez-Vara , S. Torelli , G. Martínez-Lema , P. Novella , J. A. Hernando Morata , J. J. Gómez-Cadenas , C. Adams , H. Almazán , V. Álvarez , A. I. Aranburu , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , Y. Ayyad , C. D. R. Azevedo , K. Bailey , F. Ballester , J. E. Barcelon , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , A. Brodoline , N. Byrnes , A. Castillo , E. Church , L. Cid , M. Cid , X. Cid , C. A. N. Conde , C. Cortes-Parra , F. P. Cossío , R. Coupe , E. Dey , P. Dietz , C. Echeverria , M. Elorza , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , F. W. Foss , Z. Freixa , J. García-Barrena , J. W. R. Grocott , R. Guenette , J. Hauptman , C. A. O. Henriques , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , Y. Ifergan , A. F. B. Isabel , B. J. P. Jones , F. Kellerer , L. Larizgoitia , A. Larumbe , F. Lopez , N. López-March , R. Madigan , R. D. P. Mano , A. Marauri , A. P. Marques , J. Martín-Albo , A. Martínez , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , K. E. Navarro , D. R. Nygren , E. Oblak , J. Palacio , B. Palmeiro , I. Parmaksiz , A. Pazos , J. Pelegrin , M. Querol , J. Renner , I. Rivilla , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , E. Ruiz-Chóliz , P. Saharia , F. P. Santos , J. M. F. dos Santos , M. Seemann , I. Shomroni , A. L. M. Silva , P. A. O. C. Silva , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , S. Teruel-Pardo , J. F. Toledo , C. Tonnelé , J. Torrent , A. Trettin , P. R. G. Valle , M. Vanga , P. Vázquez Cabaleiro , J. F. C. A. Veloso , J. D. Villamil , J. Waiton , A. Yubero-Navarro

Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes…

Image and Video Processing · Electrical Eng. & Systems 2024-04-18 Shaoyan Pan , Elham Abouei , Junbo Peng , Joshua Qian , Jacob F Wynne , Tonghe Wang , Chih-Wei Chang , Justin Roper , Jonathon A Nye , Hui Mao , Xiaofeng Yang

The positron-electron pair annihilation in two photons is known for its numerous applications using PET scanners. The decay of Positronium (Ps) from a standard sealed source in more than two photons is less likely but can be observed with a…

Physics Education · Physics 2011-09-20 M. E. A. Elbasher , W. Erasmus , E. A. M. Khaleel , J. Ndayishimye , P. Papka

A detection system of the conventional PET tomograph is set-up to record data from e+ e- annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the…

Particle beams focused to micrometer-sized spots play a crucial role in forefront research using low-energy positrons. Their expedient and wide application, however, requires highly-resolved, fast beam diagnostics. We have developed two…

We describe a feasible implementation of a novel X-ray detector for highly energetic x-ray photons with a large solid angle coverage, optimal for the detection of Compton x-ray scattered photons. The device consists of a 20~cm-thick…

Instrumentation and Detectors · Physics 2022-01-27 Ángela Saá Hernández , Diego González-Díaz , Pablo Villanueva , Carlos Azevedo , Marcos Seoane

Transforming the resistive plate chambers from charged-particle into gamma-quanta detectors opens the way towards their application as a basic element of a hybrid imaging system, which combines positron emission tomography (PET) with…

Instrumentation and Detectors · Physics 2015-06-12 Georgi Georgiev , Nevena Ilieva , Venelin Kozhuharov , Iglika Lessigiarska , Leandar Litov , Borislav Pavlov , Peicho Petkov