Related papers: The SiRi Particle-Telescope System
A new detection system KRATTA, Krak\'ow Triple Telescope Array, is presented. This versatile, low threshold, broad energy range system has been built to measure the energy, emission angle, and isotopic composition of light charged reaction…
Two types of wedge-shaped CsI(Tl)s were designed to be placed behind the annular double-sided silicon detectors (ADSSDs) to identify the light charged particles with the $\Delta E-E$ method. The properties of CsI(Tl)s with different shapes…
We report on an ion-optical system that serves as a microscope for ultracold ground state and Rydberg atoms. The system is designed to achieve a magnification of up to 1000 and a spatial resolution in the 100 nm range, thereby surpassing…
We developed a beam telescope system comprising five layers of 300-$\mu$m-thick INTPIX4NA monolithic pixel sensors with each pixel size of 17 $\mu$m square. The sensors were fabricated using silicon-on-insulator (SOI) technology. The…
Primary gamma-ray spectra for a wide excitation-energy range have been extracted for 44Ti from particle-gamma coincidence data of the 46Ti(p,t gamma)44Ti reaction. These spectra reveal information on the gamma-decay pattern of the nucleus,…
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current…
The light yield of a small undoped cesium iodide (CsI) crystal directly coupled with two silicon photomultipliers (SiPMs) at about 77~Kelvin was measured to be $43.0 \pm 1.1$~photoelectrons (PE) per keV electron-equivalent (keV$_\text{ee}$)…
The SiD Detector is one of two validated detector designs for the future International Linear Collider. SiD features a compact, cost-constrained design for precision Higgs couplings determination, and other measurements, and sensitivity to…
A NaI(Tl) detector array called DALI2 (Detector Array for Low Intensity radiation 2) has been constructed for in-beam $\gamma$-ray spectroscopy experiments with fast radioactive isotope (RI) beams. It consists typically of 186 NaI(Tl)…
The full instrument response of a superminiaturised CsI(Tl)-PiN photodiode radioactivity detector, intended for deployment on a meteorological radiosonde, has been modelled by combining a physics-based model of the sensor with the detector…
The Planetary Systems Imager (PSI) is a proposed instrument for the Thirty Meter Telescope (TMT) that provides an extreme adaptive optics (AO) correction to a multi-wavelength instrument suite optimized for high contrast science. PSI's…
In beam test experiments have been carried out for particle identification using digital pulse shape analysis in a 500~$\mu$m thick Neutron Transmutation Doped (nTD) silicon detector with an indigenously developed FPGA based 12 bit…
A telescope of three silicon detectors has been installed close to the internal target position of the ANKE spectrometer, which is situated inside the ultra-high vacuum of the COSY-Juelich light-ion storage ring. The detection and…
An array of Parallel Plate Avalanche Counters (PPAC) for the detection of heavy ions has been developed. The new device, NIFF (Nuclear Instrument for Fission Fragments), consists of four individual detectors and covers $60\%$ of 2$\pi$. It…
The level density and gamma-ray strength function of 45Ti have been determined by use of the Oslo method. The particle-gamma coincidences from the 46Ti(p,d gamma)45Ti pick-up reaction with 32 MeV protons are utilized to obtain gamma-ray…
We report on the scintillation characterization of a 1 cm^3 CsI(Tl) crystal coupled to a 6 x 6 mm^2 SiPM read out with a custom transimpedance amplifier at cryogenic temperatures. The crystal was prepared with optical-grade surfaces and…
The optical truss interferometer (OTI) is a contingent subsystem proposed for the LISA telescopes to aid in the verification of a $1 \frac{\mathrm{pm}}{\sqrt{\mathrm{Hz}}}$ optical path length stability. Each telescope would be equipped…
Scintillating crystal detector may offer some potential advantages in the low-energy, low-background experiments. A 500 kg CsI(Tl) detector to be placed near the core of Nuclear Power Station II in Taiwan is being constructed for the…
This letter explains a new, highly sensitive method for the detection of neutrons, which uses the T$_{1/2}=845$ ns delay in the decay of $^{128}$I at the 137.8 keV energy level, resulting from the capture of thermal neutrons by iodine…
MIDAS (MIcrostrip Detector Array System) is a compact silicon tracking telescope for charged particles emitted at small angles in intermediate energy photonuclear reactions. It was realized to increase the angular acceptance of the DAPHNE…