The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the…
Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20 keV energy range. We are building a TES-based instrument for the…
Capacitive-coupled Low-Gain Avalanche Diode (AC-LGAD) sensors are being developed for high-energy particle physics experiments as a detector which provides fast time information with fine spatial resolution. This paper describes…
In this article we describe the photon detection readout electronics for the nEDM@SNS experiment. The chosen "photon counting" architecture, which utilizes high-efficiency silicon photomultipliers (SiPMs) and is appropriate for low-light…
Semiconductor avalanche photodiodes (APDs) are commonly used for single photon detection in quantum key distribution. Recently, many attacks using bright illumination have been proposed to manipulate gated InGaAs APDs. In order to devise…
Small-pitch 3D silicon pixel detectors have been investigated as radiation-hard candidates for the innermost layers of the HL-LHC pixel detector upgrades. Prototype 3D sensors with pixel sizes of 50$\times$50 and 25$\times$100 $\mu$m$^{2}$…
In this paper we report the experimental study of high-pressure xenon used as a scintillator, in the context of developing a gamma ray detector. We measure a light yield near 2 photoelectrons per keV for xenon at 40 bar. Together with the…
The detection of photons above 10 keV through MeV and GeV energies is challenging due to the penetrating nature of the radiation, which can require large detector volumes, resulting in correspondingly high background. In this energy range,…
Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. While this background negatively impacts detector performance in…
We report on the first observation of electroluminescence and charge amplification with a Virtual Cathode Chamber (VCC) microstrips plate immersed in liquid xenon. Both were observed in an intense non-uniform electric field in the vicinity…
A sensitive photoacoustic detection approach employing a silicon cantilever is investigated for power measurement of electromagnetic radiation. The technique which is actuated by pressure waves generated through radiation-induced heat,…
We extend the study of the performance of a prototype two-phase liquid xenon WIMP dark matter detector to recoil energies below 20 keV. We demonstrate a new method for obtaining the best estimate of the energies of events using a calibrated…
We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on…
3D silicon pixel detectors have been investigated as radiation-hard candidates for the innermost layers of the HL-LHC upgrade of the ATLAS pixel detector. 3D detectors are already in use today in the ATLAS IBL and AFP experiments. These are…
Detectors that can resolve photon number are needed in many quantum information technologies. In order to be useful in quantum information processing, such detectors should be simple, easy to use, and be scalable to resolve any number of…
The response of Low Gain Avalanche Diodes (LGADs), which are a type of thin silicon detector with internal gain, to X-rays of energies between 6-70 keV was characterized at the SLAC light source (SSRL). The utilized beamline at SSRL was…
We describe a novel photon detector which operates under an intense flux of neutrons. It is composed of lead-aerogel sandwich counter modules. Its salient features are high photon detection efficiency and blindness to neutrons. As a result…
This article reviews recent research for development of sensitive graphene photon detectors in the infrared/far infrared/THz range. For this range, graphene has promising potential in thermal photon detectors. Graphene has ultra-small…
We review the current status of liquid noble gas radiation detectors with energy threshold in the keV range, wich are of interest for direct dark matter searches, measurement of coherent neutrino scattering and other low energy particle…