English
Related papers

Related papers: The Online Calibration, Operation, and Performance…

200 papers

The CMS silicon tracker consists of two tracking devices utilizing semiconductor technology: the inner pixel and the outer strip detectors. They operate in a high-occupancy and high-radiation environment presented by particle collisions in…

Instrumentation and Detectors · Physics 2019-08-13 Viktor Veszpremi

The Pixel Luminosity Telescope is a silicon pixel detector dedicated to luminosity measurement at the CMS experiment at the LHC. It is located approximately 1.75 m from the interaction point and arranged into 16 "telescopes", with eight…

Instrumentation and Detectors · Physics 2023-08-02 Paul Lujan

In the first LHC running period the CMS-pixel detector had to face various operational challenges and had to adapt to the rapidly changing beam conditions. In order to maximize the physics potential and the quality of the data, online and…

Instrumentation and Detectors · Physics 2015-06-11 János Karancsi

The current CMS silicon pixel detector as the innermost component of the CMS experiment is performing well at LHC design luminosity, but would be subject to severe inefficiencies at LHC peak luminosities of 2x10e34 cm^-2 s^-1. Therefore, an…

Instrumentation and Detectors · Physics 2015-05-15 Simon Spannagel

The CMS collaboration is building a new inner tracking pixel detector for the High-Luminosity LHC. Each pixel readout chip will be controlled with a single serial input stream at 160 Mbps and will send out data via four current mode logic…

Instrumentation and Detectors · Physics 2022-09-07 Caleb Smith

The CMS tracker consists of two tracking systems utilizing semiconductor technology: the inner pixel and the outer strip detectors. The tracker detectors occupy the volume around the beam interaction region between 3 cm and 110 cm in radius…

Instrumentation and Detectors · Physics 2018-01-10 Viktor Veszpremi

A new pixel detector for the CMS experiment is being built, owing to the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking while featuring a significantly…

Instrumentation and Detectors · Physics 2016-12-23 Simon Spannagel

The CMS experiment will include a pixel detector for pattern recognition and vertexing. It will consist of three barrel layers and two endcaps on each side, providing three space-points up to a pseudoraditity of 2.1. Taking into account the…

Instrumentation and Detectors · Physics 2009-11-11 R. Horisberger , D. Kotlinski , T. Rohe

The phase 1 upgrade of the CMS pixel detector has been designed to maintain the tracking performance at instantaneous luminosities of $2 \times 10^{34} \mathrm{~cm}^{-2} \mathrm{~s}^{-1}$. Both barrel and endcap disk systems now feature one…

Instrumentation and Detectors · Physics 2018-07-25 Jory Sonneveld

The Phase-1 upgrade of the CMS pixel detector is built out of four barrel layers (BPix) and three forward disks in each endcap (FPix). It comprises a total of 124M pixel channels in 1,856 modules, and it is designed to withstand…

Instrumentation and Detectors · Physics 2017-10-02 Weinan Si

The readout chip for the CMS pixel detector has to deal with an enormous data rate. On-chip zero suppression is inevitable and hit data must be buffered locally during the latency of the first level trigger. Dead-time must be kept at a…

Instrumentation and Detectors · Physics 2009-11-11 H. Chr. Kaestli , M. Barbero , W. Erdmann , Ch. Hoermann , R. Horisberger , D. Kotlinski , B. Meier

The ATLAS Pixel detector is a high-resolution, low-noise silicon-based device designed to provide tracking and vertexing information within a distance of 12 cm from the LHC beam axis. It consists of approximately 80 million pixel channels…

Instrumentation and Detectors · Physics 2019-08-13 J. Biesiada

Swift, high resolution CMOS pixel sensors are being developed for the ILC vertex detector, aiming to allow approaching the interaction point very closely. A major issue is the time resolution of the sensors needed to deal with the high…

The CMS experiment at the LHC includes a hybrid silicon pixel detector for the reconstruction of charged tracks and of the interaction vertices. The detector is made of three barrel layers and two disks at each end of the barrel. Detector…

Instrumentation and Detectors · Physics 2007-10-29 Vincenzo Chiochia

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget…

Instrumentation and Detectors · Physics 2017-06-02 M. Dragicevic , M. Friedl , J. Hrubec , H. Steininger , A. Gädda , J. Härkönen , T. Lampén , P. Luukka , T. Peltola , E. Tuominen , E. Tuovinen , A. Winkler , P. Eerola , T. Tuuva , G. Baulieu , G. Boudoul , L. Caponetto , C. Combaret , D. Contardo , T. Dupasquier , G. Gallbit , N. Lumb , L. Mirabito , S. Perries , M. Vander Donckt , S. Viret , C. Bonnin , L. Charles , L. Gross , J. Hosselet , D. Tromson , L. Feld , W. Karpinski , K. Klein , M. Lipinski , G. Pierschel , M. Preuten , M. Rauch , M. Wlochal , M. Aldaya , C. Asawatangtrakuldee , K. Beernaert , D. Bertsche , C. Contreras-Campana , G. Eckerlin , D. Eckstein , T. Eichhorn , E. Gallo , J. Garay Garcia , K. Hansen , M. Haranko , A. Harb , J. Hauk , J. Keaveney , A. Kalogeropoulos , C. Kleinwort , W. Lohmann , R. Mankel , H. Maser , G. Mittag , C. Muhl , A. Mussgiller , D. Pitzl , O. Reichelt , M. Savitskyi , P. Schütze , V. Sola , S. Spannagel , R. Walsh , A. Zuber , H. Biskop , P. Buhmann , M. Centis-Vignali , E. Garutti , J. Haller , M. Hoffmann , R. Klanner , T. Lapsien , M. Matysek , A. Perieanu , Ch. Scharf , P. Schleper , A. Schmidt , J. Schwandt , J. Sonneveld , G. Steinbrück , B. Vormwald , J. Wellhausen , M. Abbas , C. Amstutz , T. Barvich , Ch. Barth , F. Boegelspacher , W. De Boer , E. Butz , M. Casele , F. Colombo , A. Dierlamm , B. Freund , F. Hartmann , S. Heindl , U. Husemann , A. Kornmeyer , S. Kudella , Th. Muller , H. J. Simonis , P. Steck , M. Weber , Th. Weiler , T. Kiss , F. Siklér , T. Tölyhi , V. Veszprémi , P. Cariola , D. Creanza , M. De Palma , G. De Robertis , L. Fiore , M. Franco , F. Loddo , G. Sala , L. Silvestris , G. Maggi , S. My , G. Selvaggi , S. Albergo , G. Cappello , S. Costa , A. Di Mattia , F. Giordano , R. Potenza , M. A. Saizu , A. Tricomi , C. Tuve , E. Focardi , M. E. Dinardo , S. Fiorendi , S. Gennai , S. Malvezzi , R. A. Manzoni , D. Menasce , L. Moroni , D. Pedrini , P. Azzi , N. Bacchetta , D. Bisello , M. Dall'Osso , N. Pozzobon , M. Tosi , L. Alunni Solestizi , M. Biasini , G. M. Bilei , C. Cecchi , B. Checcucci , D. Ciangottini , L. Fanò , C. Gentsos , M. Ionica , R. Leonardi , E. Manoni , G. Mantovani , S. Marconi , V. Mariani , M. Menichelli , A. Modak , A. Morozzi , F. Moscatelli , D. Passeri , P. Placidi , V. Postolache , A. Rossi , A. Saha , A. Santocchia , L. Storchi , D. Spiga , K. Androsov , P. Azzurri , G. Bagliesi , A. Basti , T. Boccali , L. Borrello , F. Bosi , R. Castaldi , M. Ceccanti , M. A. Ciocci , R. Dell'Orso , S. Donato , G. Fedi , A. Giassi , M. T. Grippo , F. Ligabue , G. Magazzu , P. Mammini , F. Mariani , E. Mazzoni , A. Messineo , A. Moggi , F. Morsani , F. Palla , F. Palmonari , A. Profeti , F. Raffaelli , A. Ragonesi , A. Rizzi , A. Soldani , P. Spagnolo , R. Tenchini , G. Tonelli , A. Venturi , P. G. Verdini , D. Abbaneo , I. Ahmed , E. Albert , G. Auzinger , G. Berruti , J. Bonnaud , J. Daguin , A. D'Auria , S. Detraz , O. Dondelewski , B. Engegaard , F. Faccio , N. Frank , K. Gill , A. Honma , A. Kornmayer , A. Labaza , F. Manolescu , I. McGill , S. Mersi , S. Michelis , A. Onnela , M. Ostrega , S. Pavis , A. Peisert , J. -F. Pernot , P. Petagna , H. Postema , K. Rapacz , C. Sigaud , P. Tropea , J. Troska , A. Tsirou , F. Vasey , B. Verlaat , P. Vichoudis , L. Zwalinski , F. Bachmair , R. Becker , D. di Calafiori , B. Casal , P. Berger , L. Djambazov , M. Donega , C. Grab , D. Hits , J. Hoss , G. Kasieczka , W. Lustermann , B. Mangano , M. Marionneau , P. Martinez Ruiz del Arbol , M. Masciovecchio , M. Meinhard , L. Perozzi , U. Roeser , A. Starodumov , V. Tavolaro , R. Wallny , D. Zhu , K. Bösiger , L. Caminada , F. Canelli , V. Chiochia , A. de Cosa , C. Galloni , T. Hreus , B. Kilminster , C. Lange , R. Maier , J. Ngadiuba , D. Pinna , P. Robmann , S. Taroni , Y. Yang , W. Bertl , K. Deiters , W. Erdmann , R. Horisberger , H. -C. Kaestli , D. Kotlinski , U. Langenegger , B. Meier , T. Rohe , S. Streuli , P. -H. Chen , C. Dietz , F. Fiori , U. Grundler , W. -S. Hou , R. -S. Lu , M. Moya , J. -F. Tsai , Y. M. Tzeng , D. Cussans , J. Goldstein , M. Grimes , D. Newbold , P. Hobson , I. D. Reid , G. Auzinger , R. Bainbridge , P. Dauncey , G. Hall , T. James , A. -M. Magnan , M. Pesaresi , D. M. Raymond , K. Uchida , T. Durkin , K. Harder , C. Shepherd-Themistocleous , M. Chertok , J. Conway , R. Conway , C. Flores , R. Lander , D. Pellett , F. Ricci-Tam , M. Squires , J. Thomson , R. Yohay , K. Burt , J. Ellison , G. Hanson , M. Olmedo , W. Si , B. R. Yates , A. Dominguez , R. Bartek , B. Bentele , J. P. Cumalat , W. T. Ford , F. Jensen , A. Johnson , M. Krohn , S. Leontsinis , T. Mulholland , K. Stenson , S. R. Wagner , A. Apresyan , G. Bolla , K. Burkett , J. N. Butler , A. Canepa , H. W. K. Cheung , D. Christian , W. E. Cooper , G. Deptuch , G. Derylo , C. Gingu , S. Grünendahl , S. Hasegawa , J. Hoff , J. Howell , M. Hrycyk , S. Jindariani , M. Johnson , F. Kahlid , S. Kwan , C. M. Lei , R. Lipton , R. Lopes De Sá , T. Liu , S. Los , M. Matulik , P. Merkel , S. Nahn , A. Prosser , R. Rivera , B. Schneider , G. Sellberg , A. Shenai , K. Siehl , L. Spiegel , N. Tran , L. Uplegger , E. Voirin , D. R. Berry , X. Chen , L. Ennesser , A. Evdokimov , C. E. Gerber , S. Makauda , C. Mills , I. D. Sandoval Gonzalez , J. Alimena , L. J. Antonelli , B. Francis , A. Hart , C. S. Hill , N. Parashar , J. Stupak , D. Bortoletto , M. Bubna , N. Hinton , M. Jones , D. H. Miller , X. Shi , P. Baringer , A. Bean , S. Khalil , A. Kropivnitskaya , D. Majumder , E. Schmitz , G. Wilson , A. Ivanov , R. Mendis , T. Mitchell , N. Skhirtladze , R. Taylor , I. Anderson , D. Fehling , A. Gritsan , P. Maksimovic , C. Martin , K. Nash , M. Osherson , M. Swartz , M. Xiao , J. G. Acosta , L. M. Cremaldi , S. Oliveros , L. Perera , D. Summers , K. Bloom , D. R. Claes , C. Fangmeier , R. Gonzalez Suarez , J. Monroy , J. Siado , E. Bartz , Y. Gershtein , E. Halkiadakis , S. Kyriacou , A. Lath , K. Nash , M. Osherson , S. Schnetzer , R. Stone , M. Walker , S. Malik , S. Norberg , J. E. Ramirez Vargas , M. Alyari , J. Dolen , A. Godshalk , C. Harrington , I. Iashvili , A. Kharchilava , D. Nguyen , A. Parker , S. Rappoccio , B. Roozbahani , J. Alexander , J. Chaves , J. Chu , S. Dittmer , K. McDermott , N. Mirman , A. Rinkevicius , A. Ryd , E. Salvati , L. Skinnari , L. Soffi , Z. Tao , J. Thom , J. Tucker , M. Zientek , B. Akgün , K. M. Ecklund , M. Kilpatrick , T. Nussbaum , J. Zabel , P. D'Angelo , W. Johns , K. Rose

The complex system of the CMS all-silicon Tracker, with 15\,148 silicon strip and 1440 silicon pixel modules, requires sophisticated alignment procedures. In order to achieve an optimal track-parameter resolution, the position and…

Instrumentation and Detectors · Physics 2011-08-31 Claus Kleinwort , Frank Meier

The CMS inner pixel detector system is planned to be replaced during the first phase of the LHC luminosity upgrade. The plans foresee an ultra low mass system with four barrel layers and three disks on either end. With the expected increase…

Instrumentation and Detectors · Physics 2019-08-13 Carlotta Favaro

The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical…

Instrumentation and Detectors · Physics 2020-12-29 The Tracker Group of the CMS Collaboration

The LHC machine at CERN finished its first year of pp collisions at a center of mass energy of 7 TeV. While the commissioning to exploit its full potential is still ongoing, there are plans to upgrade its components to reach instantaneous…

Instrumentation and Detectors · Physics 2011-03-22 Hans-Christian Kästli

The present Compact Muon Solenoid silicon pixel tracking system has been designed for a peak luminosity of 1034cm-2s-1 and total dose corresponding to two years of the Large Hadron Collider (LHC) operation. With the steady increase of the…

Instrumentation and Detectors · Physics 2011-10-11 N. Parashar
‹ Prev 1 2 3 10 Next ›