Related papers: Dark Current Measurements on a Superconducting Cav…
The quality of Cadmium Zinc Telluride (CZT) detectors is steadily improving. For state of the art detectors, readout noise is thus becoming an increasingly important factor for the overall energy resolution. In this contribution, we present…
In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs…
We propose a new type of cryogenic current amplifiers, in which low-frequency power spectrum of current can be measured through a measurement of microwave response of a superconducting resonant circuit shunted by a series array of Josephson…
The conceptional design of the proposed linear electron-positron collider TESLA is based on 9-cell 1.3 GHz superconducting niobium cavities with an accelerating gradient of Eacc >= 25 MV/m at a quality factor Q0 > 5E+9. The design goal for…
An interlaboratory comparison of small-current generation and measurement capability is presented with the ultrastable low-noise current amplifier (ULCA) acting as travelling standard. Various measurements at direct currents between 0.16 nA…
Cryogenic thermoacoustic oscillations is an area of interest of several studies. For superconducting accelerators, it is an unwanted phenomena that we usually want to get rid off. The SPIRAL2 superconducting accelerator had distributed…
The Tera Electronvolt Superconducting Linear Accelerator TESLA is the only linear electron-positron collider project based on superconductor technology for particle acceleration. In the first stage with 500 GeV center-of-mass energy an…
A standard method for picoammeter calibrations is the capacitor charging technique, which allows generating traceable currents in the sub-nA range. However, its accuracy is limited by the ac-dc differences of the capacitances involved. The…
Thin pad detectors made from 75 $\mu$m thick epitaxial silicon on low resistivity substrate were irradiated with reactor neutrons to fluences from 2.5$\times 10^{16}$ n/cm$^2$ to 1$\times 10^{17}$ n/cm$^2$. Edge-TCT measurements showed that…
Developing a dark matter detector with wide mass tunability is an immensely desirable property, yet it is challenging due to maintaining strong sensitivity. Resonant cavities for dark matter detection have traditionally employed mechanical…
This paper presents a new shield configuration for cryogenic current comparators (CCCs), namely the folded coaxial geometry. An analytical model describing its shielding performance is first developed, and then validated by means of finite…
We developed a high-speed and low-noise time-domain current measurement scheme using a homemade GaAs high-electron-mobility-transistor-based cryogenic transimpedance amplifier (TIA). The scheme is versatile for broad cryogenic current…
The critical current density of a superconducting film can be easily determined by an inductive and contactless method. Driving a sinusoidal current in a single coil placed in front of a superconducting sample, a non zero third harmonic…
An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current…
Radiation hard helium gas ionization chambers capable of operating in vacuum at temperatures ranging from 5K to 350K have been designed, fabricated and tested and will be used inside the cryostats at Fermilab's Superconducting…
A new resistance bridge has been built at the Laboratoire national de m\'etrologie et d'essais (LNE) to improve the ohm realization in the $Syst\`eme International$ (SI) of units from the quantum Hall effect. We describe the instrument, the…
An ultrastable low-noise current amplifier (ULCA) has been transferred between two laboratories, NPL and PTB, four times, with three of the transfers yielding a relative change in the trans-resistance gain of less than $2 \times 10^{-7}$.…
The design of the proposed linear collider TESLA is based on 9-cell 1.3 GHz superconducting niobium cavities, operated in pulsed mode. Within the framework of an international collaboration the TESLA Test Facility (TTF) has been set up at…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
In dark matter searches using axion haloscopes, the search sensitivity depends on the quality factors ($Q_0$) of radiofrequency cavities immersed in multi-tesla magnetic fields. Increasing $Q_0$ would increase the scan rate through the…