English
Related papers

Related papers: Development of Fast and High Precision CMOS Pixel …

200 papers

We have developed a prototype system for the ILC vertex detector based on DEPFET pixels. The system operates a 128x64 matrix (with ~35x25 square micron large pixels) and uses two dedicated microchips, the SWITCHER II chip for matrix…

Fine pixel CCD (FPCCD) is one of the candidate sensor technologies for the vertex detector used for experiments at the International Linear Collider (ILC). A vertex detector system for the International Large Detector (ILD) using FPCCD…

Instrumentation and Detectors · Physics 2012-02-28 Yasuhiro Sugimoto , Hirokazu Ikeda , Daisuke Kamai , Eriko Kato , Akiya Miyamoto , Hisao Sato , Hitoshi Yamamoto

This paper presents the design and results of detailed tests of a CMOS active pixel chip for charged particle detection with in-pixel charge storage for correlated double sampling and readout in rolling shutter mode at frequencies up to 25…

Instrumentation and Detectors · Physics 2009-01-27 Marco Battaglia , Jean-Marie Bussat , Devis Contarato , Peter Denes , Piero Giubilato , Lindsay E. Glesener

Depleted Monolithic Active Pixel Sensors (DMAPS) constitute a promising low cost alternative for the outer layers of the ATLAS experiment Inner Tracker (ITk). Realizations in modern, high resistivity CMOS technologies enhance their…

In order to achieve the challenging requirements on the CLIC vertex detector, a range of technology options have been considered in recent years. One prominent idea is the use of active sensors implemented in a commercial high-voltage CMOS…

Detectors based on pixels with timing capabilities are gaining increasing importance in the last years. Next-to-come high-energy physics experiments at colliders requires the use of time information in tracking, due to the increasing levels…

Instrumentation and Detectors · Physics 2020-08-25 Adriano Lai , Gian Matteo Cossu

Fine pixel CCD (FPCCD) is an option for the sensor used for the ILC vertex detector to reduce the pixel occupancy due to the high background rate near the interaction point. In this paper, we report on the R&D status of FPCCD sensors and…

Instrumentation and Detectors · Physics 2010-07-16 Yasuhiro Sugimoto , Hirokazu Ikeda , Kennosuke Itagaki , Akiya Miyamoto , Yousuke Takubo , Hitoshi Yamamoto

Over the past few years we have developed, in collaboration with the SARNOFF Corporation, a design of a Monolithic CMOS Pixel Detector for ILC Vertex Detectors. The unique feature of this design is that each hit is accompanied by a time tag…

Instrumentation and Detectors · Physics 2011-09-14 C. Baltay , W. Emmet , D. Rabinowitz , J. Brau , N. Sinev , D. Strom

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R\&D program, aiming at using 3D pixel…

Instrumentation and Detectors · Physics 2025-10-16 The Tracker Group of the CMS Collaboration

Depleted monolithic active pixel sensors (DMAPS), which exploit high voltage and/or high resistivity add-ons of modern CMOS technologies to achieve substantial depletion in the sensing volume, have proven to have high radiation tolerance…

This is part of a document, which is devoted to the developments of pixel detectors in the context of the International Linear Collider. From the early developments of the MIMOSAs to the proposed DotPix I recall some of the major…

Instrumentation and Detectors · Physics 2020-03-24 Nicolas Fourches , University Paris-Saclay

The present Compact Muon Solenoid silicon pixel tracking system has been designed for a peak luminosity of 1034cm-2s-1 and total dose corresponding to two years of the Large Hadron Collider (LHC) operation. With the steady increase of the…

Instrumentation and Detectors · Physics 2011-10-11 N. Parashar

The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key…

Future space-based X-ray telescope missions are likely to have significantly increased demands on detector read out rates due to increased collection area, and there will be a desire to minimize radiation damage in the interests of…

Instrumentation and Methods for Astrophysics · Physics 2015-06-05 Abe D. Falcone , Zachary Prieskorn , Christopher Griffith , Stephen Bongiorno , David N. Burrows

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget…

Instrumentation and Detectors · Physics 2017-06-02 M. Dragicevic , M. Friedl , J. Hrubec , H. Steininger , A. Gädda , J. Härkönen , T. Lampén , P. Luukka , T. Peltola , E. Tuominen , E. Tuovinen , A. Winkler , P. Eerola , T. Tuuva , G. Baulieu , G. Boudoul , L. Caponetto , C. Combaret , D. Contardo , T. Dupasquier , G. Gallbit , N. Lumb , L. Mirabito , S. Perries , M. Vander Donckt , S. Viret , C. Bonnin , L. Charles , L. Gross , J. Hosselet , D. Tromson , L. Feld , W. Karpinski , K. Klein , M. Lipinski , G. Pierschel , M. Preuten , M. Rauch , M. Wlochal , M. Aldaya , C. Asawatangtrakuldee , K. Beernaert , D. Bertsche , C. Contreras-Campana , G. Eckerlin , D. Eckstein , T. Eichhorn , E. Gallo , J. Garay Garcia , K. Hansen , M. Haranko , A. Harb , J. Hauk , J. Keaveney , A. Kalogeropoulos , C. Kleinwort , W. Lohmann , R. Mankel , H. Maser , G. Mittag , C. Muhl , A. Mussgiller , D. Pitzl , O. Reichelt , M. Savitskyi , P. Schütze , V. Sola , S. Spannagel , R. Walsh , A. Zuber , H. Biskop , P. Buhmann , M. Centis-Vignali , E. Garutti , J. Haller , M. Hoffmann , R. Klanner , T. Lapsien , M. Matysek , A. Perieanu , Ch. Scharf , P. Schleper , A. Schmidt , J. Schwandt , J. Sonneveld , G. Steinbrück , B. Vormwald , J. Wellhausen , M. Abbas , C. Amstutz , T. Barvich , Ch. Barth , F. Boegelspacher , W. De Boer , E. Butz , M. Casele , F. Colombo , A. Dierlamm , B. Freund , F. Hartmann , S. Heindl , U. Husemann , A. Kornmeyer , S. Kudella , Th. Muller , H. J. Simonis , P. Steck , M. Weber , Th. Weiler , T. Kiss , F. Siklér , T. Tölyhi , V. Veszprémi , P. Cariola , D. Creanza , M. De Palma , G. De Robertis , L. Fiore , M. Franco , F. Loddo , G. Sala , L. Silvestris , G. Maggi , S. My , G. Selvaggi , S. Albergo , G. Cappello , S. Costa , A. Di Mattia , F. Giordano , R. Potenza , M. A. Saizu , A. Tricomi , C. Tuve , E. Focardi , M. E. Dinardo , S. Fiorendi , S. Gennai , S. Malvezzi , R. A. Manzoni , D. Menasce , L. Moroni , D. Pedrini , P. Azzi , N. Bacchetta , D. Bisello , M. Dall'Osso , N. Pozzobon , M. Tosi , L. Alunni Solestizi , M. Biasini , G. M. Bilei , C. Cecchi , B. Checcucci , D. Ciangottini , L. Fanò , C. Gentsos , M. Ionica , R. Leonardi , E. Manoni , G. Mantovani , S. Marconi , V. Mariani , M. Menichelli , A. Modak , A. Morozzi , F. Moscatelli , D. Passeri , P. Placidi , V. Postolache , A. Rossi , A. Saha , A. Santocchia , L. Storchi , D. Spiga , K. Androsov , P. Azzurri , G. Bagliesi , A. Basti , T. Boccali , L. Borrello , F. Bosi , R. Castaldi , M. Ceccanti , M. A. Ciocci , R. Dell'Orso , S. Donato , G. Fedi , A. Giassi , M. T. Grippo , F. Ligabue , G. Magazzu , P. Mammini , F. Mariani , E. Mazzoni , A. Messineo , A. Moggi , F. Morsani , F. Palla , F. Palmonari , A. Profeti , F. Raffaelli , A. Ragonesi , A. Rizzi , A. Soldani , P. Spagnolo , R. Tenchini , G. Tonelli , A. Venturi , P. G. Verdini , D. Abbaneo , I. Ahmed , E. Albert , G. Auzinger , G. Berruti , J. Bonnaud , J. Daguin , A. D'Auria , S. Detraz , O. Dondelewski , B. Engegaard , F. Faccio , N. Frank , K. Gill , A. Honma , A. Kornmayer , A. Labaza , F. Manolescu , I. McGill , S. Mersi , S. Michelis , A. Onnela , M. Ostrega , S. Pavis , A. Peisert , J. -F. Pernot , P. Petagna , H. Postema , K. Rapacz , C. Sigaud , P. Tropea , J. Troska , A. Tsirou , F. Vasey , B. Verlaat , P. Vichoudis , L. Zwalinski , F. Bachmair , R. Becker , D. di Calafiori , B. Casal , P. Berger , L. Djambazov , M. Donega , C. Grab , D. Hits , J. Hoss , G. Kasieczka , W. Lustermann , B. Mangano , M. Marionneau , P. Martinez Ruiz del Arbol , M. Masciovecchio , M. Meinhard , L. Perozzi , U. Roeser , A. Starodumov , V. Tavolaro , R. Wallny , D. Zhu , K. Bösiger , L. Caminada , F. Canelli , V. Chiochia , A. de Cosa , C. Galloni , T. Hreus , B. Kilminster , C. Lange , R. Maier , J. Ngadiuba , D. Pinna , P. Robmann , S. Taroni , Y. Yang , W. Bertl , K. Deiters , W. Erdmann , R. Horisberger , H. -C. Kaestli , D. Kotlinski , U. Langenegger , B. Meier , T. Rohe , S. Streuli , P. -H. Chen , C. Dietz , F. Fiori , U. Grundler , W. -S. Hou , R. -S. Lu , M. Moya , J. -F. Tsai , Y. M. Tzeng , D. Cussans , J. Goldstein , M. Grimes , D. Newbold , P. Hobson , I. D. Reid , G. Auzinger , R. Bainbridge , P. Dauncey , G. Hall , T. James , A. -M. Magnan , M. Pesaresi , D. M. Raymond , K. Uchida , T. Durkin , K. Harder , C. Shepherd-Themistocleous , M. Chertok , J. Conway , R. Conway , C. Flores , R. Lander , D. Pellett , F. Ricci-Tam , M. Squires , J. Thomson , R. Yohay , K. Burt , J. Ellison , G. Hanson , M. Olmedo , W. Si , B. R. Yates , A. Dominguez , R. Bartek , B. Bentele , J. P. Cumalat , W. T. Ford , F. Jensen , A. Johnson , M. Krohn , S. Leontsinis , T. Mulholland , K. Stenson , S. R. Wagner , A. Apresyan , G. Bolla , K. Burkett , J. N. Butler , A. Canepa , H. W. K. Cheung , D. Christian , W. E. Cooper , G. Deptuch , G. Derylo , C. Gingu , S. Grünendahl , S. Hasegawa , J. Hoff , J. Howell , M. Hrycyk , S. Jindariani , M. Johnson , F. Kahlid , S. Kwan , C. M. Lei , R. Lipton , R. Lopes De Sá , T. Liu , S. Los , M. Matulik , P. Merkel , S. Nahn , A. Prosser , R. Rivera , B. Schneider , G. Sellberg , A. Shenai , K. Siehl , L. Spiegel , N. Tran , L. Uplegger , E. Voirin , D. R. Berry , X. Chen , L. Ennesser , A. Evdokimov , C. E. Gerber , S. Makauda , C. Mills , I. D. Sandoval Gonzalez , J. Alimena , L. J. Antonelli , B. Francis , A. Hart , C. S. Hill , N. Parashar , J. Stupak , D. Bortoletto , M. Bubna , N. Hinton , M. Jones , D. H. Miller , X. Shi , P. Baringer , A. Bean , S. Khalil , A. Kropivnitskaya , D. Majumder , E. Schmitz , G. Wilson , A. Ivanov , R. Mendis , T. Mitchell , N. Skhirtladze , R. Taylor , I. Anderson , D. Fehling , A. Gritsan , P. Maksimovic , C. Martin , K. Nash , M. Osherson , M. Swartz , M. Xiao , J. G. Acosta , L. M. Cremaldi , S. Oliveros , L. Perera , D. Summers , K. Bloom , D. R. Claes , C. Fangmeier , R. Gonzalez Suarez , J. Monroy , J. Siado , E. Bartz , Y. Gershtein , E. Halkiadakis , S. Kyriacou , A. Lath , K. Nash , M. Osherson , S. Schnetzer , R. Stone , M. Walker , S. Malik , S. Norberg , J. E. Ramirez Vargas , M. Alyari , J. Dolen , A. Godshalk , C. Harrington , I. Iashvili , A. Kharchilava , D. Nguyen , A. Parker , S. Rappoccio , B. Roozbahani , J. Alexander , J. Chaves , J. Chu , S. Dittmer , K. McDermott , N. Mirman , A. Rinkevicius , A. Ryd , E. Salvati , L. Skinnari , L. Soffi , Z. Tao , J. Thom , J. Tucker , M. Zientek , B. Akgün , K. M. Ecklund , M. Kilpatrick , T. Nussbaum , J. Zabel , P. D'Angelo , W. Johns , K. Rose

The phase 1 upgrade of the CMS pixel detector has been designed to maintain the tracking performance at instantaneous luminosities of $2 \times 10^{34} \mathrm{~cm}^{-2} \mathrm{~s}^{-1}$. Both barrel and endcap disk systems now feature one…

Instrumentation and Detectors · Physics 2018-07-25 Jory Sonneveld

In recent years, the performance of Scientifc Complementary Metal Oxide Semiconductor (sCMOS) sensors has been improved signifcantly. Compared with CCD sensors, sCMOS sensors have various advantages, making them potentially better devices…

Instrumentation and Methods for Astrophysics · Physics 2022-10-05 Qinyu Wu , Zhenqing Jia , Wenxin Wang , Zhixing Ling , Chen Zhang , Shuangnan Zhang , Weimin Yuan

The next-generation ALICE 3 experiment at the High-Luminosity LHC (HL-LHC) requires detector technologies that combine fine spatial resolution, fast timing, and an extremely low material budget. This paper presents the design,…

Instrumentation and Detectors · Physics 2026-01-07 Umberto Follo

A new pixel detector for the CMS experiment is being built, owing to the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking while featuring a significantly…

Instrumentation and Detectors · Physics 2016-12-23 Simon Spannagel

The physics aims at the proposed future high-energy linear $e^+e^-$ collider CLIC pose challenging demands on the performance of the detector system. In particular, the vertex and tracking detectors have to combine a spatial resolution of a…

Instrumentation and Detectors · Physics 2020-10-22 Katharina Dort