English
Related papers

Related papers: Multi-channel gas electron multiplier with metalli…

200 papers

Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high radiation environment expected during the future…

Instrumentation and Detectors · Physics 2018-12-12 Aashaq Shah , CMS-Muon Collaboration

The Negative Ion Drift (NID) gas SF$_6$ has favourable properties for track reconstruction in directional Dark Matter (DM) searches utilising low pressure gaseous Time Projection Chambers (TPCs). However, the electronegative nature of the…

Instrumentation and Detectors · Physics 2023-11-20 A. G. McLean , N. J. C. Spooner , T. Crane , C. Eldridge , A. C. Ezeribe , R. R. Marcelo Gregorio , A. Scarff

We report a new technique for fabricating metallic electrodes on insulating substrates with separations on the 1 nm scale. The fabrication technique, which combines lithographic and electrochemical methods, provides atomic resolution…

Materials Science · Physics 2009-10-31 A. F. Morpurgo , D. B. Robinson , C. M. Marcus

We have fabricated pairs of platinum electrodes with separation between 20 and 3.5 nm. Our technique combines electron beam lithography and chemical electrodeposition. We show that the measurement of the conductance between the two…

Materials Science · Physics 2009-11-10 Y. -V. Kervennic , H. S. J. Van der Zant , A. F. Morpurgo , L. Gurevich , L. P. Kouwenhoven

A quadruple GEM detector has been assembled in a standalone configuration and operated using Ar and CO$_2$ gas mixtures in proportions of 70:30 and 90:10. Detailed performance study of the detector has been made by using $^{106}$Ru-Rh…

Instrumentation and Detectors · Physics 2018-10-09 Rajendra Nath Patra , Rama Narayan Singaraju , Saikat Biswas , Yogendra P. Viyogi , Tapan K. Nayak

A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under…

Instrumentation and Detectors · Physics 2016-12-26 Yu-Ning Zhang , Qian Liu , Hong-Bang Liu , Yi-Gang Xie , Xiao-Rui Lyu , Shi Chen , Wen-Qian Huang , Dao-Jin Hong , Yang-Heng Zheng

The Gas Electron Multiplier (GEM) foil is an amplification stage that has been introduced to overcome the problem of discharges observed in gaseous detectors. There are two major production techniques of GEM foils: double-mask and…

Instrumentation and Detectors · Physics 2021-12-02 Othmane Bouhali , Kerstin Hoepfner , Francesco Ivone , Teruki Kamon , Henning Keller , Shivali Malhotra , Badriya Al Rashdi

We present a numerical study of a multichannel electronic Mach-Zehnder interferometer, based on magnetically-driven non-interacting edge states. The electron path is defined by a full-scale potential landscape on the two-dimensional…

Mesoscale and Nanoscale Physics · Physics 2018-05-23 Laura Bellentani , Andrea Beggi , Paolo Bordone , Andrea Bertoni

We report promising initial results obtained with new resistive-electrode GEM (RETGEM) detectors manufactured, for the first time, using screen printing technology. These new detectors allow one to reach gas gains nearly as high as with…

Instrumentation and Detectors · Physics 2009-12-10 B. Clark , A. G. Agocs , R. Oliveira , V. Peskov , Pietropaolo , Picchi

The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter in charge of the electron background rejection downstream of the cooling channel at the international Muon Ionization Cooling Experiment. It consists of 2832 plastic…

Instrumentation and Detectors · Physics 2017-10-20 Francois Drielsma

We succeeded in modifying and controlling the electrical resistance of a standard High Pressure Laminate (HPL) panel through the use of a Gas Electron Multiplier (GEM) foil that has been embedded into the bulk of the HPL plate itself.…

Instrumentation and Detectors · Physics 2018-03-22 P. Vitulo

From its invention in 1997, the Gas Electron Multiplier has been applied in nuclear and high energy physics experiments. Over time however, other applications have also exploited the favorable properties of GEMs. The use of GEMs in these…

Instrumentation and Detectors · Physics 2013-04-12 Serge Duarte Pinto

We study the performance of the triple-GEM (Gas Electron Multiplier) detector in pure noble gases Ne, Ar and Xe, at different pressures varying from 1 to 10 atm. In Ar and Xe, the maximum attainable gain of the detector abruptly drops down…

Instrumentation and Detectors · Physics 2009-11-07 A. Bondar , A. Buzulutskov , L. Shekhtman

A single-mask Gas Electron Multiplier (GEM) technique overcomes the cumbersome practice of alignment of two masks and allows the production of foils with very large area as needed for the CMS muon forward region upgrade. However, the holes…

Instrumentation and Detectors · Physics 2018-11-14 Aashaq Shah , Archana Sharma , Ashok Kumar , Jeremie Merlin , Md. Naimuddin

At NISER-IoP detector laboratory an initiative is taken to build and test Gas Electron Multiplier (GEM) detectors for ALICE experiment. The optimisation of the gas flow rate and the long-term stability test of the GEM detector are…

We perform self-consistent Schr\"odinger-Poisson calculations with exchange and correlation corrections to determine the electron/hole gas in a radial hetero-junction formed in a modulation doped GaAs/AlGaAs core-multi-shell nanowire (CSNW)…

Mesoscale and Nanoscale Physics · Physics 2016-04-29 Andrea Bertoni , Miquel Royo , Farah Mahawish , Guido Goldoni

We present the first micropattern gaseous detector that employs a small 3D-printed Thick-GEM as its sole gain element. The detector can achieve sufficient gas gain for regular operation without the need for pre-amplification by additional…

Instrumentation and Detectors · Physics 2025-11-11 J. Collins , M. Hohlmann

Dual-phase liquid xenon time projection chambers are the core detector elements of many experiments that conduct searches for Dark Matter and rare events, as well as in neutrino and high-energy physics. As part of this detector technology,…

In electronic devices where a two-dimensional electron gas (2DEG) comprises one or both sides of a plane capacitor, the resulting capacitance $C$ can be larger than the "geometric capacitance" $C_g$ determined by the physical separation $d$…

Mesoscale and Nanoscale Physics · Physics 2012-07-06 Brian Skinner , B. I. Shklovskii