Related papers: Multi-channel gas electron multiplier with metalli…
Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high radiation environment expected during the future…
At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-\eta region. An international collaboration is investigating the possibility of covering the 1.6 < |\eta| < 2.4 region of…
The Negative Ion Drift (NID) gas SF$_6$ has favourable properties for track reconstruction in directional Dark Matter (DM) searches utilising low pressure gaseous Time Projection Chambers (TPCs). However, the electronegative nature of the…
We report a new technique for fabricating metallic electrodes on insulating substrates with separations on the 1 nm scale. The fabrication technique, which combines lithographic and electrochemical methods, provides atomic resolution…
We have fabricated pairs of platinum electrodes with separation between 20 and 3.5 nm. Our technique combines electron beam lithography and chemical electrodeposition. We show that the measurement of the conductance between the two…
A quadruple GEM detector has been assembled in a standalone configuration and operated using Ar and CO$_2$ gas mixtures in proportions of 70:30 and 90:10. Detailed performance study of the detector has been made by using $^{106}$Ru-Rh…
A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under…
The Gas Electron Multiplier (GEM) foil is an amplification stage that has been introduced to overcome the problem of discharges observed in gaseous detectors. There are two major production techniques of GEM foils: double-mask and…
We present a numerical study of a multichannel electronic Mach-Zehnder interferometer, based on magnetically-driven non-interacting edge states. The electron path is defined by a full-scale potential landscape on the two-dimensional…
We report promising initial results obtained with new resistive-electrode GEM (RETGEM) detectors manufactured, for the first time, using screen printing technology. These new detectors allow one to reach gas gains nearly as high as with…
The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter in charge of the electron background rejection downstream of the cooling channel at the international Muon Ionization Cooling Experiment. It consists of 2832 plastic…
We succeeded in modifying and controlling the electrical resistance of a standard High Pressure Laminate (HPL) panel through the use of a Gas Electron Multiplier (GEM) foil that has been embedded into the bulk of the HPL plate itself.…
From its invention in 1997, the Gas Electron Multiplier has been applied in nuclear and high energy physics experiments. Over time however, other applications have also exploited the favorable properties of GEMs. The use of GEMs in these…
We study the performance of the triple-GEM (Gas Electron Multiplier) detector in pure noble gases Ne, Ar and Xe, at different pressures varying from 1 to 10 atm. In Ar and Xe, the maximum attainable gain of the detector abruptly drops down…
A single-mask Gas Electron Multiplier (GEM) technique overcomes the cumbersome practice of alignment of two masks and allows the production of foils with very large area as needed for the CMS muon forward region upgrade. However, the holes…
At NISER-IoP detector laboratory an initiative is taken to build and test Gas Electron Multiplier (GEM) detectors for ALICE experiment. The optimisation of the gas flow rate and the long-term stability test of the GEM detector are…
We perform self-consistent Schr\"odinger-Poisson calculations with exchange and correlation corrections to determine the electron/hole gas in a radial hetero-junction formed in a modulation doped GaAs/AlGaAs core-multi-shell nanowire (CSNW)…
We present the first micropattern gaseous detector that employs a small 3D-printed Thick-GEM as its sole gain element. The detector can achieve sufficient gas gain for regular operation without the need for pre-amplification by additional…
Dual-phase liquid xenon time projection chambers are the core detector elements of many experiments that conduct searches for Dark Matter and rare events, as well as in neutrino and high-energy physics. As part of this detector technology,…
In electronic devices where a two-dimensional electron gas (2DEG) comprises one or both sides of a plane capacitor, the resulting capacitance $C$ can be larger than the "geometric capacitance" $C_g$ determined by the physical separation $d$…