Related papers: Tests of a Digital Hadron Calorimeter
A silicon-based fine granularity calorimeter is a potential technology for the future International Linear Collider ILC, the future circular collider CEPC, and is also the chosen technology for the upgraded CMS experiment of the Large…
The performance of the CMS electromagnetic calorimeter upgraded readout electronics, developed for the High-Luminosity phase of the LHC, is discussed. Data collected in two beam test campaigns conducted in 2018 and 2021 at the H4 and H2…
The CALICE collaboration has constructed highly granular hadronic and electromagnetic calorimeter prototypes to evaluate technologies for the use in detector systems at a future Linear Collider. The hadron calorimeter uses 7608 small…
The next generation of collider detectors will make full use of Particle Flow Algorithms, requiring high-precision tracking and full imaging calorimeters. The latter, thanks to granularity improvements by two to three orders of magnitude…
A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here…
Beam studies of thin single- and double-stage THGEM-based detectors are presented. Several 10 x 10 cm^2 configurations with a total thickness of 5-6 mm (excluding readout electronics), with 1 x 1 cm^2 pads inductively coupled through a…
Neutrinos, elusive and abundant, interact weakly with matter, making detection challenging. This thesis explores neutrino physics, focusing on mass hierarchy and oscillations, with emphasis on India's upcoming INO facility. The Iron…
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) is the first technological prototype in a family of high-granularity calorimeters developed by the CALICE Collaboration to equip the experiments of future lepton colliders. The SDHCAL is…
In the Energy Frontier we suggest developing high rate (100 MHz) finely segmented forward calorimetry preradiators with time resolution <50 ps which will survive the first 1-2 Lint of incident high radiation doses, protecting forward…
We present results on the performance of the first prototype of the CASTOR quartz-tungsten sampling calorimeter, to be installed in the very forward region of the CMS experiment at the LHC. This study includes GEANT Monte Carlo simulations…
In 2002 the first combined beam test of the hadronic and electromagnetic liquid-argon endcap calorimeters of the ATLAS experiment took place at the SPS test beam at CERN. A total of 15 million events from electrons, muons and pions in the…
The readout electronics upgrade for the ATLAS Liquid Argon Calorimeters at the CERN Large Hadron Collider requires a radiation-hard ADC. The design of a radiation-hard dual-channel 12-bit 40 MS/s pipeline ADC for this use is presented. The…
In this paper we simulate the emission by charged particles in complex structures with help of Geant4. We take into account Cherenkov radiation, transition radiation, bremsstrahlung, pair production and other accompanying processes. As an…
The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of…
The studies presented in this paper provide a first experimental test of the Particle Flow Algorithm (PFA) concept using data recorded in high granularity calorimeters. Pairs of overlaid pion showers from CALICE 2007 test beam data are…
The CDF experiment is successfully collecting data from ppbar collisions at the Tevatron in Run II. As the data samples are getting larger, systematic uncertainties due to the measurement of the jet energy scale assessed using the…
Jet substructure variables for hadronic jets with transverse momenta in the range from 2.5 TeV to 20 TeV were studied using several designs for the spatial size of calorimeter cells. The studies used the full Geant4 simulation of…
This work has been carried out to simulate a Resistive Plate Chamber and corroborate it with experimental measurements in order to develop a numerical tool for studying the performance of the device for any gas mixture. This will allow us…
The SDHCAL technological prototype is a $1 \times 1 \times 1.3$~m$^3$ high-granularity Semi-Digital Hadronic CALorimeter using Glass Resistive Plate Chambers as sensitive medium. It is one of the two HCAL options considered by the ILD…
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with…