English
Related papers

Related papers: The GlueX Central Drift Chamber: Design and Perfor…

200 papers

The GlueX Central Drift Chamber (CDC) in Hall D at Jefferson Lab, used for detecting and tracking charged particles, is calibrated and controlled during data taking using a Gaussian process. The system dynamically adjusts the high voltage…

Instrumentation and Detectors · Physics 2024-07-04 Thomas Britton , Michael Goodrich , Naomi Jarvis , Torri Jeske , Nikhil Kalra , David Lawrence , Diana McSpadden , Kishan Rajput

The Central Drift Chamber is a straw-tube wire chamber of cylindrical structure located surrounding the target inside the bore of the GlueX spectrometer solenoid. Its purpose is to detect and track charged particles with momenta as low as…

The performance of a small prototype of a cylindrical drift chamber (CDC) used in the COMET Phase-I experiment was studied by using an electron beam. The prototype chamber was constructed with alternating all-stereo wire configuration and…

Instrumentation and Detectors · Physics 2021-09-07 C. Wu , T. S. Wong , Y. Kuno , M. Moritsu , Y. Nakazawa , A. Sato , H. Sakamoto , N. H. Tran , M. L. Wong , H. Yoshida , T. Yamane , J. Zhang

A possible implementation of the Micro Drift Chamber (MDC) technique as a high resolution vertex detector in the upstream part of the DIRAC spectrometer was investigated in this paper. Simulations of different MDC layout were performed with…

Instrumentation and Detectors · Physics 2008-05-16 A. Dudarev , V. Kruglov , L. Kruglova , M. Nikitin

The GlueX experiment was designed to search for and study the pattern of gluonic excitations in the meson spectrum produced through photoproduction reactions at a new tagged photon beam facility in Hall D at Jefferson Laboratory. The…

The GlueX experiment at Jefferson Laboratory aims to perform quantitative tests of non-perturbative QCD by studying the spectrum of light-quark mesons and baryons. A Detector of Internally Reflected Cherenkov light (DIRC) was installed to…

The MEG-II experiment searches for the lepton flavor violating decay: mu in electron and gamma. The reconstruction of the positron trajectory uses a cylindrical drift chamber operated with a mixture of He and iC4H10 gas. It is important to…

Instrumentation and Detectors · Physics 2020-06-11 F. Cuna , G. Chiarello , A. Corvaglia , N. De Filippis , F. Grancagnolo , M. Manta , I. Margjeka , A. Miccoli , M. Panareo , G. F. Tassielli

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a…

Instrumentation and Detectors · Physics 2022-03-17 S. Adhikari , C. S. Akondi , H. Al Ghoul , A. Ali , M. Amaryan , E. G. Anassontzis , A. Austregesilo , F. Barbosa , J. Barlow , A. Barnes , E. Barriga , R. Barsotti , T. D. Beattie , J. Benesch , V. V. Berdnikov , G. Biallas , T. Black , W. Boeglin , P. Brindza , W. J. Briscoe , T. Britton , J. Brock , W. K. Brooks , B. E. Cannon , C. Carlin , D. S. Carman , T. Carstens , N. Cao , O. Chernyshov , E. Chudakov , S. Cole , O. Cortes , W. D. Crahen , V. Crede , M. M. Dalton , T. Daniels , A. Deur , C. Dickover , S. Dobbs , A. Dolgolenko , R. Dotel , M. Dugger , R. Dzhygadlo , A. Dzierba , H. Egiyan , T. Erbora , A. Ernst , P. Eugenio , C. Fanelli , S. Fegan , A. M. Foda , J. Foote , J. Frye , S. Furletov , L. Gan , A. Gasparian , A. Gerasimov , N. Gevorgyan , C. Gleason , K. Goetzen , A. Goncalves V. S. Goryachev , L. Guo , H. Hakobyan , A. Hamdi , J. Hardin , C. L. Henschel , G. M. Huber , C. Hutton , A. Hurley , P. Ioannou , D. G. Ireland , M. M. Ito , N. S. Jarvis , R. T. Jones , V. Kakoyan , S. Katsaganis , G. Kalicy , M. Kamel , C. D. Keith , F. J. Klein , R. Kliemt , D. Kolybaba , C. Kourkoumelis , S. T. Krueger , S. Kuleshov , I. Larin , D. Lawrence , J. P. Leckey , D. I. Lersch , B. D. Leverington , W. I. Levine , W. Li , B. Liu , K. Livingston , G. J. Lolos , V. Lyubovitskij , D. Mack , H. Marukyan , P. T. Mattione , V. Matveev , M. McCaughan , M. McCracken , W. McGinley , J. McIntyre , D. Meekins , R. Mendez , C. A. Meyer , R. Miskimen , R. E. Mitchell , F. Mokaya , K. Moriya , F. Nerling , L. Ng , H. Ni , A. I. Ostrovidov , Z. Papandreou , M. Patsyuk , C. Paudel , P. Pauli , R. Pedroni , L. Pentchev , K. J. Peters , W. Phelps , J. Pierce , E. Pooser , V. Popov , B. Pratt , Y. Qiang , N. Qin , V. Razmyslovich , J. Reinhold , B. G. Ritchie , J. Ritman , L. Robison , D. Romanov , C. Romero , C. Salgado , N. Sandoval , T. Satogata , A. M. Schertz , S. Schadmand , A. Schick , R. A. Schumacher , C. Schwarz , J. Schwiening , A. Yu. Semenov , I. A. Semenova , K. K. Seth , X. Shen , M. R. Shepherd , E. S. Smith , D. I. Sober , A. Somov , S. Somov , O. Soto , N. Sparks , M. J. Staib , C. Stanislav , J. R. Stevens , J. Stewart , I. I. Strakovsky , B. C. L. Summner , K. Suresh , V. V. Tarasov , S. Taylor , L. A. Teigrob , A. Teymurazyan , A. Thiel , I. Tolstukhin , A. Tomaradze , A. Toro , A. Tsaris , Y. Van Haarlem , G. Vasileiadis , I. Vega , G. Visser , G. Voulgaris , N. K. Walford , D. Werthmüller , T. Whitlatch , N. Wickramaarachchi , M. Williams , E. Wolin , T. Xiao , Y. Yang , J. Zarling , Z. Zhang , Q. Zhou , X. Zhou , B. Zihlmann

The performance of the GlueX Forward Calorimeter was studied using a small version of the detector and a variable energy electron beam derived from the Hall B tagger at Jefferson Lab. For electron energies from 110 MeV to 260 MeV, which are…

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…

This article presents the MEG II Cylindrical Drift CHamber (CDCH), a key detector for the phase 2 of MEG, which aims at reaching a sensitivity level of the order of $6 \times 10^{-14}$ for the charged Lepton Flavour Violating $\mu^+…

The MEG experiment at the Paul Scherrer Institut searches for the charged-Lepton-Flavor-Violating mu+ -> e+ gamma decay. MEG has already set the world best upper limit on the branching ratio: BR<4.2x10^-13 @ 90% C.l. An upgrade (MEG II) of…

Final report for the AI Assisted Experiment Control and Calibration project. This project integrated AI/ML into the controls and calibration of a production detector system in the GlueX spectrometer, a large scale Nuclear Physics detector…

Instrumentation and Detectors · Physics 2024-02-22 Thomas Britton , Michael Goodrich , Naomi Jarvis , Torri Jeske , Nikhil Kalra , David Lawrence , Diana McSpadden

The IDEA detector concept for a future e$^{+}$e$^{-}$ collider adopts an ultra-low mass drift chamber as a central tracking system. The He-based ultra-low mass drift chamber is designed to provide efficient tracking, a high-precision…

The GlueX experiment takes place in experimental Hall D at Jefferson Lab (JLab). With a linearly polarized photon beam of up to 12 GeV energy, GlueX is a dedicated experiment to search for hybrid mesons via photoproduction reactions. The…

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…

Dedicated detector simulations are very important for the success of high energy physics experiments. They not only bring benefits to the optimization of the detectors, but can also improve the precision of the physics results. To design a…

Instrumentation and Detectors · Physics 2018-09-26 Fuyue Wang , Dong Han , Yi Wang , Yancheng Yu , Qiunan Zhang , Baohong Guo , Yuanjing Li

In this paper, we introduce a general scientific CCD simulation and test system which can meet the test requirements of different types of CCD chips from E2V company, such as measuring different signals output from modules of a CCD…

Instrumentation and Detectors · Physics 2019-03-06 Yi Zhang , Hong-fei Zhang , Jian-min Wang , Yi Feng , Cheng Chen , Zi-ang Wang , Qi-jie Tang , Guang-yu Zhang , Jian Wang

The GlueX experiment is located in experimental Hall D at Jefferson Lab (JLab) and provides a unique capability to search for hybrid mesons in high-energy photoproduction, utilizing a ~9 GeV linearly polarized photon beam. The initial,…

The design, simulation, fabrication, calibration, and performance of the GlueX Start Counter detector is described. The Start Counter was designed to operate at integrated rates of up to 9 MHz with a timing resolution in the range of 500 to…

‹ Prev 1 2 3 10 Next ›