Related papers: Imaging with high Dynamic using an Ionization Cham…
An X-ray detector will be presented that is the combination of a segmented ionization chamber featuring one-dimensional spatial resolution integrated with an intelligent ADC front-end, multi DSP processing and embedded PC platform. This…
A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536…
We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge…
The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. Optimized for use with low-energy radioactive beams (< 5 MeV/A) the…
A single channel, high precision ionization chamber has been built for monitoring the relative intensity of X-rays in the energy range above 5 keV. It can be used in experiments, such as EXAFS, where simultaneous high precision monitoring…
An axial gas ionization chamber has been fabricated for use as a $\Delta E$ detector in heavy ion induced nuclear reactions. Different operating parameters such as gas type, pressure, anode voltage and anode structures have been optimized.…
Radon is a naturally occurring radioactive gas that contributes significantly to human radiation exposure and must be controlled to avoid concentrations harmful to health. The paper presents an impulse-proportional ionization chamber that…
We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a…
We demonstrate a compact ion beam device capable of accelerating H$^+$ and D$^+$ ions up to 75keV energy, on to a solid target, with sufficient beam current to study fusion reactions. The ion beam system uses a microwave driven plasma…
Ionization chambers are essential for activity determinations in radionuclide metrology. We have developed a high-precision integrating-differentiating (int-diff) system for measuring small currents. It is anticipated to enhance the…
We describe a high resolution imaging detector based on a single 80 mm micro-channel-plate (MCP) and a phosphor screen mounted on a UHV flange of only 100 mm inner diameter. It relies on standard components and we describe its performance…
We present the design of a Velocity Map Imaging apparatus tailored to the demands of high-resolution crossed molecular beam experiments employing Stark or Zeeman decelerators. The key requirements for these experiments consist of the…
We present the design and characterization of a cryogenic vacuum chamber incorporating mechanical isolation from vibrations, a high numerical-aperture in-vacuum imaging objective, in-vacuum magnetic shielding, and an antenna for global…
We introduce a novel particle detection concept for large-volume, fine granularity particle detection: The Ion Fluorescence Chamber (IFC). In electronegative gases such as SF$_6$ and SeF$_6$, ionizing particles create ensembles of positive…
A fast-reading current integrator is developed for high time-resolution and low-noise ion beam diagnostics under both continuous-wave and pulsed operating conditions. The system combines a low-leakage transimpedance front-end with a hybrid…
We describe the development, operation, and application of the 4D Camera -- a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at approximately 480…
We present a concept for an Advanced Compton Telescope (ACT) based on the use of pixelized gas micro-well detectors to form a three-dimensional electron track imager. A micro-well detector consists of an array of individual micro-patterned…
A 64-channel mixed-mode ASIC, suitable for particle detectors of large dynamic range and high capacitance up to hundreds of pF, is presented here. Each channel features an analogue front-end for signal amplification and filtering, and a…
The combination of graphene with semiconductor materials in heterostructure photodetectors, has enabled amplified detection of femtowatt light signals using micron-scale electronic devices. Presently, the speed of such detectors is limited…
Air-ionization chambers have been used in radiotherapy and particle therapy for decades. However, fundamental parameters in action in the detector responses are sparsely studied. In this work we aimed to measure the electronic attachment,…