English
Related papers

Related papers: A high dynamic Micro Strips Ionization Chamber fea…

200 papers

In this work a combination of an ionization chamber with one-dimensional spatial resolution and a MicroCAT structure will be presented. The combination between gas gain operations and integrating front-end electronics yields a dynamic range…

Instrumentation and Detectors · Physics 2015-05-18 Ralf-Hendrik Menk , Heinz Amenitsch , Fulvia Arfelli , Sigrid Bernstorff , Hans Juergen Besch , Francesco Voltolina

We evaluate the performances of a 100 um-thick silicon strip detector (SSD) with a 300 MeV proton beam and a 90Sr beta-ray source. Signals from the SSD have been read out using a VLSI chip. Common-mode noise, signal separation efficiency…

Instrumentation and Detectors · Physics 2007-05-23 T. Hotta , M. Fujiwara , T. Kinashi , Y. Kuno , M. Kuss , T. Matsumura , T. Nakano , S. Sekikawa , H. Tajima

We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge…

Instrumentation and Detectors · Physics 2009-11-10 F. Gomez , A. Iglesias , R. Lobato , J. Mosquera , J. Pardo , J. Pena , A. Pazos , M. Pombar , A. Rodriguez

A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536…

High Energy Physics - Experiment · Physics 2015-06-25 T. Nagayoshi , H. Kubo , K. Miuchi , A. Ochi , R. Orito , A. Takada , T. Tanimori , M. Ueno

We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in…

A silicon microstrip detector (SSD) has been developed to have state of the art spatial resolution and a large sensitive area under stringent power constraints. The design incorporates three floating strips with their bias resistors…

We report on broad instantaneous bandwidth microwave spectrum analysis with hot $^{87}\mathrm{Rb}$ atoms in a microfabricated vapor cell in a large magnetic field gradient. The sensor is a MEMS atomic vapor cell filled with isotopically…

Atomic Physics · Physics 2024-08-13 Yongqi Shi , Thomas Ruster , Melvyn Ho , Sylvain Karlen , Jacques Haesler , Philipp Treutlein

We developed CdTe double-sided strip detectors (DSDs or cross strip detectors) and evaluated their spectral and imaging performance for hard X-rays and gamma-rays. Though the double-sided strip configuration is suitable for imagers with a…

A large area Resistive Plate Chamber (RPC) with a total active surface of 160x10 cm2 was built and tested. The surface was segmented in two 5 cm wide strips readout on both ends with custom, very high frequency, front end electronics. A…

Instrumentation and Detectors · Physics 2009-11-07 A. Blanco , R. Ferreira-Marques , Ch. Finck , P. Fonte , A. Gobbi , A. Policarpo , M. Rozas

Digital signal processing (DSP) is supporting novel in-field applications of optical interferometry, such as in laser ranging and distributed acoustic sensing. While the highest performances are achieved with field-programmable gated arrays…

Signal Processing · Electrical Eng. & Systems 2023-08-08 Simone Donadello , Elio K. Bertacco , Davide Calonico , Cecilia Clivati

We describe a high resolution imaging detector based on a single 80 mm micro-channel-plate (MCP) and a phosphor screen mounted on a UHV flange of only 100 mm inner diameter. It relies on standard components and we describe its performance…

Instrumentation and Detectors · Physics 2018-05-30 Sylvain Lupone , Pierre Soulisse , Philippe Roncin

A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in…

Instrumentation and Detectors · Physics 2017-09-20 B. B. Wiggins , Varinderjit Singh , J. Vadas , J. Huston , T. K. Steinbach , S. Hudan , R. T. deSouza

A prototype of Multi-strip Multi-gap Resistive Plate chamber (MMRPC) with active area 40 cm $\times$ 20 cm has been developed at SINP, Kolkata. Detailed response of the developed detector was studied with the pulsed electron beam from ELBE…

A front-end readout electronics system has been developed for silicon strip detectors. The system uses an application specific integrated circuit (ASIC) ATHED to realize multi-channel E&T measurement. The slow control of ASIC chips is…

Instrumentation and Detectors · Physics 2011-06-13 Yi Qian , Hong Su , Jie Kong , Cheng-Fu Dong , Xiao-Li Ma , Xiao-Gang Li

Modern X-ray detector systems urgently require compact, efficient, and fast data compression schemes to handle the transmission of big data from pixel arrays, enabling frame rates in the MHz regime. In this work, a data compression ASIC…

The Phase-II Upgrade of the ATLAS Muon Detector requires new electronics for the readout of the MDT drift tubes. The first processing stage, the Amplifier-Shaper-Discriminator (ASD), determines the performance of the readout for crucial…

We report on the design, production, and testing of advanced double-sided silicon strip detectors under development at the Max-Planck-Institute as part of the Medium Energy Gamma-ray Astronomy (MEGA) project. The detectors are designed to…

Astrophysics · Physics 2009-11-07 P. F. Bloser , F. Schopper , R. Andritschke , G. Kanbach , A. Zoglauer , P. Lechner

In the context of the Silicon tracking for a Linear Collider (SiLC) R&D collaboration, a highly compact mixed-signal chip has been designed in 130nm CMOS technology intended to read Silicon strip detectors for the experiments at the future…

Instrumentation and Detectors · Physics 2009-03-27 Aurore Savoy-Navarro , Jean F. Genat , Th. Hung Pham , Rachid. Sefri , Albert Comerma , Angel Dieguez

A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{\mu m}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use…

Instrumentation and Detectors · Physics 2024-01-25 Kei Ieki , Weiyuan Li , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Atsushi Oya , Masato Takahashi , Kensuke Yamamoto

A liquid isooctane (C$_{8}$H$_{18}$) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm $\times$ 1.7 mm and a gap…

Medical Physics · Physics 2009-11-10 J. Pardo , L. Franco , F. Gomez , A. Iglesias , A. Pazos , J. Pena , R. Lobato , J. Mosquera , M. Pombar , J. Sendon
‹ Prev 1 2 3 10 Next ›