English
Related papers

Related papers: PARISROC, a photomultiplier array readout chip

200 papers

This paper presents a novel pixel chip readout scheme: the Region-of-Interest Readout Circuit (ROIRC), which is designed for large area, large array pixel chips and Gas Pixel Detector (GPD). This design employs a sentinel pixel detection…

Silicon Photomultipliers (SiPMs) are the state-of-the-art technology in single-photon detection with solid-state detectors. Single Photon Avalanche Diodes (SPADs), the key element of SiPMs, can now be manufactured in CMOS processes,…

The next generation of proton decay and neutrino experiments, the post-SuperKamiokande detectors as those that will take place in megaton size water tanks, will require very large surfaces of photodetection and a large volume of data. Even…

A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the…

Instrumentation and Detectors · Physics 2019-08-14 C. Schill

1 ps timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe a preliminary design for PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in the TSMC 65…

A dedicated front-end electronics has been developed for the trigger chambers of the ALICE muon spectrometer which will work at the future LHC at CERN. These trigger chambers are based on RPCs (Resistive Plate Chambers) working in streamer…

High Energy Physics - Phenomenology · Physics 2007-05-23 P. Rosnet , L. Royer , the Alice Collaboration

An Application Specific Integrated Circuit (ASIC), called RIGEL, designed for the sparse readout of a Silicon Pixel Drift Detector (PixDD) for space applications is presented.The low leakage current (less than 1 pA at +20 {\deg}C) and anode…

Instrumentation and Detectors · Physics 2022-08-09 Massimo Gandola , Marco Grassi , Filippo Mele , Irisa Dedolli , Piero Malcovati , Giuseppe Bertuccio

This work reports a cost-effective, multi-parameter readout and data-acquisition system for a muon scattering tomography system based on Resistive Plate Chambers (RPCs). Initial test measurements with a prototype Resistive Plate Chamber…

Instrumentation and Detectors · Physics 2022-06-01 Subhendu Das , Sridhar Tripathy , Sandip Sarkar , Nayana Majumdar , Supratik Mukhopadhyay

We present the final results from a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC). This detector was designed as a full-scale prototype of the particle identification system for the SuperB experiment [1], and comprises…

Instrumentation and Detectors · Physics 2015-12-09 B. Dey , M. Borsato , N. Arnaud , D. W. G. S. Leith , K. Nishimura , D. A. Roberts , B. N. Ratcliff , G. Varner , J. Va'vra

A complete dedicated electronics, from front-end to back-end, was developed to instrument a MIMAC prototype. A front end ASIC able to monitor 64 strips of pixels and to provide their individual "Time Over Threshold" information has been…

Instrumentation and Methods for Astrophysics · Physics 2012-02-20 O. Bourrion , G. Bosson , C. Grignon , J. P. Richer , O. Guillaudin , F. Mayet , J. Billard , D. Santos

We present the development of a single-photon detector and the connected read-out electronics. This `hybrid' detector is based on a vacuum tube, transmission photocathode, microchannel plate and a pixelated CMOS read-out anode encapsulating…

Instrumentation and Detectors · Physics 2022-07-06 J. A. Alozy , N. V. Biesuz , M. Campbell , V. Cavallini , A. Cotta Ramusino , M. Fiorini , M. Guarise , X. Llopart Cudie

Large-area silicon photomultipliers (SiPMs) are desired in many applications where large surfaces have to be covered. For instance, a large area SiPM has been developed by Hamamatsu Photonics in collaboration with the University of Geneva,…

Instrumentation and Methods for Astrophysics · Physics 2023-02-08 Nicolas De Angelis , David Gascón , Sergio Gómez , Matthieu Heller , Teresa Montaruli , Andrii Nagai

We report on the development of a front-end ASIC for silicon-strip detectors of the J-PARC Muon g-2/EDM experiment. This experiment aims to measure the muon anomalous magnetic moment and electric dipole moment precisely to explore new…

Instrumentation and Detectors · Physics 2019-01-30 Yuki Tsutsumi , Tetsuichi Kishishita , Yutaro Sato , Masayoshi Shoji , Manobu M. Tanaka , Tsutomu Mibe , Junji Tojo

A front-end readout electronics system has been developed for silicon strip detectors. The system uses an application specific integrated circuit (ASIC) ATHED to realize multi-channel E&T measurement. The slow control of ASIC chips is…

Instrumentation and Detectors · Physics 2011-06-13 Yi Qian , Hong Su , Jie Kong , Cheng-Fu Dong , Xiao-Li Ma , Xiao-Gang Li

A monolithic silicon pixel ASIC prototype, produced in 2024 as part of the Horizon 2020 MONOLITH ERC Advanced project, was tested with a 120 GeV/c pion beam. The ASIC features a matrix of hexagonal pixels with a 100 \mu m pitch, read by…

In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the…

Instrumentation and Detectors · Physics 2015-06-26 R. Bellazzini , F. Angelini , L. Baldini , F. Bitti , A. Brez , L. Latronico , M. M. Massai , M. Minuti , N. Omodei , M. Razzano , C. Sgro , G. Spandre , E. Costa , P. Soffitta

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted…

The present article introduces a novel ASIC architecture, designed in the context of the ATLAS Tile Calorimeter upgrade program for the High-Luminosity phase of the Large Hadron Collider at CERN. The architecture is based on…

Glass based Resistive Plate Chambers (RPCs) are going to be used as an active element in the Iron Calorimeter (ICAL) experiment at the India based Neutrino Observatory (INO), which is being constructed to study atmospheric neutrinos. Though…

Instrumentation and Detectors · Physics 2016-11-03 Ashok Kumar , Ankit Gaur , Aman Phogat , Md. Rafik , Md. Naimuddin

Reconfigurable photonic integrated circuits (PICs) can implement arbitrary operations and signal processing functionalities directly in the optical domain. Run-time configuration of these circuits requires an electronic control layer to…