English
Related papers

Related papers: Performance Study of the CMS Barrel Resistive Plat…

200 papers

A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this…

Instrumentation and Detectors · Physics 2022-12-21 Atsushi Oya , Kei Ieki , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Kensuke Yamamoto

The Resistive Plate Chamber (RPC) muon subsystem contributes significantly to the formation of the trigger decision and reconstruction of the muon trajectory parameters. Simulation of the RPC response is a crucial part of the entire CMS…

The CMS Collaboration conducted a month-long data taking exercise, the Cosmic Run At Four Tesla, during October-November 2008, with the goal of commissioning the experiment for extended operation. With all installed detector systems…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

The CMS detector is designed around a large 4 T superconducting solenoid, enclosed in a 12000-tonne steel return yoke. A detailed map of the magnetic field is required for the accurate simulation and reconstruction of physics events in the…

Instrumentation and Detectors · Physics 2012-08-27 The CMS Collaboration

Muons from cosmic-ray interactions in the atmosphere provide a high-statistics source of particles that can be used to study the performance and calibration of the ATLAS detector. Cosmic-ray muons can penetrate to the cavern and deposit…

Instrumentation and Detectors · Physics 2012-08-27 The ATLAS Collaboration

The alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

This document presents an overview of the activities of Brazilian groups on gaseous detectors, with emphasis on resistive plate chambers (RPCs) for the CMS experiment at the CERN LHC and related applications. It summarises the design,…

The ATLAS detector at the Large Hadron Collider has collected several hundred million cosmic ray events during 2008 and 2009. These data were used to commission the Muon Spectrometer and to study the performance of the trigger and tracking…

Instrumentation and Detectors · Physics 2012-08-27 The ATLAS Collaboration

The main results of the quality assurance tests performed on the Resistive Plate Chamber used by the ATLAS experiment at LHC as muon trigger chambers are reported and discussed. Since July 2004, about 270 RPC units has been certified at…

Resistive Plate Chambers (RPCs) are essential active media of large-scale experiments as part of the muon systems and (semi-)digital hadron calorimeters. Among the several outstanding issues associated with the RPCs, the loss of efficiency…

Instrumentation and Detectors · Physics 2023-07-19 Mehmet Tosun , Burak Bilki , Kutlu Kagan Sahbaz

The performance of all subsystems of the CMS muon detector has been studied by using a sample of proton--proton collision data at sqrt(s) = 7 TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40…

Instrumentation and Detectors · Physics 2014-03-12 The CMS Collaboration

The ALICE Muon IDentifier is composed of 72 single-gap bakelite Resistive Plate Chambers, which have been operational since 2009 in maxi-avalanche mode (discrimination threshold:7 mV without amplification) with a…

Instrumentation and Detectors · Physics 2024-03-21 Alessandro Ferretti

During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates,…

Instrumentation and Detectors · Physics 2022-01-19 A. Samalan , M. Tytgat , G. A. Alves , F. Marujo , F. Torres Da Silva De Araujo , E. M. DaCosta , D. De Jesus Damiao , H. Nogima , A. Santoro , S. Fonseca De Souza , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Rodozov , M. Shopova , G. Soultanov , M. Bonchev , A. Dimitrov , L. Litov , B. Pavlov , P. Petkov , A. Petrov , S. J. Qian , C. Bernal , A. Cabrera , J. Fraga , A. Sarkar , S. Elsayed , Y. Assran , M. El Sawy , M. A. Mahmoud , Y. Mohammed , C. Combaret , M. Gouzevitch , G. Grenier , I. Laktineh , L. Mirabito , K. Shchablo , I. Bagaturia , D. Lomidze , I. Lomidze , V. Bhatnagar , R. Gupta , P. Kumari , J. Singh , V. Amoozegar , B. Boghrati , M. Ebraimi , R. Ghasemi , M. Mohammadi Najafabadi , E. Zareian , M. Abbrescia , R. Aly , W. Elmetenawee , N. DeFilippis , A. Gelmi , G. Iaselli , S. Leszki , F. Loddo , I. Margjeka , G. Pugliese , D. Ramos , M. Caponero , L. Benussi , S. Bianco , S. Colafranceschi , A. Russo , L. Passamonti , D. Piccolo , D. Pierluigi , G. Saviano , S. Buontempo , A. Di Crescenzo , F. Fienga , G. DeLellis , L. Lista , S. Meola , P. Paolucci , A. Braghieri , P. Salvini , P. Montagna , C. Riccardi , P. Vitulo , B. Francois , T. J. Kim , J. Park , S. Y. Choi , B. Hong , K. S. Lee , J. Goh , H. Lee , J. Eysermans , C. Uribe Estrada , I. Pedraza , H. Castilla-Valdez , A. Sanchez-Hernandez , C. A. Mondragon Herrera , D. A. Perez Navarro , G. A. AyalaSanchez , S. Carrillo , E. Vazquez , N. Zaganidis , A. Radi , A. Ahmad , I. Asghar , H. Hoorani , S. Muhammad , M. A. Shah , B. Mandelli , R. Guida , I. Crotty

The CMS Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise. This paper describes the trigger components used, the algorithms that were…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

This work presents a novel cosmic-ray scattering experiment employing a Resistive Plate Chambers (RPC) muon tomography system. By introducing the scattering angle between incident and outgoing cosmic-ray tracks as a key observable, this…

Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in…

Instrumentation and Detectors · Physics 2015-09-08 M. Affatigato , U. Akgun , B. Bilki , F. Corriveau , B. Freund , N. Johnson , C. Neubueser , Y. Onel , J. Repond , L. Xia

The pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

The Muon Chamber (MuCh) is a sub-system of the Compressed Baryonic Matter (CBM) experiment for the detection of low-mass-vector mesons produced in high energy heavy-ion collisions at beam energies ranging from 2 AGeV to 11 AGeV and decaying…

Instrumentation and Detectors · Physics 2022-01-04 Mitali Mondal , Tanay Dey , Subhasis Chattopadhyay , Jogender Saini , Zubayer Ahammed

A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized…

Instrumentation and Detectors · Physics 2016-08-30 Dezső Varga , Gábor Nyitrai , Gergő Hamar , László Oláh

After years of development, the CMS distributed computing system is now in full operation. The LHC continues to set records for instantaneous luminosity, and CMS continues to record data at 300 Hz. Because of the intensity of the beams,…

Instrumentation and Detectors · Physics 2019-08-13 Kenneth Bloom