English
Related papers

Related papers: The PRIMA fringe sensor unit

200 papers

The fringe sensor unit (FSU) is the central element of the phase referenced imaging and micro-arcsecond astrometry (PRIMA) dual-feed facility for the Very Large Telescope interferometer (VLTI). It has been installed at the Paranal…

Instrumentation and Methods for Astrophysics · Physics 2015-03-17 J. Sahlmann , R. Abuter , S. Menardi , C. Schmid , N. Di Lieto , F. Delplancke , R. Frahm , N. Gomes , P. Haguenauer , S. Leveque , S. Morel , A. Mueller , T. Phan Duc , N. Schuhler , G. van Belle

Context: A turbulent atmosphere causes atmospheric piston variations leading to rapid changes in the optical path difference of an interferometer, which causes correlated flux losses. This leads to decreased sensitivity and accuracy in the…

Instrumentation and Methods for Astrophysics · Physics 2014-09-05 A. Müller , J. -U. Pott , A. Mérand , R. Abuter , F. Delplancke-Ströbele , Th. Henning , R. Köhler , Ch. Leinert , S. Morel , T. Phan Duc , E. Pozna , A. Ramirez , J. Sahlmann , C. Schmid

Measurement of interferometric parameters values is affected by phase disturbance due especially to atmospheric turbulences. Algorithms of fringe sensing, aimed at fringe parameters identification, are based on interferometric models that…

Instrumentation and Methods for Astrophysics · Physics 2009-08-27 Bonino Donata

The GRAVITY instrument has been commissioned on the VLTI during 2016 and is now available to the astronomical community. It is the first optical interferometer capable of observing sources as faint as magnitude 19 in K-band. This is…

Context. With the arrival of the next generation of ground-based imaging interferometers combining from 4 to possibly 6 telescopes simultaneously, there is also a strong need for a new generation of fringe trackers able to cophase such…

Instrumentation and Methods for Astrophysics · Physics 2015-05-27 N. Blind , O. Absil , J. -B. Lebouquin , J. -P. Berger , A. Chelli

The implementation of the simultaneous combination of several telescopes (from four to eight) available at Very Large Telescope Interferometer (VLTI) will allow the new generation interferometric instrumentation to achieve interferometric…

Astrophysics · Physics 2009-11-13 L. Corcione , D. Bonino , D. F. Busher , M. Gai , S. Ligori , D. Loreggia , G. Masssone , J. S. Young

In a few years, the second generation instruments of the Very Large Telescope Interferometer (VLTI) will routinely provide observations with 4 to 6 telescopes simultaneously. To reach their ultimate performance, they will need a fringe…

The VLTI Spectro Imager project aims to perform imaging with a temporal resolution of 1 night and with a maximum angular resolution of 1 milliarcsecond, making best use of the Very Large Telescope Interferometer capabilities. To fulfill the…

The limiting magnitude is a key issue for optical interferometry. Pairwise fringe trackers based on the integrated optics concepts used for example in GRAVITY seem limited to about K=10.5 with the 8m Unit Telescopes of the VLTI, and there…

The Sydney University Stellar Interferometer (SUSI) now incorporates a new beam combiner, called the Microarcsecond University of Sydney Companion Astrometry instrument (MUSCA), for the purpose of high precision differential astrometry of…

Instrumentation and Methods for Astrophysics · Physics 2013-12-02 Y. Kok , M. J. Ireland , P. G. Tuthill , J. G. Robertson , B. A. Warrington , A. C. Rizzuto , W. J. Tango

In the summer of 2011, the first on-sky astrometric commissioning of PRIMA-Astrometry delivered a performance of 3 m'' for a 10 '' separation on bright objects, orders of magnitude away from its exoplanet requirement of 50 {\mu}'' ~ 20…

At the Very Large Telescope Interferometer, the purpose of the fringe-tracker FINITO is to stabilize the optical path differences between the beams, allowing longer integration times on the scientific instruments AMBER and MIDI. Our goal is…

PHASECam is the Large Binocular Telescope Interferometer's (LBTI) phase sensor, a near-infrared camera which is used to measure tip/tilt and phase variations between the two AO-corrected apertures of the Large Binocular Telescope (LBT).…

Instrumentation and Methods for Astrophysics · Physics 2018-07-16 E. R. Maier , P. M. Hinz , D. Defrère , S. Ertel , E. Downey

PHASECam is the fringe tracker for the Large Binocular Telescope Interferometer (LBTI). It is a near-infrared camera which is used to measure both tip/tilt and fringe phase variations between the two adaptive optics (AO) corrected apertures…

Instrumentation and Methods for Astrophysics · Physics 2020-07-30 Erin R. Maier , Phil Hinz , Denis Defrère , Paul Grenz , Elwood Downey , Steve Ertel , Katie Morzinski , Ewan S. Douglas

We present the architectural concept for the Far-Infrared Enhanced Survey Spectrometer (FIRESS) for the Probe Mission for far-IR Astrophysics (PRIMA). FIRESS spans the 24--235 micron range with four R ~ 100 slit-fed grating modules, each…

Since April 2011, realtime fringe tracking data are recorded simultaneously with data from the VLTI/AMBER interferometric beam combiner. Not only this offers possibilities to post-process AMBER reduced data to obtain more accurate…

Instrumentation and Methods for Astrophysics · Physics 2015-06-12 A. Merand , F. Patru , J. -P. Berger , I. Percheron , S. Poupar

Fringe tracking in interferometers is typically analyzed with the implicit assumption that there is a single phase associated with each telescope in the array. If the telescopes have apertures significantly larger than r0 and only partial…

Astrophysics · Physics 2009-11-13 David F. Buscher , John S. Young , Fabien Baron , Christopher A. Haniff

FIRST (Fibered Imager foR a Single Telescope instrument) is a post-AO instrument that enables high contrast imaging and spectroscopy at spatial scales below the diffraction limit. FIRST achieves sensitivity and accuracy by a unique…

Instrumentation and Methods for Astrophysics · Physics 2021-02-15 K. Barjot , E. Huby , S. Vievard , N. Cvetojevic , S. Lacour , G. Martin , V. Deo , V. Lapeyrere , D. Rouan , O. Guyon , J. Lozi , N. Jovanovic , C. Cassagenettes , G. Perrin , F. Marchis , G. Duchêne , T. Kotani

We describe the fringe packet tracking system used to equalise the optical path lengths at the Infrared Optical Telescope Array (IOTA) interferometer. The measurement of closure phases requires obtaining fringes on three baselines…

The implementation of fringe tracking for optical interferometers is inevitable when optimal exploitation of the instrumental capacities is desired. Fringe tracking allows continuous fringe observation, considerably increasing the…

Instrumentation and Methods for Astrophysics · Physics 2015-06-04 J. Menu , G. Perrin , E. Choquet , S. Lacour
‹ Prev 1 2 3 10 Next ›