English
Related papers

Related papers: Improved Fast Neutron Spectroscopy via Detector Se…

200 papers

In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons impinging on…

Instrumentation and Detectors · Physics 2015-12-09 M. Osipenko , M. Ripani , G. Ricco , B. Caiffi , F. Pompili , M. Pillon , M. Angelone , G. Verona-Rinati , R. Cardarelli , G. Mila , S. Argiro

Building the European Spallation Source (ESS), the most powerful neutron source in the world, requires significant technological advances at most fronts of instrument component design. Detectors are not an exception. The existing…

Neutrino oscillation experiments often employ two identical detectors to minimize errors due to inadequately known neutrino beam. We examine various systematics effects related to the prediction of the neutrino spectrum in the `far'…

High Energy Physics - Experiment · Physics 2007-05-23 M. Szleper , A. Para

It is very important to measure the plasma performances of fusion reactors such as fuel ion density, plasma temperature, fusion power, fast neutron energy, and neutron flux. Various diagnostic systems are needed to measure fast neutron…

Nuclear Experiment · Physics 2024-07-10 Iskender Atilla Reyhancan

Large liquid-scintillator-based detectors have proven to be exceptionally effective for low energy neutrino measurements due to their good energy resolution and scalability to large volumes. The addition of directional information using…

Instrumentation and Detectors · Physics 2015-06-16 C. Aberle , A. Elagin , H. J. Frisch , M. Wetstein , L. Winslow

Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified…

A new instrument for high resolution imaging of fast-neutrons is presented here. It is designed for energy selective radiography in nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. The device presented here is based on hydrogenous…

We show data from a new type of detector that can be used to determine neutron flux, energy distribution, and direction of neutron motion for both fast and thermal neutrons. Many neutron detectors are plagued by large backgrounds from…

Scintillation light is used in liquid argon (LAr) neutrino detectors to provide a trigger signal, veto information against cosmic rays, and absolute event timing. In this work, we discuss additional opportunities offered by detectors with…

Instrumentation and Detectors · Physics 2015-01-27 M. Sorel

Compact neutron imagers using double-scatter kinematic reconstruction are being designed for localization and characterization of special nuclear material. These neutron imaging systems rely on scintillators with a rapid prompt temporal…

Instrumentation and Detectors · Physics 2020-09-16 T. A. Laplace , B. L. Goldblum , J. A. Brown , D. L. Bleuel , C. A. Brand , G. Gabella , T. Jordan , C. Moore , N. Munshi , Z. W. Sweger , A. Ureche , E. Brubaker

As photon counting detectors are being explored for medical and industrial imaging applications, there is a critical need to understand spectral characteristics of scattered x-ray photons. Scattered radiation is detrimental to x-ray imaging…

Medical Physics · Physics 2022-12-14 Cale E. Lewis , Mini Das

The scattering of neutrinos off dark matter can induce time delays in their propagation compared to that of photons, which would wash out correlations between ultra-high-energy neutrinos and electromagnetic observations of their sources -…

High Energy Physics - Phenomenology · Physics 2019-09-11 Seth Koren

Photonic computing promises faster and more energy-efficient deep neural network (DNN) inference than traditional digital hardware. Advances in photonic computing can have profound impacts on applications such as autonomous driving and…

Computer Vision and Pattern Recognition · Computer Science 2023-10-04 Lakshmi Nair , David Widemann , Brad Turcott , Nick Moore , Alexandra Wleklinski , Darius Bunandar , Ioannis Papavasileiou , Shihu Wang , Eric Logan

Liquid-scintillator-based detectors are a robust technology that scales well to large volumes. For this reason, they are attractive for experiments searching for neutrinoless double-beta decay. A combination of improved photo-detection…

Instrumentation and Detectors · Physics 2013-07-12 Lindley Winslow

A nearby core collapse supernova will produce a burst of neutrinos in several detectors worldwide. With reasonably high probability, the Earth will shadow the neutrino flux in one or more detectors. In such a case, for allowed oscillation…

Instrumentation and Methods for Astrophysics · Physics 2010-04-06 Kate Scholberg , Armin Burgmeier , Roger Wendell

This paper presents studies on application of convolutional neural network (CNN) to GEANT4 optical simulation data generated with a scintillator detector subdivided into 1 cubic cm, which is designed for the long-baseline neutrino…

Instrumentation and Detectors · Physics 2021-06-22 Tomohisa Ogawa

A new type of neutron detector, named Stack Structure Solid organic Scintillator (S$^4$), consisting of multi-layer plastic scintillators with capability to suppress low-energy $\gamma$ rays under high-counting rate has been constructed and…

Coincidence and time-of-flight measurement techniques are employed to tag fission neutrons emitted from a 252Cf source sealed on one side with a very thin layer of Au. The source is positioned within a gaseous 4He scintillator detector.…

Conceiving the possibility of using plastic scintillator bars as robust detectors for antineutrino detection for the remote reactor monitoring and nuclear safeguard application we study expected basic performance by Monte Carlo simulation.…

Instrumentation and Detectors · Physics 2016-10-20 A. Sh. Georgadze , V. M. Pavlovych , O. A. Ponkratenko , D. A. Litvinov

The characteristics of the Solid-state Neutron Detector, under development for neutron-scattering measurements at the European Spallation Source, have been simulated with a Geant4-based computer code. The code models the interations of…