English
Related papers

Related papers: The low-temperature energy calibration system for …

200 papers

The LUMINEU is designed to investigate the possibility to search for neutrinoless double beta decay in $^{100}$Mo by means of a large array of scintillating bolometers based on ZnMoO$_4$ crystals enriched in $^{100}$Mo. High energy…

The CUPID0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95$\%$ enriched in $^{82}$Se and 2 natural ZnSe crystals, started…

The technology of scintillating bolometers based on zinc molybdate (ZnMoO$_4$) crystals is under development within the LUMINEU project to search for 0$\nu$2$\beta$ decay of $^{100}$Mo with the goal to set the basis for large scale…

Cryogenic characterization of transition-edge sensor (TES) bolometers is a time- and labor-intensive process. As new experiments deploy larger and larger arrays of TES bolometers, the testing process will become more of a bottleneck. Thus…

Instrumentation and Methods for Astrophysics · Physics 2024-08-16 K. R. Ferguson , A. N. Bender , N. Whitehorn , T. W. Cecil

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the $Q$-value of the decay are essential. The LEGEND-200 experiment performs such a…

Instrumentation and Detectors · Physics 2023-02-02 L. Baudis , G. Benato , E. M. Bond , P. -J. Chiu , S. R. Elliott , R. Massarczyk , S. Meijer , Y. Müller

The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of a aluminum nucleus. The dynamic of such a process is well modeled by a two-body…

The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$\beta$ decay in $^{76}$Ge with an array of about 40 high-purity isotopically-enriched germanium detectors. The experimental signature of the decay is a…

Instrumentation and Detectors · Physics 2022-03-02 GERDA collaboration , M. Agostini , G. R. Araujo , A. M. Bakalyarov , M. Balata , I. Barabanov , L. Baudis , C. Bauer , E. Bellotti , S. Belogurov , A. Bettini , L. Bezrukov , V. Biancacci , E. Bossio , V. Bothe , V. Brudanin , R. Brugnera , A. Caldwell , C. Cattadori , A. Chernogorov , T. Comellato , V. D'Andrea , E. V. Demidova , N. Di Marco , E. Doroshkevich , F. Fischer , M. Fomina , A. Gangapshev , A. Garfagnini , C. Gooch , P. Grabmayr , V. Gurentsov , K. Gusev , J. Hakenmüller , S. Hemmer , R. Hiller , W. Hofmann , J. Huang , M. Hult , L. V. Inzhechik , J. Janicskó Csáthy , J. Jochum , M. Junker , V. Kazalov , Y. Kermaïdic , H. Khushbakht , T. Kihm , I. V. Kirpichnikov , A. Klimenko , R. Kneißl , K. T. Knöpfle , O. Kochetov , V. N. Kornoukhov , P. Krause , V. V. Kuzminov , M. Laubenstein , M. Lindner , I. Lippi , A. Lubashevskiy , B. Lubsandorzhiev , G. Lutter , C. Macolino , B. Majorovits , W. Maneschg , L. Manzanillas , M. Miloradovic , R. Mingazheva , M. Misiaszek , P. Moseev , Y. Müller , I. Nemchenok , L. Pandola , K. Pelczar , L. Pertoldi , P. Piseri , A. Pullia , C. Ransom , L. Rauscher , S. Riboldi , N. Rumyantseva , C. Sada , F. Salamida , S. Schönert , J. Schreiner , M. Schütt , A. -K. Schütz , O. Schulz , M. Schwarz , B. Schwingenheuer , O. Selivanenko , E. Shevchik , M. Shirchenko , L. Shtembari , H. Simgen , A. Smolnikov , D. Stukov , A. A. Vasenko , A. Veresnikova , C. Vignoli , K. von Sturm , T. Wester , C. Wiesinger , M. Wojcik , E. Yanovich , B. Zatschler , I. Zhitnikov , S. V. Zhukov , D. Zinatulina , A. Zschocke , A. J. Zsigmond , K. Zuber , G. Zuzel

The CUPID-Mo experiment, located at Laboratoire Souterrain de Modane (France), was a demonstrator experiment for CUPID. It consisted of an array of 20 Li$_2^{100}$MoO$_4$ (LMO) calorimeters each equipped with a Ge light detector (LD) for…

We report the performance of two prototype TeO2 macrobolometers, operated at ~25 mK, able to identify events due to energy deposited at the detector surface. This capability is obtained by thermally coupling thin Ge active layers to the…

Nuclear Experiment · Physics 2009-11-25 Luca Foggetta , Andrea Giuliani , Claudia Nones , Marisa Pedretti , Samuele Sangiorgio

The Short Baseline Near Detector (SBND) is one of three liquid argon (LAr) neutrino detectors sitting in the Booster Neutrino Beam (BNB) at Fermilab as part of the Short Baseline Neutrino (SBN) program. The detector is in a cryostat holding…

Instrumentation and Detectors · Physics 2019-10-16 Shanshan Gao

CUPID is a next-generation neutrinoless double-beta decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In…

The electro-magnetic calorimeter at the BaBar detector, part of the asymmetric B Factory at SLAC, measures photons in the energy range from 20 MeV to 8 GeV with good resolution. The calorimeter is calibrated at the low energy end with 6.13…

Instrumentation and Detectors · Physics 2019-08-14 Johannes M. Bauer

We present a new measurement of the 2nbb half-life of 130Te (T1/2) using the first complete model of the CUORE data, based on 1038 kg yr of collected exposure. Thanks to optimized data selection, we achieve a factor of two improvement in…

Nuclear Experiment · Physics 2025-04-01 D. Q. Adams , C. Alduino , K. Alfonso , F. T. Avignone , O. Azzolini , G. Bari , F. Bellini , G. Benato , M. Beretta , M. Biassoni , A. Branca , C. Brofferio , C. Bucci , J. Camilleri , A. Caminata , A. Campani , J. Cao , C. Capelli , S. Capelli , L. Cappelli , L. Cardani , P. Carniti , N. Casali , E. Celi , D. Chiesa , M. Clemenza , S. Copello , O. Cremonesi , R. J. Creswick , A. D'Addabbo , I. Dafinei , S. Dell'Oro , S. Di Domizio , S. Di Lorenzo , T. Dixon , D. Q. Fang , G. Fantini , M. Faverzani , E. Ferri , F. Ferroni , E. Fiorini , M. A. Franceschi , S. J. Freedman , S. H. Fu , B. K. Fujikawa , S. Ghislandi , A. Giachero , M. Girola , L. Gironi , A. Giuliani , P. Gorla , C. Gotti , P. V. Guillaumon , T. D. Gutierrez , K. Han , E. V. Hansen , K. M. Heeger , D. L. Helis , H. Z. Huang , G. Keppel , Yu. G. Kolomensky , R. Kowalski , R. Liu , L. Ma , Y. G. Ma , L. Marini , R. H. Maruyama , D. Mayer , Y. Mei , M. N. Moore , T. Napolitano , M. Nastasi , C. Nones , E. B. Norman , A. Nucciotti , I. Nutini , T. O'Donnell , M. Olmi , B. T. Oregui , S. Pagan , C. E. Pagliarone , L. Pagnanini , M. Pallavicini , L. Pattavina , M. Pavan , G. Pessina , V. Pettinacci , C. Pira , S. Pirro , E. G. Pottebaum , S. Pozzi , E. Previtali , A. Puiu , S. Quitadamo , A. Ressa , C. Rosenfeld , B. Schmidt , A. Shaikina , V. Sharma , V. Singh , M. Sisti , D. Speller , P. T. Surukuchi , L. Taffarello , C. Tomei , A. Torres , J. A. Torres , K. J. Vetter , M. Vignati , S. L. Wagaarachchi , B. Welliver , K. Wilson , J. Wilson , L. A. Winslow , F. Xie , T. Zhu , S. Zimmermann , S. Zucchelli , D. Castillo , J. Kotila , J. Menendez. O. Nitescu , F. Simkovic

We demonstrate that Neganov-Luke amplified cryogenic light detectors with Transition Edge Sensor read-out can be applied for the background suppression in cryogenic experiments searching for the neutrinoless double beta decay of…

The present dissertation describes design, qualification and operation of several electronic instrumentations for High Energy Particle Physics experiments (LHCb) and Neutrino Physics experiments (CUORE and CUPID). Starting from 2019, the…

Instrumentation and Detectors · Physics 2018-08-31 Paolo Carniti

The CUPID-0 experiment searches for neutrinoless double beta decay ($0\nu\beta\beta$) using the first array of enriched Zn$^{82}$Se scintillating bolometers with double (heat and light) read-out. To further enhance the CUPID-0 detector…

Future experiments at high energy $e^+e^-$ colliders will focus on extremely precise Standard Model measurements. Among the most important physics benchmarks, there is the capability to resolve the Higgs decays into W or Z pairs, in their…

High Energy Physics - Experiment · Physics 2023-11-17 Andrea Pareti

We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0\nu\beta\beta$) that will use a 5-tonne, monolithic liquid…

Instrumentation and Detectors · Physics 2022-08-03 B. G. Lenardo , C. A. Hardy , R. H. M. Tsang , J. C. Nzobadila Ondze , A. Piepke , S. Triambak , A. Jamil , G. Adhikari , S. Al Kharusi , E. Angelico , I. J. Arnquist , V. Belov , E. P. Bernard , A. Bhat , T. Bhatta , A. Bolotnikov , P. A. Breur , J. P. Brodsky , E. Brown , T. Brunner , E. Caden , G. F. Cao , L. Cao , B. Chana , S. A. Charlebois , D. Chernyak , M. Chiu , J. R. Cohen , R. Collister , J. Dalmasson , T. Daniels , L. Darroch , R. DeVoe , M. L. di Vacri , Y. Y. Ding , M. J. Dolinski , J. Echevers , B. Eckert , M. Elbeltagi , L. Fabris , D. Fairbank , W. Fairbank , J. Farine , Y. S. Fu , G. Gallina , P. Gautam , G. Giacomini , W. Gillis , C. Gingras , R. Gornea , G. Gratta , K. Harouaka , M. Heffner , E. Hein , J. Hößl , A. House , A. Iverson , X. S. Jiang , A. Karelin , L. J. Kaufman , R. Krücken , A. Kuchenkov , K. S. Kumar , A. Larson , K. G. Leach , D. S. Leonard , G. Li , S. Li , Z. Li , C. Licciardi , R. Lindsay , R. MacLellan , J. Masbou , K. McMichael , M. Medina Peregrina , B. Mong , D. C. Moore , K. Murray , J. Nattress , C. R. Natzke , X. E. Ngwadla , K. Ni , Z. Ning , J. L. Orrell , G. S. Ortega , I. Ostrovskiy , C. T. Overman , A. Perna , T. Pinto Franco , A. Pocar , J. F. Pratte , N. Priel , E. Raguzin , G. J. Ramonnye , H. Rasiwala , K. Raymond , G. Richardson , M. Richman , J. Ringuette , P. C. Rowson , R. Saldanha , S. Sangiorgio , X. Shang , A. K. Soma , F. Spadoni , V. Stekhanov , X. L. Sun , S. Thibado , A. Tidball , J. Todd , T. Totev , O. A. Tyuka , F. Vachon , V. Veeraraghavan , S. Viel , K. Wamba , Y. Wang , Q. Wang , W. Wei , L. J. Wen , U. Wichoski , S. Wilde , W. H. Wu , W. Yan , L. Yang , O. Zeldovich , J. Zhao , T. Ziegler

Future sky surveys in the mm/sub-mm range, like the forthcoming balloon-borne missions LSPE, OLIMPO, SPIDER etc., will need detectors insensitive to cosmic rays (CRs) and with a NEP of the order of $10^{-17} \div 10^{-18}\,$W/sqrt(Hz). The…

Instrumentation and Methods for Astrophysics · Physics 2014-10-23 Maria Salatino , Paolo de Bernardis , Sumedh Mahashabde , Leonid S. Kuzmin , Silvia Masi

A cryogenic quantum dot thermometer is calibrated and operated using only a single non-galvanic gate connection. The thermometer is probed with radio-frequency reflectometry and calibrated by fitting a physical model to the phase of the…

Mesoscale and Nanoscale Physics · Physics 2021-03-24 J. M. A. Chawner , S. Barraud , M. F. Gonzalez-Zalba , S. Holt , E. A. Laird , Yu. A. Pashkin , J. R. Prance