The thermal performance of high heat flux components in a fusion reactor could be enhanced significantly by the use of nanofluid coolants, suspensions of a liquid with low concentrations of solid nanoparticles. However, before they are…

Instrumentation and Detectors · Physics 2013-11-21 T R Barrett , S Robinson , K Flinders , A Sergis , Y Hardalupas

Micro-channel cooling initially aiming at small-sized high-power integrated circuits is being transferred to the field of high energy physics. Today`s prospects of micro-fabricating silicon opens a door to a more direct cooling of detector…

Liquid xenon detectors such as XENON10 and XENON100 obtain a significant fraction of their sensitivity to light (<10 GeV) particle dark matter by looking for nuclear recoils of only a few keV, just above the detector threshold. Yet in this…

Instrumentation and Methods for Astrophysics · Physics 2011-01-27 Peter Sorensen

We present a comprehensive characterization of cold molecular beams from a cryogenic buffer-gas cell, providing an insight into the physics of buffer-gas cooling. Cold molecular beams are extracted from a cryogenic cell by electrostatic…

Chemical Physics · Physics 2018-12-04 X. Wu , T. Gantner , M. Zeppenfeld , S. Chervenkov , G. Rempe

This master thesis presents a new type of Positron Emission TOF Apparatus using Liquid xenOn (PETALO). The detector is based in the Liquid Xenon Scintillating Cell (LXSC). The cell is a box filled with liquid xenon (LXe) whose transverse…

Medical Physics · Physics 2016-06-01 J. M. Benlloch-Rodriguez

A difficult task with many particle detectors focusing on interactions below ~100 keV is to perform a calibration in the appropriate energy range that adequately probes all regions of the detector. Because detector response can vary greatly…

Instrumentation and Methods for Astrophysics · Physics 2010-07-23 A. Manalaysay , T. Marrodan Undagoitia , A. Askin , L. Baudis , A. Behrens , A. D. Ferella , A. Kish , O. Lebeda , R. Santorelli , D. Venos , A. Vollhardt

The XENON1T experiment aims for the direct detection of dark matter in a cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be…

Instrumentation and Detectors · Physics 2017-05-09 XENON Collaboration , E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , F. Arneodo , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , E. Duchovni , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , D. Franco , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , R. Itay , B. Kaminsky , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , M. Le Calloch , Q. Lin , S. Lindemann , M. Lindner , J. A. M. Lopes A. Manfredini , I. Maris , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , Y. Meng , M. Messina , K. Micheneau , B. Miguez , A. Molinario , M. Murra , J. Naganoma , K. Ni , U. Oberlack , S. E. A. Orrigo , P. Pakarha , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , M. -C. Piro , V. Pizzella , G. Plante , N. Priel , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , S. Rosendahl , N. Rupp , R. Saldanha , J. M. F. dos Santos , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , A. Stein , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , N. Upole , H. Wang , Y. Wei , C. Weinheimer , J. Wulf , J. Ye , Y. Zhang , I. Cristescu

A model of a multilayer device with non-trivial geometrical structure and nonlinear dependencies of thermodynamic material properties at cryogenic temperatures is suggested. A considered device, called cryogenic cell, is intended for use in…

Computational Physics · Physics 2015-11-20 Alexander Ayriyan , Jan Busa , Eugeny E. Donets , Hovik Grigorian , Jan Pribis

We developed a system that continuously maintains a cryocooler for long periods on a rotating table. A cryostat that holds the cryocooler is set on the table. A compressor is located on the ground and supplies high-purity (> 99.999%) and…

Instrumentation and Methods for Astrophysics · Physics 2014-07-21 Shugo Oguri , Jihoon Choi , Masanori Kawai , Osamu Tajima

We explore a method for laser cooling and optical detection of excitations in a LC electrical circuit. Our approach uses a nanomechanical oscillator as a transducer between optical and electronic excitations. An experimentally feasible…

Quantum Physics · Physics 2012-10-12 J. M. Taylor , A. S. Sørensen , C. M. Marcus , E. S. Polzik

The present state-of-the-art in cooling mechanical resonators is a version of "sideband" cooling. Here we present a method that uses the same configuration as sideband cooling --- coupling the resonator to be cooled to a second microwave…

Quantum Physics · Physics 2015-05-27 Xiaoting Wang , Sai Vinjanampathy , Frederick W. Strauch , Kurt Jacobs

The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically…

This paper describes a novel integrated circuit technology to manufacture high-density thermoelectric devices on a semiconductor wafer. With no moving parts, a thermoelectric cooler operates quietly, allows cooling below ambient…

General Physics · Physics 2008-01-08 H. Chen , L. Hsu , X. Wei

We report initial NMR studies of continuous flow laser-polarized xenon gas, both in unrestricted tubing, and in a model porous media. The study uses Pulsed Gradient Spin Echo-based techniques in the gas-phase, with the aim of obtaining more…

Soft Condensed Matter · Physics 2007-05-23 R. W. Mair , R. Wang , M. S. Rosen , D. Candela , D. G. Cory , R. L. Walsworth

A detector using liquid Xenon (LXe) in the scintillation mode is studied for Positron Emission Tomography (PET) of small animals. Its specific design aims at taking full advantage of the Liquid Xenon scintillation properties. This paper…

We report the creation of an ultracold neutral plasma by photoionization of laser-cooled xenon atoms. The charge carrier density is as high as 2 x 10^9 cm^-3, and the temperatures of electrons and ions are as low as 100 mK and 10 uK,…

Plasma Physics · Physics 2009-10-31 T. C. Killian , S. Kulin , S. D. Bergeson , L. A. Orozco , C. Orzel , S. L. Rolston

nEXO is a proposed next-generation experiment searching for the neutrinoless double beta decay of $^{136}$Xe using a tonne-scale liquid xenon (LXe) time projection chamber (TPC). To image the ionization signals from events in the liquid…

Instrumentation and Detectors · Physics 2025-12-15 Z. Li , M. Yu , E. Angelico , A. Atencio , A. Gupta , P. Knauss , A. Pena-Perez , B. G. Lenardo , P. Acharya , A. Amy , A. Anker , I. J. Arnquist , J. Bane , V. Belov , T. Bhatta , A. Bolotnikov , J. Breslin , P. A. Breur , J. P. Brodsky , E. Brown , T. Brunner , B. Burnell , E. Caden , G. F. Cao , L. Q. Cao , D. Cesmecioglu , D. Chernyak , M. Chiu , R. Collister , M. Marquis , T. Daniels , L. Darroch , R. DeVoe , M. L. di Vacri , X. Defay , Y. Y. Ding , D. Doering , M. J. Dolinski , A. Dragone , B. Eckert , A. Emara , N. Fatemighomi , W. Fairbank , B. T. Foust , D. Gallacher , N. Gallice , A. Gaur , W. Gillis , F. Girard , A. Gorham , K. Gracequist , G. Gratta , C. A. Hardy , J. Hasi , S. Hedges , M. Heffner , E. Hein , H. Hernandez Herrera , J. D. Holt , A. Iverson , X. S. Jiang , A. Karelin , D. Keblbeck , C. Kenney , I. Kotov , A. Kuchenkov , K. S. Kumar , S. Lavoie , A. Larson , M. B. Latif , K. G. Leach , D. S. Leonard , G. Lessard , K. K. H. Leung , G. Li , X. Li , C. Licciardi , R. Lindsay , R. MacLellan , S. Majidi , C. Malbrunot , B. Markovic , J. Masbou , M. Medina-Peregrina , S. Mngonyama , B. Mong , D. C. Moore , K. Ni , I. Nitu , A. Nolan , S. C. Nowicki , J. C. Nzobadila Ondze , A. Odian , J. L. Orrell , G. S. Ortega , L. Pagani , H. Peltz Smalley , A. Piepke , A. Pocar , S. Prentice , V. Radeka , E. Raguzin , R. Rai , H. Rasiwala , D. Ray , B. Reese , S. Rescia , F. Retiere , G. Richardson , V. Riot , R. Ross , L. Rota , P. C. Rowson , R. Saldanha , S. Sangiorgio , S. Sekula , T. Shetty , L. Si , F. Spadoni , V. Stekhanov , X. L. Sun , S. Thibado , T. Totev , S. Triambak , R. H. M. Tsang , O. A. Tyuka , T. Vallivilayil John , E. van Bruggen , M. Vidal , S. Viel , M. Walent , H. Wang , Q. D. Wang , M. Watts , W. Wei , M. Wehrfritz , L. J. Wen , S. Wilde , X. M. Wu , H. Xu , H. B. Yang , L. Yang , O. Zeldovich , J. Zhao

The PANCAKE facility is the world's largest liquid xenon test platform. Inside its cryostat with an internal diameter of 2.75 m, components for the next generation of liquid xenon experiments, such as DARWIN or XLZD, will be tested at their…