English
Related papers

Related papers: Test Measurements of Prototype Counters for CLAS12…

200 papers

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Instrumentation and Detectors · Physics 2016-04-19 J. W. Zhao , B. H. Sun , I. Tanihata , S. Terashima , L. H. Zhu , A. Enomoto , D. Nagae , T. Nishimura , S. Omika , A. Ozawa , Y. Takeuchi , T. Yamaguchi

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

Accurate Time-of-Flight (TOF) measurement with sub-100 picosecond resolution is a critical requirement for particle identification in future high-energy physics experiments, such as the Belle II $K_{L}$ and Muon (KLM) detector upgrade.…

Instrumentation and Detectors · Physics 2026-05-14 Ziyi Yang , Xiyang Wang , Shiming Zou , Ting Wang , Kairui Huang , Wanyi Zhuang , Yicheng Pu , Xiaolong Wang

In the CBM (Compressed Baryonic Matter) experiment constructed at the Facility for Anti-proton and Ion Research (Fair) at GSI, Darmstadt, Germany, MRPC(Multi-gap Resistive Plate Chamber) is adopted to construct the large TOF…

A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $\sigma_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with…

Instrumentation and Detectors · Physics 2016-05-23 P. W. Cattaneo , M. De Gerone , F. Gatti , M. Nishimura , W. Ootani , M. Rossella , S. Shirabe , Y. Uchiyama

The Time-of-Flight (TOF) system of the AMS detector gives the fast trigger to the read out electronics and measures velocity, direction and charge of the crossing particles. The new version of the detector (called AMS-02) will be installed…

High Energy Physics - Experiment · Physics 2017-08-23 L. Brocco , D. Casadei , F. Cindolo , A. Contin , G. Laurenti , G. Levi , A. Montanari , F. Palmonari , L. Patuelli , C. Sbarra , A. Zichichi

Time-of-flight (ToF) measurements is a possible alternative to anti-scatter grids in computed tomography (CT). Simulations have shown a possible 75% reduction in the detrimental scattering contribution with a 100 ps FWHM timing resolution.…

To achieve high precision and accuracy for mass measurements of exotic nuclei by Time-of-flight (TOF) methods: high-resolution beam-line magnetic-rigidity time-of-flight (B$\rho$-TOF) and in-ring isochronous mass spectrometry (IMS), a…

Instrumentation and Detectors · Physics 2024-07-16 Zhuang Ge

The CLAS detector will require improvements in its particle identification system to take advantage of the higher energies provided by the Jefferson Laboratory accelerator upgrade to 12 GeV. To this end, we have studied the timing…

Nuclear Experiment · Physics 2011-02-11 V. Baturin , V. Burkert , W. Kim , S. Majewsky , D. Nekrasov , K. Park , V. Popov , E. S. Smith , D. Son , S. S. Stepanyan , C. Zorn

The aim of this work is to develop high precision Time-of-Flight (TOF) devices based on high refractive index solid Cherenkov radiators read out by silicon photomultipliers (SiPMs). Cherenkov light is prompt and therefore ideal for reaching…

We study the possibility to use the Cherenkov light for the efficient detection of 511 keV photons with the goal to use it in TOF-PET. We designed and tested two detection modules consisting of PbF$_2$ crystals attached to Planacon MCP-PMT…

Instrumentation and Detectors · Physics 2020-03-24 C. Canot , M. Alokhina , P. Abbon , J. P. Bard , D. Breton , E. Delagnes , J. Maalmi , G. Tauzin , D. Yvon , V. Sharyy

A large area Resistive Plate Chamber (RPC) with a total active surface of 160x10 cm2 was built and tested. The surface was segmented in two 5 cm wide strips readout on both ends with custom, very high frequency, front end electronics. A…

Instrumentation and Detectors · Physics 2009-11-07 A. Blanco , R. Ferreira-Marques , Ch. Finck , P. Fonte , A. Gobbi , A. Policarpo , M. Rozas

In this work, we report on the timing performances of the Time-Of-Flight (TOF) apparatus of the FRACAS large acceptance mass spectrometer designed to measure the fragmentation cross sections of a $^{12}$C beam in hadrontherapy. The TOF…

Instrumentation and Detectors · Physics 2020-02-13 S. Salvador , E. Barlerin , J. Perronnel , C. Vandamme

Time-Of-Flight (TOF) is a noble technique that is used in Positron Emission Tomography (PET) imaging worldwide. The scintillator based imaging system that is being used around the world for TOF-PET is very expensive. Multi-gap Resistive…

Instrumentation and Detectors · Physics 2018-07-02 Rajesh Ganai , Shaifali Mehta , Mehulkumar Shiroya , Mitali Mondal , Zubayer Ahammed , Subhasis Chattopadhyay

Multi-gap RPC prototypes with readout on a multi-strip electrode were developed for the small polar angle region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The prototypes are based on low…

Measurement of the Time-of-Flight (TOF) of the 511 keV gammas brings an important reduction of statistical noise in the PET image, with higher precision time measurements producing clearer images. Scintillating crystals are used to convert…

Instrumentation and Detectors · Physics 2019-12-03 K. Doroud , Z. Liu , M. C. S. Williams

Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $\times$ 50 $\times$…

The Compressed Baryonic Matter (CBM) experiment is one of the major scientific spectrometers of the future Facility for Antiproton and Ion Research (FAIR) in Darmstadt. As one of the core sub-systems in CBM experiment for charged hadron…

Instrumentation and Detectors · Physics 2023-09-01 K. Wang , J. Zhou , X. Wang , X. Li , D. Hu , Y. Sun

The use of precise time-of-flight (ToF) detectors for measurements of diffractive and electromagnetic processes in proton-proton collisions is discussed. The performance of background rejection exploiting the ToF measurements of the forward…

High Energy Physics - Experiment · Physics 2019-06-26 Rafał Staszewski , Janusz J. Chwastowski

In order to further enhance the particle identification capability of the Beijing Spectrometer (BESIII), it is proposed to upgrade the current end-cap time-of-flight (eTOF) detector with multi-gap resistive plate chamber (MRPC). The…

Instrumentation and Detectors · Physics 2014-12-16 S. Yang , Y. J. Sun , C. Li , Y. K. Heng , S. Qian , H. F. Chen , T. X. Chen , H. L. Dai , H. H. Fan , S. B. Liu , S. D. Liu , X. S. Jiang , M. Shao , Z. B. Tang , H. Zhang , Z. G. Zhao
‹ Prev 1 2 3 10 Next ›