English
Related papers

Related papers: A Regenerable Filter for Liquid Argon Purification

200 papers

The liquid argon calorimeter is a key component of the ATLAS detector installed at the CERN Large Hadron Collider. The primary purpose of this calorimeter is the measurement of electrons and photons. It also provides a crucial input for…

High Energy Physics - Experiment · Physics 2014-07-25 ATLAS Collaboration

This paper will discuss a new method of signal read-out from photon detectors in ultra-large, underground liquid argon time projection chambers. In this design, the signal from the light collection system is coupled via capacitive plates to…

Instrumentation and Detectors · Physics 2016-04-13 Z. Moss , M. Toups , L. Bugel , G. H. Collin , J. M. Conrad

It is well known that the non-thermal plasma processes using electrical discharge or electron beam are effective for the environmental pollutant removal. Especially, the electron beam can efficiently remove pollutant, because a lot of…

Plasma Physics · Physics 2007-05-23 Masato Watanabe , Yu Wang , Akitoshi Okino , Kwang-Cheol Ko , Eiki Hotta

A scalable line of liquid argon TPC detectors is described, based on a three dimensional cubic frame array immersed on a common liquid argon volume. The paper describes general lines, main construction criteria, crucial points, parameters…

Astrophysics · Physics 2009-03-20 David B. Cline , Fabrizio Raffaelli , Franco Sergiampietri

This Letter details a measurement of the ionization yield ($Q_y$) of 6.7 keV $^{40}Ar$ atoms stopping in a liquid argon detector. The $Q_y$ of 3.6-6.3 detected $e^{-}/\mbox{keV}$, for applied electric fields in the range 240--2130 V/cm, is…

A hypothesis is proposed to explain the long-standing DAMA/LIBRA puzzle. Introduced into the DAMA/LIBRA shielding is a purge gas of nominally high-purity nitrogen, which under this hypothesis contains argon impurities. Argon is introduced…

High Energy Physics - Experiment · Physics 2018-03-28 D. N. McKinsey

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, USA. The ICARUS T600 detector is made of four large Time Projection Chambers,…

High Energy Physics - Experiment · Physics 2026-04-13 F. Abd Alrahman , P. Abratenko , N. Abrego-Martinez , A. Aduszkiewicz , F. Akbar , L. Aliaga Soplin , M. Artero Pons , J. Asaadi , W. F. Badgett , B. Behera , V. Bellini , R. Benocci , J. Berger , S. Berkman , O. Beltramello , S. Bertolucci , M. Betancourt , A. Blanchet , F. Boffelli , M. Bonesini , T. Boone , B. Bottino , A. Braggiotti , J. Bremer , S. J. Brice , V. Brio , C. Brizzolari , H. S. Budd , A. Campani , A. Campos , D. Carber , M. Carneiro , I. Caro Terrazas , H. Carranza , F. Castillo Fernandez , A. Castro , S. Centro , G. Cerati , M. Chalifour , P. Chambouvet , A. Chatterjee , D. Cherdack , S. Cherubini , N. Chithirasreemadam , T. E. Coan , A. Cocco , M. R. Convery , L. Cooper-Troendle , S. Copello , H. Da Motta , M. Dallolio , A. A. Dange , A. de Roeck , S. Di Domizio , L. Di Noto , D. Di Ferdinando , M. Diwan , S. Dolan , L. Domine , S. Donati , R. Doubnik , F. Drielsma , J. Dyer , S. Dytman , C. Fabre , A. Falcone , C. Farnese , A. Fava , N. Gallice , F. G. Garcia , C. Gatto , M. Geynisman , D. Gibin , A. Gioiosa , W. Gu , A. Guglielmi , G. Gurung , K. Hassinin , H. Hausner , A. Heggestuen , B. Howard , R. Howell , Z. Hulcher , I. Ingratta , C. James , W. Jang , Y. -J. Jwa , L. Kashur , W. Ketchum , J. S. Kim , D. -H. Koh , J. Larkin , Y. Li , C. Mariani , C. M. Marshall , S. Martynenko , N. Mauri , K. S. McFarland , D. P. Méndez , A. Menegolli , G. Meng , O. G. Miranda , D. Mladenov , A. Mogan , N. Moggi , E. Montagna , C. Montanari , A. Montanari , M. Mooney , G. Moreno-Granados , J. Mueller , M. Murphy , D. Naples , M. Nessi , T. Nichols , S. Palestini , M. Pallavicini , V. Paolone , L. Pasqualini , L. Patrizii , L. Paudel , G. Petrillo , C. Petta , V. Pia , F. Pietropaolo , F. Poppi , M. Pozzato , M. L Pumo , G. Putnam , X. Qian , A. Rappoldi , G. L. Raselli , S. Repetto , F. Resnati , A. M. Ricci , E. Richards , M. Rosenberg , M. Rossella , N. Rowe , P. Roy , C. Rubbia , M. Saad , S. Saha , G. Salmoria , S. Samanta , M. Satgia , A. Scaramelli , D. Schmit , F. Schwartz , A. Schukraft , D. Senadheera , S-H. Seo , F. Sergiampietri , G. Sirri , J. S. Smedley , J. Smith , L. Stanco , J. Stewart , H. A. Tanaka , F. Tapia , M. Tenti , K. Terao , F. Terranova , V. Togo , D. Torretta , M. Torti , F. Tortorici , R. Triozzi , Y. -T. Tsai , K. V. Tsang , S. Tufanli , T. Usher , F. Varanini , N. Vardy , S. Ventura , M. Vicenzi , C. Vignoli , B. Viren , F. A. Wieler , Z. Williams , R. J. Wilson , P. Wilson , J. Wolfs , T. Wongjirad , A. Wood , E. Worcester , M. Worcester , M. Wospakrik , S. Yadav , H. Yu , J. Yu , A. Zani , J. Zennamo , J. Zettlemoyer , C. Zhang , S. Zucchelli , M. Zuckerbrot

The scintillation light yield of liquid argon from nuclear recoils relative to electronic recoils has been measured as a function of recoil energy from 10 keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the…

Instrumentation and Detectors · Physics 2013-05-30 D. Gastler , E. Kearns , A. Hime , L. C. Stonehill , S. Seibert , J. Klein , W. H. Lippincott , D. N. McKinsey , J. A. Nikkel

The high-luminosity phase of the Large Hadron Collider will provide 5-7 times greater luminosities than assumed in the original detector design. An improved trigger system requires an upgrade of the readout electronics of the ATLAS Liquid…

Instrumentation and Detectors · Physics 2020-09-16 Tiankuan Liu

The CAEN V1751 is a new generation of Waveform Digitizer recently introduced by CAEN SpA. It features 8 Channels per board, 10 bit, 1 GS/s using Flash ADCs Waveform Digitizers (or 4 channels at 2 GS/s in Dual Edge Sampling mode) with…

Instrumentation and Methods for Astrophysics · Physics 2012-07-03 R. Acciarri , N. Canci , F. Cavanna , A. Cortopassi , M. D'Incecco , G. Mini , F. Pietropaolo , A. Romboli , E. Segreto , A. M. Szelc

The MiniCLEAN dark matter experiment will exploit a single-phase liquid-argon detector instrumented with photomultiplier tubes submerged in the cryogen with nearly 4pi coverage of a 500 kg (150 kg) target (fiducial) mass. The high light…

Instrumentation and Detectors · Physics 2011-10-06 Andrew Hime

We present a cryogenic source of periodic streams of micrometer-sized hydrogen and argon droplets as ideal mass-limited target systems for fundamental intense laser-driven plasma applications. The highly compact design combined with a high…

The MuCap experiment is a high-precision measurement of the rate for the basic electroweak process of muon capture, mu- + p -> n + nu . The experimental approach is based on an active target consisting of a time projection chamber (TPC)…

Automatic resonance alignment tuning is performed in high-order series coupled microring filters using a feedback system. By inputting only a reference wavelength, a filter is tuned such that passband ripples are dramatically reduced…

The capabilities of liquid argon time projection chambers (LArTPCs) to reconstruct the spatial and calorimetric information of neutrino events have made them the detectors of choice in a number of experiments, specifically those looking to…

For the first time, planar high-purity germanium detectors with thin amorphous germanium contacts were successfully operated directly in liquid nitrogen and liquid argon in a cryostat at the Max-Planck-Institut fuer Physics in Munich. The…

Instrumentation and Detectors · Physics 2020-08-04 R. Panth , J. Liu , I. Abt , X. Liu , O. Schulz , W. -Z. Wei , H. Mei , D. -M. Mei , G. -J. Wang

This paper describes the design, realization and operation of a prototype liquid Argon Time Projection Chamber (LAr TPC) detector dedicated to the development of a novel online monitoring and calibration system exploiting UV laser beams. In…

We fabricated a 302 mm diameter low-pass filter made of alumina that has an anti-reflection coating (ARC) made with laser-ablated sub-wavelength structures (SWS). The filter has been integrated into and is operating with the MUSTANG2…

Water is a life-giving source, fundamental to human existence, yet, over a billion people lack access to clean drinking water. Present techniques for water treatment such as piped, treated water rely on time and resource intensive…

Chemical Physics · Physics 2016-07-26 Venkatasubramanian Viswanathan , Heine A. Hansen , Jens K. Nørskov

Nitrogen doping treatment with the subsequent electropolishing (EP) of the niobium superconducting cavity can significantly increase the cavity's quality factor up to a factor of 3. But the process of the EP removal may reintroduce hydrogen…

Accelerator Physics · Physics 2015-08-27 Ziqin Yang , Xiangyang Lu , Datao Xie , Lin Lin , Kui Zhou , Jifei Zhao , Deyu Yang , Weiwei Tan
‹ Prev 1 8 9 10 Next ›