English
Related papers

Related papers: Response of the CALICE Si-W Electromagnetic Calori…

200 papers

A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL for International Large Detector concept, one of the two detector concepts for the future International Linear Collider.…

Instrumentation and Detectors · Physics 2021-09-03 Fabricio Jimenez Morales

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high…

Instrumentation and Detectors · Physics 2009-09-29 CALICE Collaboration , J. Repond , J. Yu , C. M. Hawkes , Y. Mikami , O. Miller , N. K. Watson , J. A. Wilson , G. Mavromanolakis , M. A. Thomson , D. R. Ward , W. Yan , F. Badaud , D. Boumediene , C. Carloganu , R. Cornat , P. Gay , Ph. Gris , S. Manen , F. Morisseau , L. Royer , G. C. Blazey , D. Chakraborty , A. Dyshkant , K. Francis , D. Hedin , G. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , E. Garutti , V. Korbel , F. Sefkow , M. Groll , G. Kim , D-W. Kim , K. Lee , S. Lee , K. Kawagoe , Y. Tamura , D. A. Bowerman , P. D. Dauncey , A. -M. Magnan , C. Noronha , H. Yilmaz , O. Zorba , V. Bartsch , J. M. Butterworth , M. Postranecky , M. Warren , M. Wing , M. Faucci Giannelli , M. G. Green , F. Salvatore , T. Wu , D. Bailey , R. J. Barlow , M. Kelly , S. Snow , R. J. Thompson , M. Danilov , V. Kochetkov , N. Baranova , P. Ermolov , D. Karmanov , M. Korolev , M. Merkin , A. Voronin , B. Bouquet , S. Callier , F. Dulucq , J. Fleury , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Poeschl , L. Raux , M. Ruan , N. Seguin-Moreau , F. Wicek , Z. Zhang , M. Anduze , V. Boudry , J-C. Brient , C. Clerc , G. Gaycken , C. Jauffret , A. Karar , P. Mora de Freitas , G. Musat , M. Reinhard , A. Rouge , A. L. Sanchez , J-Ch. Vanel , H. Videau , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , Yu. Arestov , A. Baird , R. N. Halsall , S. W. Nam , I. H. Park , J. Yang

A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL for International Large Detector (ILD) concept, one of the two detector concepts for the detector(s) at the future International…

Instrumentation and Detectors · Physics 2020-04-28 Adrian Irles

The CALICE Si-W electromagnetic calorimeter has been tested with electron beams (1 to 6 GeV) at DESY in May 2006, as well as electrons (6 to 45 GeV) and hadrons (6 to 80 GeV) at CERN in August and October 2006. Several millions of events…

Instrumentation and Detectors · Physics 2009-02-16 C. Carloganu , A. -M. Magnan

An innovative path for the detectors at future colliders to achieve higher performances is to use a Particle Flow approach, which requires highly granular calorimeters to image individual showers. The silicon-tungsten electromagnetic…

Instrumentation and Detectors · Physics 2026-05-01 Yukun Shi , Vincent Boudry

The CALICE collaboration has constructed highly granular electromagnetic and hadronic calorimeter prototypes to evaluate technologies for the use in detector systems at the future International Linear Collider. These calorimeters have been…

Instrumentation and Detectors · Physics 2019-08-13 Frank Simon

The technological prototype of the CALICE highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) was tested in a beam at DESY in 2017. The setup comprised seven layers of silicon sensors. Each layer comprised four sensors,…

A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm$^2$) and tungsten absorbers (each of one radiation length), has been constructed for measurement of…

Calorimeters with silicon detectors have many unique features and are proposed for several world-leading experiments. We discuss the tests of the first three 18x18 cm$^2$ layers segmented into 1024 pixels of the technological prototype of…

The CALICE prototype for a Si/W electromagnetic calorimeter has been tested in large scale test beams. Several million events with electrons and hadrons of different energies and impact angles have been recorded. The energy resolution has…

Instrumentation and Detectors · Physics 2009-02-19 Marcel Reinhard

Studies of the response of the SiD silicon-tungsten electromagnetic calorimeter (ECal) are presented. Layers of highly granular (13 mm^2 pixels) silicon detectors embedded in thin gaps (~ 1 mm) between tungsten alloy plates give the SiD…

Instrumentation and Detectors · Physics 2017-03-28 Amanda Steinhebel , James Brau

The Particle Flow Algorithms adopted for future $e^{+}e^{-}$ colliders detectors and phase-II CMS upgrade require very high granularity calorimeters to deconvolve the individual contributions of particles in jets. This is especially true…

Instrumentation and Detectors · Physics 2017-11-27 Kostiantyn Shpak

A prototype Scintillator-Tungsten electromagnetic calorimeter (ScECAL) for the ILC detector was tested in 2008 at the Fermilab test beam. Data were collected with electron, pion and muon beams in the energy range 1 to 32GeV combined with…

Instrumentation and Detectors · Physics 2010-07-16 Adil Khan

The performance of prototypes for the ALICE electromagnetic sampling calorimeter has been studied in test beam measurements at FNAL and CERN. A $4\times4$ array of final design modules showed an energy resolution of about 11%…

Instrumentation and Detectors · Physics 2012-08-27 The ALICE EMCal group

The highly granular silicon-tungsten electromagnetic calorimeter (SiW ECAL) is the reference design of the ECAL for the International Large Detector (ILD) concept, one of the two detector concepts proposed for the future International…

Instrumentation and Detectors · Physics 2020-06-24 Adrian Irles

We constructed a large-scale electromagnetic calorimeter prototype as a part of the Forward Calorimeter upgrade project (FoCal) for the ALICE experiment at the Large Hadron Collider (LHC). The prototype, also known as ``Mini FoCal'',…

An extended version of the CALICE silicon-tungsten ECAL was tested in November 2021 at the DESY beam test facility. With 15 active layers, it featured some with a thin PCB design, and a new compact DAQ system handling all layers in a common…

High Energy Physics - Experiment · Physics 2023-04-28 Vincent Boudry

A highly granular electromagnetic calorimeter prototype based on tungsten absorber and sampling units equipped with silicon pads as sensitive devices for signal collection is under construction. The full prototype will have in total 30…

Instrumentation and Detectors · Physics 2007-05-23 G. Mavromanolakis

Hybrid ECAL is a cost-conscious option of electromagnetic calorimeter (ECAL) for particle flow calorimetry to be used in a detector of International Linear Collider (ILC). It is a combination of silicon-tungsten ECAL, which realizes high…

Instrumentation and Detectors · Physics 2015-03-31 T. Suehara , H. Hirai , H. Sumida , H. Ueno , Y. Sudo , T. Yoshioka , K. Kawagoe

The first evaluation of an ultra-high granularity digital electromagnetic calorimeter prototype using 1.0-5.8 GeV/c electrons is presented. The $25\times10^6$ pixel detector consists of 24 layers of ALPIDE CMOS MAPS sensors, with a pitch of…

‹ Prev 1 2 3 10 Next ›