Related papers: Technical Design Report for PANDA Electromagnetic …
The spatial resolution of laterally segmented electromagnetic calorimeters is studied on the basis of Monte-Carlo simulations worked-out for lead fluoride material. Parametrization of the relative resolution is proposed and optimized in…
A prototype Scintillator-Tungsten electromagnetic calorimeter (ScECAL) for the ILC detector was tested in 2008 at the Fermilab test beam. Data were collected with electron, pion and muon beams in the energy range 1 to 32GeV combined with…
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high…
A calorimeter was built to measure the heat from a porous capacitive working electrode connected in a three-electrode configuration. This makes it possible to detect differences between cathodic and anodic heat production. The…
The physics programme for a coming electron linear collider is dominated by events with final states containing many jets. We develop in this paper the opinion that the best approach is to optimise the independent measurement of the tracks…
Now that ITER is under construction, interest is increasing in the specification and design of the successor machine, a Demonstration Power Plant (DEMO), which in Europe is coordinated by the EFDA Power Plant Physics and Technology…
The performance of the electromagnetic calorimeter of the HERMES experiment is described. The calorimeter consists of 840 radiation resistant F101 lead-glass counters. The response to positrons up to 27.5 GeV, the comparison between the…
This is the construction proposal for the STAR Event Plane Detector (EPD). It discusses design considerations, simulations, and physics motivations for the device. It also covers other important details such as connector construction, cost…
We present the research and development work of the first version of a 6*6 array of silicon pad detectors, carried out in India, for the proposed forward calorimeter (FOCAL) as part of the ALICE collaboration upgrade program at CERN. The…
A new design of a detector module of submillimeter thickness for an electromagnetic calorimeter is presented. It is aimed to be used in the luminometers LumiCal and BeamCal in future linear e$^{+}$e$^{-}$ collider experiments. The module…
We constructed a large-scale electromagnetic calorimeter prototype as a part of the Forward Calorimeter upgrade project (FoCal) for the ALICE experiment at the Large Hadron Collider (LHC). The prototype, also known as ``Mini FoCal'',…
The successful realization of the EIC scientific program requires the design and construction of high-performance particle detectors. Recent developments in the field of scientific computing and increased availability of high performance…
The Planck mission, designed for making measurements of the cosmic microwave background (CMB) radiation with unprecedented accuracy and angular resolution, is expected to release its first data set in the near future. For the first time in…
High precision physics at future colliders requires unprecedented highly granular calorimeters for the application of the Particle Flow (PF) algorithm. The physical proof of concept was given in the previous campaign of beam tests of physic…
The local magnetic field in a Penning-Malmberg trap is found by measuring the temperatures that result when electron plasmas are illuminated by microwaves pulses. Multiple heating resonances are observed as the pulse frequencies are swept.…
This paper considers Electromagnetic Compatibility (EMC) aspects in the context of Power Line Communication (PLC) systems. It offers a complete overview of both narrow band PLC and broad band PLC EMC norms. How to interpret and translate…
A special beam line for high energy electron radiography is designed, including achromat and imaging systems. The requirement of the angle and position correction on the target from imaging system can be approximately realized by fine…
The H1 detector at HERA has been upgraded by the addition of a new electromagnetic calorimeter. This is installed in the HERA tunnel close to the electron beam line at a position 8m from the interaction point in the electron beam direction.…
Constant potential methods (CPM) enable computationally efficient simulations of the solid-liquid interface at conducting electrodes in molecular dynamics (MD). They have been successfully used, for example, to realistically model the…
We introduce the polymer analysis and discovery array (PANDA), an automated system for high-throughput electrodeposition and functional characterization of polymer films. The PANDA is a custom, modular, and low-cost system based on a CNC…