An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed…

Instrumentation and Detectors · Physics 2023-07-05 CUPID , CROSS collaborations , : , K. Alfonso , A. Armatol , C. Augier , F. T. Avignone , O. Azzolini , M. Balata , I. C. Bandac , A. S. Barabash , G. Bari , A. Barresi , D. Baudin , F. Bellini , G. Benato , V. Berest , M. Beretta , M. Bettelli , M. Biassoni , J. Billard , V. Boldrini , A. Branca , C. Brofferio , C. Bucci , J. M. Calvo-Mozota , J. Camilleri , A. Campani , C. Capelli , S. Capelli , L. Cappelli , L. Cardani , P. Carniti , N. Casali , E. Celi , C. Chang , D. Chiesa , M. Clemenza , I. Colantoni , S. Copello , E. Craft , O. Cremonesi , R. J. Creswick , A. Cruciani , A. D'Addabbo , G. D'Imperio , S. Dabagov , I. Dafinei , F. A. Danevich , M. De Jesus , P. de Marcillac , S. Dell'Oro , S. Di Domizio , S. Di Lorenzo , T. Dixon , V. Dompé , A. Drobizhev , L. Dumoulin , G. Fantini , M. Faverzani , E. Ferri , F. Ferri , F. Ferroni , E. Figueroa-Feliciano , L. Foggetta , J. Formaggio , A. Franceschi , C. Fu , S. Fu , B. K. Fujikawa , A. Gallas , J. Gascon , S. Ghislandi , A. Giachero , A. Gianvecchio , M. Girola , L. Gironi , A. Giuliani , P. Gorla , C. Gotti , C. Grant , P. Gras , P. V. Guillaumon , T. D. Gutierrez , K. Han , E. V. Hansen , K. M. Heeger , D. L. Helis , H. Z. Huang , A. Ianni , L. Imbert , J. Johnston , A. Juillard , G. Karapetrov , G. Keppel , H. Khalife , V. V. Kobychev , Yu. G. Kolomensky , S. I. Konovalov , R. Kowalski , T. Langford , M. Lefevre , R. Liu , Y. Liu , P. Loaiza , L. Ma , M. Madhukuttan , F. Mancarella , C. A. Marrache-Kikuchi , L. Marini , S. Marnieros , M. Martinez , R. H. Maruyama , Ph. Mas , D. Mayer , G. Mazzitelli , Y. Mei , S. Milana , S. Morganti , T. Napolitano , M. Nastasi , J. Nikkel , S. Nisi , C. Nones , E. B. Norman , V. Novosad , I. Nutini , T. O'Donnell , E. Olivieri , M. Olmi , J. L. Ouellet , S. Pagan , C. Pagliarone , L. Pagnanini , L. Pattavina , M. Pavan , H. Peng , G. Pessina , V. Pettinacci , C. Pira , S. Pirro , D. V. Poda , O. G. Polischuk , I. Ponce , S. Pozzi , E. Previtali , A. Puiu , S. Quitadamo , A. Ressa , R. Rizzoli , C. Rosenfeld , P. Rosier , J. A. Scarpaci , B. Schmidt , V. Sharma , V. N. Shlegel , V. Singh , M. Sisti , P. Slocum , D. Speller , P. T. Surukuchi , L. Taffarello , C. Tomei , J. A. Torres , V. I. Tretyak , A. Tsymbaliuk , M. Velazquez , K. J. Vetter , S. L. Wagaarachchi , G. Wang , L. Wang , R. Wang , B. Welliver , J. Wilson , K. Wilson , L. A. Winslow , M. Xue , L. Yan , J. Yang , V. Yefremenko , V. I. Umatov , M. M. Zarytskyy , J. Zhang , A. Zolotarova , S. Zucchelli

The use of High Purity Germanium detectors operated in ionization mode at cryogenic temperatures is investigated as an external background mitigation solution for bolometers used in rare-event search experiments. A simple experimental setup…

High Energy Physics - Experiment · Physics 2025-09-05 Chloé Goupy , Stefanos Marnieros , Beatrice Mauri , Claudia Nones , Matthieu Vivier

Energy resolution, alpha/beta ratio, and the pulse shape discrimination ability of the ZnWO_4 crystal scintillators were studied. The radioactive contamination of a ZnWO_4 crystal was investigated in the Solotvina Underground Laboratory.…

Compelling experimental evidences of neutrino oscillations and their implication that neutrinos are massive particles have given neutrinoless double beta decay a central role in astroparticle physics. In fact, the discovery of this elusive…

Instrumentation and Detectors · Physics 2015-06-22 Valter Bonvicini , Silvia Capelli , Oliviero Cremonesi , Giacomo Cucciati , Luca Gironi , Maura Pavan , Ezio Previtali , Monica Sisti

The study of neutrinoless double beta decay has attracted much attention as it can provide valuable information about the mass and the nature of the neutrino. The double beta decay (DBD) itself is also of interest in nuclear physics. While…

Instrumentation and Detectors · Physics 2021-11-18 Swati Thakur , A. Mazumdar , R. Shah , V. Vatsa , V. Nanal , M. S. Pose , Pushpendra P. Singh , P. K. Raina , R. G. Pillay

Scintillating, cryogenic bolometers are widely used in the field of rare event searches. Their main advantages are an excellent energy resolution and particle identification on an event-by-event basis. The sensitivity of experiments…

Molybdenum based crystals such as Li$_2$MoO$_4$ and CaMoO$_4$ are emerging as leading candidates for next generation experiments searching for neutrino-less double beta decay with cryogenic calorimeters (CUPID, AMoRE). The exquisite energy…

Instrumentation and Detectors · Physics 2019-08-30 N. Casali , L. Cardani , I. Colantoni , A. Cruciani , S. Di Domizio , M. Martinez , G. Pettinari , M. Vignati

Scintillator detectors can be used in experiments searching for neutrinoless double beta decay. A wide variety of double beta decay candidate isotopes can be made into scintillators or can be loaded into scintillators. Experimental programs…

Instrumentation and Detectors · Physics 2008-12-18 Mark C. Chen

A scintillating bolometer technology based on $^{100}$Mo-enriched lithium molybdate (Li$_2$$^{100}$MoO$_4$) crystals has been developed by LUMINEU to search for neutrinoless double-beta ($0\nu 2\beta$) decay of $^{100}$Mo. The results of…

Instrumentation and Detectors · Physics 2017-11-06 D. V. Poda

The large statistics collected during the operation of a ZnMoO$_4$ array, for a total exposure of 1.3 kg $\cdot$ day of $^{100}$Mo, allowed the first bolometric observation of the two neutrino double beta decay of $^{100}$Mo. The observed…

The CUPID-Mo experiment is searching for neutrinoless double beta decay in $^{100}$Mo, evaluating the technology of cryogenic scintillating Li$_{2}^{100}$MoO$_4$ detectors for CUPID (CUORE Upgrade with Particle ID). CUPID-Mo detectors…

The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected…

The unique features (super-low background and large sensitive volume) of the CTF and BOREXINO set ups are used in the CAMEO project for a high sensitivity study of 100-Mo and 116-Cd neutrinoless double beta decay. Pilot measurements with…

Germanium detectors have very good capabilities for the investigation of rare phenomena like the neutrinoless double beta decay. Rejection of the background entangling the expected signal is one primary goal in this kind of experiments.…

Nuclear Experiment · Physics 2008-11-26 H. Gómez , S. Cebrián , J. Morales , J. A. Villar

A wide range of scintillating bolometers is under investigation for applications in the search for rare events and processes beyond the Standard Model. In this work, we report the first measurement of a natural, non-molybdenum-doped,…

Bolometric detectors are excellent devices for the investigation of neutrinoless double-beta decay (0$\nu\beta\beta$). The observation of such decay would demonstrate the violation of lepton number, and at the same time it would necessarily…

We have developed and tested a new way of coupling bolometric light detectors to scintillating crystal bolometers based upon simply resting the light detector on the crystal surface, held in position only by gravity. This straightforward…

Instrumentation and Detectors · Physics 2019-05-30 M. Barucci , J. W. Beeman , V. Caracciolo , L. Pagnanini , L. Pattavina , G. Pessina , S. Pirro , C. Rusconi , K. Schäffner

CUPID-Mo is a bolometric experiment to search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{100}$Mo. In this article, we detail the CUPID-Mo detector concept, assembly, installation in the underground laboratory in Modane in…