English
Related papers

Related papers: CdWO4 bolometers for Double Beta Decay search

200 papers

Bolometers are ideal devices in the search for neutrinoless Double Beta Decay. Enlarging the mass of individual detectors would simplify the construction of a large experiment, but would also decrease the background per unit mass induced by…

Nuclear Experiment · Physics 2015-01-27 L. Cardani , L. Gironi , J. W. Beeman , I. Dafinei , Z. Ge , G. Pessina , S. Pirro , Y. Zhu

A 891 g BGO scintillating bolometer has been tested at 10 mK in the underground Laboratori Nazionali del Gran Sasso (Italy). The discrimination capability, the radio-purity of the compound and the main features of the crystal have been…

Nuclear Experiment · Physics 2012-08-28 Laura Cardani , Sergio Di Domizio , Luca Gironi

Bolometers have proven to be good detectors for the search of neutrinoless double beta decay. By operating at cryogenic temperatures, they feature excellent energy resolution and low background. The detection of the possible light emitted…

Data Analysis, Statistics and Probability · Physics 2011-10-10 G. Piperno , S. Pirro , M. Vignati

Energy resolution, alpha/beta ratio, pulse-shape discrimination for gamma rays and alpha particles, temperature dependence of scintillation properties, and radioactive contamination were studied with CaMoO4 crystal scintillators. A high…

The sensitivity of neutrinoless double beta (0n2b) decay experiments is mainly depended on the internal background of a detector which, in its turn, is defined by the purity of material and possibility for selection of background events.…

Instrumentation and Detectors · Physics 2013-04-17 Nikita Khanbekov , Vladimir Alenkov , Aleksander Burenkov , Oleg Buzanov , HongJoo Kim , Vasily Kornoukhov , JungHo So

The CROSS experiment will search for neutrinoless double-beta decay using a specific mechanical structure to hold thermal detectors. The design of the structure was tuned to minimize the background contribution, keeping an optimal detector…

The thesis describes the experimental setup designed to study the decay spectrum of 106Cd, a candidate for positive double-$\beta$ decay and the Monte Carlo simulation used to estimate the background expected in 1 year of measurements.

High Energy Physics - Experiment · Physics 2025-01-13 Ester Ricci

Possibilities to search for double beta decay of alpha/beta unstable nuclei, many of which have higher energy release than "conventional" (beta stable) double beta decay candidates, are discussed. First experimental half-life limits on…

Nuclear Experiment · Physics 2009-11-10 V. I. Tretyak , F. A. Danevich , S. S. Nagorny , Yu. G. Zdesenko

We report the development of a CaMoO4 crystal low temperature detector for the AMoRE neutrinoless double beta decay (0{\nu}\b{eta}\b{eta}) search experiment. The prototype detector cell was composed of a 216 g CaMoO4 crystal and a metallic…

We report results of an experiment conducted in May 1997 to measure CdZnTe background and background reduction schemes in space flight conditions similar to those of proposed hard X-ray astrophysics missions. A 1 cm^2 CdZnTe detector was…

Astrophysics · Physics 2007-05-23 P. Bloser , J. Grindlay , T. Narita , F. Harrison

The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of $^{82}$Se neutrinoless double-beta decay (0$\nu\beta\beta$).…

ZnSe scintillating bolometers are good candidates for future Double Beta Decay searches, because of the 82Se high Q-value and thanks to the possibility of alpha background rejection on the basis of the scintillation signal. In this paper we…

Nuclear Experiment · Physics 2011-05-23 C. Arnaboldi , S. Capelli , O. Cremonesi , L. Gironi , M. Pavan , G. Pessina , S. Pirro

The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario.…

Instrumentation and Detectors · Physics 2020-11-30 A. Armatol , E. Armengaud , W. Armstrong , C. Augier , F. T. Avignone , O. Azzolini , A. Barabash , G. Bari , A. Barresi , D. Baudin , F. Bellini , G. Benato , M. Beretta , L. Bergè , M. Biassoni , J. Billard , V. Boldrini , A. Branca , C. Brofferio , C. Bucci , J. Camilleri , S. Capelli , L. Cappelli , L. Cardani , P. Carniti , N. Casali , A. Cazes , E. Celi , C. Chang , M. Chapellier , A. Charrier , D. Chiesa , M. Clemenza , I. Colantoni , F. Collamati , S. Copello , F. Cova , O. Cremonesi , R. J. Creswick , A. Cruciani , A. D'Addabbo , G. D'Imperio , I. Dafinei , F. A. Danevich , M. de Combarieu , M. De Jesus , P. de Marcillac , S. Dell'Oro , S. Di Domizio , V. Dompé , A. Drobizhev , L. Dumoulin , G. Fantini , M. Fasoli , M. Faverzani , E. Ferri , F. Ferri , F. Ferroni , E. Figueroa-Feliciano , J. Formaggio , A. Franceschi , C. Fu , S. Fu , B. K. Fujikawa , J. Gascon , A. Giachero , L. Gironi , A. Giuliani , P. Gorla , C. Gotti , P. Gras , M. Gros , T. D. Gutierrez , K. Han , E. V. Hansen , K. M. Heeger , D. L. Helis , H. Z. Huang , R. G. Huang , L. Imbert , J. Johnston , A. Juillard , G. Karapetrov , G. Keppel , H. Khalife , V. V. Kobychev , Yu. G. Kolomensky , S. Konovalov , Y. Liu , P. Loaiza , L. Ma , M. Madhukuttan , F. Mancarella , R. Mariam , L. Marini , S. Marnieros , M. Martinez , R. H. Maruyama , B. Mauri , D. Mayer , Y. Mei , S. Milana , D. Misiak , T. Napolitano , M. Nastasi , X. F. Navick , J. Nikkel , R. Nipoti , S. Nisi , C. Nones , E. B. Norman , V. Novosad , I. Nutini , T. O'Donnell , E. Olivieri , C. Oriol , J. L. Ouellet , S. Pagan , C. Pagliarone , L. Pagnanini , P. Pari , L. Pattavina , B. Paul , M. Pavan , H. Peng , G. Pessina , V. Pettinacci , C. Pira , S. Pirro , D. V. Poda , T. Polakovic , O. G. Polischuk , S. Pozzi , E. Previtali , A. Puiu , A. Ressa , R. Rizzoli , C. Rosenfeld , C. Rusconi , V. Sanglard , J. A. Scarpaci , B. Schmidt , V. Sharma , V. Shlegel , V. Singh , M. Sisti , D. Speller , P. T. Surukuchi , L. Taffarello , O. Tellier , C. Tomei , V. I. Tretyak , A. Tsymbaliuk , A. Vedda , M. Velazquez , K. J. Vetter , S. L. Wagaarachchi , G. Wang , L. Wang , B. Welliver , J. Wilson , K. Wilson , L. A. Winslow , M. Xue , L. Yan , J. Yang , V. Yefremenko , V. Yumatov , M. M. Zarytskyy , J. Zhang , A. Zolotarova , S. Zucchelli

BINGO is a project aiming to set the grounds for large-scale bolometric neutrinoless double-beta-decay experiments capable of investigating the effective Majorana neutrino mass at a few meV level. It focuses on developing innovative…

Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low…

The Aurora experiment to investigate double beta decay of $^{116}$Cd with the help of 1.162 kg cadmium tungstate crystal scintillators enriched in $^{116}$Cd to 82\% is in progress at the Gran Sasso Underground Laboratory. The half-life of…

A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The…

Instrumentation and Detectors · Physics 2021-03-24 The CUPID Interest Group , A. Armatol , E. Armengaud , W. Armstrong , C. Augier , F. T. Avignone , O. Azzolini , I. C. Bandac , A. S. Barabash , G. Bari , A. Barresi , D. Baudin , F. Bellini , G. Benato , M. Beretta , L. Bergé , Ch. Bourgeois , M. Biassoni , J. Billard , V. Boldrini , A. Branca , C. Brofferio , C. Bucci , J. M. Calvo-Mozota , J. Camilleri , A. Candela , S. Capelli , L. Cappelli , L. Cardani , P. Carniti , N. Casali , A. Cazes , E. Celi , C. Chang , M. Chapellier , A. Charrier , D. Chiesa , M. Clemenza , I. Colantoni , F. Collamati , S. Copello , F. Cova , O. Cremonesi , R. J. Creswick , A. Cruciani , A. D'Addabbo , G. D'Imperio , I. Dafinei , F. A. Danevich , M. de Combarieu , M. De Deo , M. De Jesus , P. de Marcillac , S. Dell'Oro , S. Di Domizio , V. Dompe , A. Drobizhev , L. Dumoulin , G. Fantini , M. Fasoli , M. Faverzani , E. Ferri , F. Ferri , F. Ferroni , E. Figueroa-Feliciano , J. Formaggio , A. Franceschi , C. Fu , S. Fu , B. K. Fujikawa , J. Gascon , A. Giachero , L. Gironi , A. Giuliani , P. Gorla , C. Gotti , P. Gras , M. Gros , E. Guerard , T. D. Gutierrez , K. Han , E. V. Hansen , K. M. Heeger , D. L. Helis , H. Z. Huang , R. G. Huang , A. Ianni , L. Imbert , J. Johnston , A. Juillard , G. Karapetrov , G. Keppel , H. Khalife , V. V. Kobychev , Yu. G. Kolomensky , S. I. Konovalov , Y. Liu , P. Loaiza , L. Ma , M. Madhukuttan , F. Mancarella , R. Mariam , L. Marini , S. Marnieros , M. Martinez , R. H. Maruyama , B. Mauri , D. Mayer , Y. Mei , S. Milana , D. Misiak , T. Napolitano , M. Nastasi , X. -F. Navick , J. Nikkel , R. Nipoti , S. Nisi , C. Nones , E. B. Norman , V. Novosad , I. Nutini , T. O'Donnell , G. Olivier , E. Olivieri , C. Oriol , J. L. Ouellet , S. Pagan , C. Pagliarone , L. Pagnanini , P. Pari , L. Pattavina , B. Paul , M. Pavan , H. Peng , G. Pessina , V. Pettinacci , C. Pira , S. Pirro , D. V. Poda , T. Polakovic , O. G. Polischuk , S. Pozzi , E. Previtali , A. Puiu , A. Ressa , D. Reynet , R. Rizzoli , C. Rosenfeld , V. Sanglard , J. A. Scarpaci , B. Schmidt , V. Sharma , V. N. Shlegel , V. Singh , M. Sisti , D. Speller , P. T. Surukuchi , L. Taffarello , O. Tellier , C. Tomei , V. I. Tretyak , A. Tsymbaliuk , A. Vedda , M. Velazquez , K. J. Vetter , S. L. Wagaarachchi , G. Wang , L. Wang , B. Welliver , J. Wilson , K. Wilson , L. A. Winslow , M. Xue , L. Yan , J. Yang , V. Yefremenko , V. I. Yumatov , M. M. Zarytskyy , J. Zhang , A. S. Zolotarova , S. Zucchelli

A new R&D on lithium molybdate scintillators has begun within a project CLYMENE (Czochralski growth of Li$_2$MoO$_4$ crYstals for the scintillating boloMeters used in the rare EveNts sEarches). One of the main goals of the CLYMENE is a…

A radiopure cadmium tungstate crystal scintillator, enriched in 106-Cd to 66%, with mass of 216 g (106-CdWO4) was used in coincidence with four ultra-low background HPGe detectors contained in a single cryostat to search for double beta…

Double beta processes in 64-Zn, 70-Zn, 180-W, and 186-W have been searched for with the help of large volume (0.1-0.7 kg) low background ZnWO4 crystal scintillators at the Gran Sasso National Laboratories of the INFN. Total time of…