Related papers: Radiation Damage Studies of Silicon Photomultiplie…
Silicon photomultipliers (SiPMs) are currently the most prevalent photon detection technology in modern experiments in high-energy physics, astroparticle physics, neutrino physics, and dark matter searches. The high detection efficiency for…
Dark count rate and correlated noise rate are among the main parameters that characterize silicon photomultipliers (SiPM). Typically, these parameters are evaluated by applying approximate formulas, or by fitting specific models, to the…
Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless {\beta}{\beta} decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of…
Silicon photomultipliers are photon sensors based on an array of pixels, each consisting of a single photon avalanche photodiode (SPAD). Reading of the array is not done on a single-pixel basis, but all pixels are read simultaneously.…
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area…
We characterized the S13360-3050CS Multi-Pixel Photon Counter (MPPC), a silicon photomultiplier (SiPM) manufactured by Hamamatsu Photonics K.K.. Measurements were obtained inside a light tight dark box using 365 nm, 400 nm, 525 nm, 660 nm,…
Silicon photomultipliers (SiPMs) are prone to radiation damage which causes an increase of dark count rate. This leads to an increase in low-energy threshold in a gamma-ray detector combining SiPM and a scintillator. Despite this drawback,…
It is of great importance to develop a photodetector system with an ultralow radioactivity background in rare event searches. Silicon photomultipliers (SiPMs) and application-specific integrated circuits (ASICs) are two ideal candidates for…
A dedicated single-cell SiPM structure is designed and measured to investigate the radiation damage effects on the gain and breakdown voltage of SiPMs exposed to a reactor neutron fluence up to $\Phi$ = 5e13 cm$^{-2}$. The cell has a pitch…
We present a 'digital SiPM' photo-detection chip combining single photon sensitive avalanche photo diodes and CMOS readout electronics on a single die. The chip has a size of $8046\times9032\,\mu m^2$ with $72.5\%$ of photo sensitive area.…
A novel concept to enhance the photo-detection efficiency (PDE) of silicon photomultipliers (SiPMs) has been applied and remarkable positive results can be reported. This concept uses arrays of microlenses to cover every second SiPM pixel…
Large-area silicon photomultipliers (SiPMs) are desired in many applications where large surfaces have to be covered. For instance, a large area SiPM has been developed by Hamamatsu Photonics in collaboration with the University of Geneva,…
We present the design of an automated current-voltage (IV) multiplexer (MUX) that enables accurate measurement of the dark current in cryogenic silicon photomultipliers (SiPMs), achieving a sensitivity equivalent to detecting less than one…
Pixel detectors are used in the innermost part of the multi purpose experiments at LHC and are therefore exposed to the highest fluences of ionising radiation, which in this part of the detectors consists mainly of charged pions. The…
Photo-multiplier tubes (PMTs) and silicon photo-multipliers (SiPMs) are detectors sensitive to single photons that are widely used for the detection of scintillation and Cerenkov light in subatomic physics and medical imaging. This paper…
The advent of silicon photomultipliers has enabled big advances in high energy physics instrumentation, for example by allowing the construction of extremely granular hadronic calorimeters with photon sensors integrated into small…
Many characteristics of Silicon Photomultipliers can be tuned with temperature and operation voltage. We present preliminary results of a study of the effect of these two operation parameters on the time resolution of large active area…
A novel modular high-resolution charged-particle tracking detector design using $250\mu m$ diameter, round, scintillating fibers and SiPM arrays for readout is presented. The fiber modules consist of 8 layers of 128 fibers, mechanically sta…
Next generation multi-ton scale noble liquid experiments have the unique opportunity to discover dark matter particles at the TeV scale, reaching the sensitivity of 10^-48 cm2 in the WIMP nucleon scattering cross-section. A prerequisite…
A combination of scintillator, wavelength shifting (WLS) fiber, and silicon photomultiplier (SiPM) shows an excellent performance in the `$K_{L}$ and $\mu$ detector (KLM)' of the Belle II experiment. In this study, we present the R&D…