Related papers: Digital pulse-shape discrimination of fast neutron…
In this contribution we report on further investigations of the recently-evaluated Constant-Fraction Time-over-Threshold (CF-ToT) method for neutron/gamma-ray pulse shape discrimination (PSD). The superiority of the CF-ToT PSD method over…
Liquid-argon scintillation detectors are used in fundamental physics experiments and are being considered for security applications. Previous studies have suggested that the addition of small amounts of xenon dopant improves performance in…
Pulse shape discrimination (PSD) is one of the most distinctive features of liquid scintillators. Since the introduction of the scintillation techniques in the field of particle detection, many studies have been carried out to characterize…
In particle physics experiments, pulse shape discrimination (PSD) is a powerful tool for eliminating the major background from signals. However, the analysis methods have been a bottleneck to improving PSD performance. In this study, two…
Nuclear recoil measurements with high-purity Germanium detectors are very promising to directly detect dark matter candidates. The main background sources in such experiments are natural radioactivity and microphonic noise. Digital pulse…
Pulse Shape Discrimination (PSD) is a widely used technique in many experimental analysis. In this study, we specifically aimed to assess the effectiveness of PSD in accurately measuring decay time. We measured the decay times of a 0.1 wt%…
Frequency gradient analysis (FGA) effectively discriminates neutrons and gamma rays by examining the frequency-domain features of the photomultiplier tube anode signal. This approach is insensitive to noise but is inevitably affected by the…
Possibilities of discriminating neutrons and gamma rays in the AGATA gamma-ray tracking spectrometer have been investigated with the aim of reducing the background due to inelastic scattering of neutrons in the high-purity germanium…
Timing systems based on Analog-to-Digital Converters are widely used in the design of previous high energy physics detectors. In this paper, we propose a new method based on deep learning to extract the time information from a finite set of…
The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is…
Ultra-high dose rate electron sources require dose rate independent dosimeters and a calibrated dose control system for accurate delivery. In this study, we developed a single-pulse dose monitoring and a real-time dose-based control system…
We present a method for detecting neutrons using scintillating lithium gadolinium borate crystal shards in a plastic matrix while maintaining high gamma rejection. We have procured two cylindrical detectors, 5"\times5", containing 1%…
Background: Scintillation dosimetry has promising qualities for ultra-high dose rate (UHDR) radiotherapy (RT), but no system has shown compatibility with mean dose rates ($\bar{DR}$) above 100 Gy/s and doses per pulse ($D_p$) exceeding 1.5…
The light output, $\alpha/\beta$ ratio, and pulse shape have been investigated at $-25^\circ$ C with PbWO$_4$ crystal scintillators undoped, and doped by F, Eu, Mo, Gd and S. The fast $0.01-0.06 \mu$s and middle $0.1-0.5 \mu$s components of…
The recent development of Water-based Liquid Scintillator (WbLS), and the concurrent development of high-efficiency and high-precision-timing light sensors, has opened up the possibility for a new kind of large-scale detector capable of a…
Waveform sampling systems are used pervasively in the design of front end electronics for radiation detection. The introduction of new feature extraction algorithms (eg. neural networks) to waveform sampling has the great potential to…
We report on the construction and upgrade of a Lawrence Berkeley National Laboratory Cosmic Muons Detector. We modify the electronics and mechanics to achieve a highly efficient gamma-ray and cosmic-ray detector. Each detector module uses a…
A 3-D position sensitive neutron detector is being developed based on a plastic scintillator array. A double side SiPM readout is used to determine the depth of interaction (DOI) in each scintillator unit. In the preliminary test, the DOI…
Gamma rays and neutrons, emitted following spontaneous fission of 252Cf, were measured in an AGATA experiment performed at INFN Laboratori Nazionali di Legnaro in Italy. The setup consisted of four AGATA triple cluster detectors (12 36-fold…
A wideband phase comparator for precise measurements of phase difference of high current shunts has been developed at INRIM. The two-input digital phase detector is realized with a precision wideband digitizer connected through a pair of…