Related papers: Digital pulse-shape discrimination of fast neutron…
Flash Analog to Digital Convertor (FADC) is frequently used in nuclear and particle physics experiments, often as the major component in big multi-channel systems. The large data volume makes the optimization of operating parameters…
Measurement time represents a critical bottleneck limiting the operational speed of neutral atom quantum computers, as it cannot be accelerated through parallelization like other quantum operations. We present a protocol for fast…
Two detectors for energy-resolved fast-neutron imaging in pulsed broad-energy neutron beams are presented. The first one is a neutron-counting detector based on a solid neutron converter coupled to a gaseous electron multiplier (GEM). The…
Purpose: A diode EDGE Detector with a newly designed electrometer has been characterized for use in an UHDR electron beam and demonstrated appropriateness for UHDR FLASH radiotherapy dosimetry. Methods: Dose linearity, mean dose rate, and…
The development of large-area homogeneous photo-detectors with sub-millimeter path lengths for direct Cherenkov light and for secondary-electrons opens the possibility of large time-of-flight systems for relativistic particles with…
The 499 pixel photomultiplier cameras of the VERITAS gamma ray telescopes are instrumented with 500MHz sampling Flash ADCs. This paper describes a preliminary investigation of the best methods by which to exploit this information so as to…
To study the dependence of the equation of state of high density nuclear matter on the term characterizing the isospin (proton-neutron) asymmetry of nuclear matter, it is necessary to measure azimuthal flow of neutrons as well as azimuthal…
Scintillator doped with a high neutron-capture cross-section material can be used to detect neutrons via their resulting gamma rays. Examples of such detectors using liquid scintillator have been successfully used in high-energy physics…
We present a new conceptual radiation detector, the Architected Multimaterial Scintillator System, that utilizes a scintillator composed of multiple materials arranged in architected structures to enable new capabilities. By structuring…
We extend balloon and sample-smoothing estimators, two types of variable-bandwidth kernel density estimators, by a shift parameter and derive their asymptotic properties. Our approach facilitates the unified study of a wide range of density…
We show data from a new type of detector that can be used to determine neutron flux, energy distribution, and direction of neutron motion for both fast and thermal neutrons. Many neutron detectors are plagued by large backgrounds from…
DD and DT reaction rates may be compared to determine plasma temperatures in the 10--200 eV range. Distinguishing neutrons from these two reactions is difficult when yields are low or unpredictable. Time of flight methods fail if the source…
This paper describes the data acquisition system used for data readout from a segmented detector of reactor antineutrinos with active shielding. Theoretical approach to the data acquisition is described and two possible solutions using QDCs…
We demonstrate a high data-rate light-pulse atom interferometer for measuring acceleration. The device is optimized to operate at rates between 50 Hz to 330 Hz with sensitivities of 0.57 {\mu}g/rtHz to 36.7 {\mu}g/rtHz, respectively. Our…
Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional…
In the work presented here we built and evaluated a single-channel neutron detection unit consisting of a ZnS:$^6$LiF scintillator with embedded WLS fibers readout by a SiPM. The unit has a sensitive volume of 2.4 x 2.8 x 50 mm$^3$; 12 WLS…
Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…
A construction of a thermal neutron testing detector with a thin [ZnS(Ag)+$^6$LiF] scintillator is described. Results of an investigation of sources of the detector pulse origin and the pulse features in a ground and underground conditions…
One of our two methods for fast-neutron imaging with spectrometric capability is presented here. It is a neutron-counting technique based on a hydrogenous neutron converter coupled to Gaseous Electron Multipliers (GEM). The principles of…
We present the timing characteristics of the flash ADC readout of the GlueX forward calorimeter, which depends on precise measurement of arrival time of pulses from FEU 84-3 photomultiplier tubes to suppress backgrounds. The tests presented…