Related papers: A Simple Method for Rise-Time Discrimination of Sl…
Semiconductor double quantum dots (DQD) coupled to superconducting microwave resonators offer a promising platform for the detection of single microwave photons. In previous works, the photodetection was studied for a monochromatic source…
This paper describes the design and testing results of an 8 channels preamplifier-discriminator circuit based on a resistive feedback Transimpedance Amplifier architecture and a Leading-Edge Discriminator stage for fast high-accuracy time…
The characterization of individual nanoparticles in a liquid constitutes a critical challenge for environmental, material, and biological sciences. To detect nanoparticles, electronic approaches are especially desirable owing to their…
In typical nuclear physics experiments with radioactive ion beams (RIBs) selected by the in-flight separation technique, Si detectors or ionization chambers are usually equipped for the charge determination of RIBs. The obtained charge…
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with…
We employ ultra-broadband terahertz-midinfrared probe pulses to characterize the optical response of photoinduced charge-carrier plasmas in high-resistivity silicon in a reflection geometry, over a wide range of excitation densities…
The LaBr3:Ce scintillator has been widely studied for nuclear spectroscopy because of its optimal energy resolution (<3%@ 662 keV) and time resolution (~300 ps). Despite these promising properties, the intrinsic radiation background of…
The temporal response of single-photon detectors is usually obtained by measuring their impulse response to short-pulsed laser sources. In this work, we present an alternative approach using time-correlated photon pairs generated in…
A novel characterization method to measure the pulse duration of ultrafast near-IR pulses is introduced, which uses simple tabletop optics, is relatively inexpensive, and is expected to work in a broad wavelength range. Our diagnostic tool…
Nanosecond pulsed barrier discharges in atmospheric pressure argon are simulated using spatially one- and two-dimensional fluid-Poisson models using the reaction kinetics model presented by Stankov et al. [1], which considers all ten argon…
Using a single-phase liquid argon detector with a signal yield of 4.85 photoelectrons per keV of electronic-equivalent recoil energy (keVee), we measure the scintillation time dependence of both electronic and nuclear recoils in liquid…
We demonstrate a high data-rate light-pulse atom interferometer for measuring acceleration. The device is optimized to operate at rates between 50 Hz to 330 Hz with sensitivities of 0.57 {\mu}g/rtHz to 36.7 {\mu}g/rtHz, respectively. Our…
Particle identification using the energy loss in silicon detectors is a powerful technique for probing the Standard Model (SM) as well as searching for new particles beyond the SM. Traditionally, such techniques use the truncated mean of…
Optimal detection of ultra wideband (UWB) pulses in a UWB transceiver employing multiple detector types is proposed and analyzed in this paper. We propose several fusion techniques for fusing decisions made by individual IR-UWB detectors.…
Radio pulses from pulsars are affected by plasma dispersion, which results in a frequency-dependent propagation delay. Variations in the magnitude of this effect lead to an additional source of red noise in pulsar timing experiments,…
This paper presents a novel pulse-reconstruction method well suited to sparsely sampled repetitive data, such as commonly arise from trains of ultrashort laser-pulses. Typically waveforms in such traces are fully instrument-limited by the…
A successfull application of Geiger-mode multipixel avalanche diodes (GMAPDs) for pulse-shape discrimination in alpha-beta spectrometry using organic liquid scintillator is described in this paper. Efficient discrimination of alpha and beta…
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which…
This paper presents the principles of operation of Resistive AC-Coupled Silicon Detectors (RSDs) and measurements of the temporal and spatial resolutions using a combined analysis of laser and beam test data. RSDs are a new type of n-in-p…
Slow data acquisition in terahertz time-domain spectroscopy (THz-TDS) has hindered the technique's ability to resolve "fast" dynamics occurring on the microsecond timescale. This timescale, arguably too slow to be accessed via standard…