Related papers: High resolution optical time domain reflectometer …
A fast silicon-graphene hybrid plasmonic waveguide photodetectors beyond 1.55 {\mu}m is proposed and realized by introducing an ultra-thin wide silicon-on-insulator ridge core region with a narrow metal cap. With this novel design, the…
The recent introduction of coherent optical communications has created a compelling need for ultra-fast phase-sensitive measurement techniques operating at milliwatt peak power levels and in time scales ranging from sub-picoseconds to…
Two large-area, low noise, high speed fluorescence detectors have been built. One detector consists of a photodiode with an area of 28 mm x 28 mm and a low noise transimpedance amplifier. This detector has a input light-equivalent spectral…
High-luminosity particle collider experiments such as the ones planned at the High-Luminosity Large Hadron Collider require ever-greater vertexing precision of the tracking detectors, necessitating also reductions in the material budget of…
In organic photodiodes (OPDs) light is absorbed by excitons, which dissociate to generate photocurrent. Here, we demonstrate a novel type of OPD in which light is absorbed by polaritons, hybrid light-matter states. We demonstrate polariton…
Millimetre-wave observations represent an important tool for Cosmology studies. The Line Intensity Mapping (LIM) technique has been proposed to map in three dimensions the specific intensity due to line (e.g. [CII], CO) emission, for…
High resolution (900 Hz full-width at half maximum) frequency domain spectroscopy near 0.2Terahertz is achieved using an exact frequency spacing comb-source in the optical communications band, filtering and photo-mixing in a custom…
Optical transition radiation interferometry (OTRI) has been shown to be a very useful technique to measure the divergence of electron beams with energies in the range of 15-100 MeV. However, application of this method to low energy or very…
We demonstrate up-conversion single-photon detectors based on integrated periodically poled lithium niobate waveguides, which incorporate two mode filters and a directional coupler. The two mode filters are optimized for the fiber-waveguide…
The orbital angular momentum (OAM) of light provides an unbounded set of orthogonal modes for ultrahigh-capacity optical information processing. However, current OAM detection schemes typically rely on light interference or diffraction,…
Flying particle sensors in hollow-core photonic crystal fibers require accurate localization of the optically trapped microparticles. We report position measurement to micrometer-resolution, using optical frequency domain reflectometry, of…
An innovative optical module (OM) with segmented light-sensitive area has been developed for IceCube-Gen2 that will take neutrino astronomy at the South Pole to the next level. It builds on the successful features of the mDOM and D-Egg…
Organic photodetectors (OPDs) possess bright prospects in applications of medical imaging and wearable electronics due to the advantages such as low cost, good biocompatibility, and good flexibility. Photomultiplication OPDs (PM-OPDs)…
To achieve a distributed reflectivity measurement along an optical fiber, we develop a simplified cost-effective configuration of optical correlation- (or coherence-) domain reflectometry based on a synthesized optical coherence function by…
This study discusses key characteristics and limitations of time-domain reflectometry (TDR) systems based on the Hermitian symmetric orthogonal frequency-division multiplexing (HS-OFDM) scheme for power line sensing. In this sense, a system…
Coherent diffractive imaging is unique as the only route for achieving diffraction-limited spatial resolution in the extreme ultraviolet and X-ray regions, limited only by the wavelength of the light. Recently, advances in coherent short…
In this paper we present a novel high-resolution multi-channel FPGA-based time-to-digital converter (TDC). We designed and implemented a complex electronic circuit on the FPGA, whose overall accuracy is several orders of magnitude greater…
We propose a newly configured optical correlation-domain reflectometry (OCDR) without the use of an electrical spectrum analyzer (ESA) for high-speed distributed reflectivity measurement with an enhanced spatial resolution. First, the…
We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator…
A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $\sigma_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with…