Related papers: Performance evaluation of novel square-bordered po…
A new technique for detection of slow neutrons with gaseous detectors using ultra-thin layers with 10B atoms is presented. The reaction between a thermal neutron and a 10B atom releases 2 secondary particles, namely a 7Li ion and an alpha…
A new silicon detector has been developed to provide the PHENIX experiment with precise charged particle tracking at forward and backward rapidity. The Forward Silicon Vertex Tracker (FVTX) was installed in PHENIX prior to the 2012 run…
We report a high Responsivity broad band photo-detector working in the wavelength range 400 nm to 1100 nm in a horizontal array of Si microlines (line width ~1 micron) fabricated on a Silicon-on-Insulator (SOI) wafer. The array was made…
Detectors at future high energy colliders will face enormous technical challenges. Disentangling the unprecedented numbers of particles expected in each event will require highly granular silicon pixel detectors with billions of readout…
We report simulation studies of six low-energy electron-antineutrino detector designs, with the goal of determining their ability to resolve the direction to an antineutrino source. Such detectors with target masses on the one-ton scale are…
The in-beam tests of two Si pixel type TRACE detectors have been performed at Laboratori Nazionali di Legnaro (Italy). The aim was to investigate the possibility of identifying heavy-ion reactions products with mass A~10 at low kinetic…
The development of Low-Gain Avalanche Detectors has opened up the possibility of manufacturing silicon detectors with signal larger than that of traditional sensors. In this paper we explore the timing performance of Low-Gain Avalanche…
New design of silicon stripixel sensor has been developed at BNL for PHENIX upgrade. The sensor is a single-sided, DC-coupled, two dimensional position sensitive device with good position resolution. This design is simpler for sensor…
In this paper, the design and the performance of two prototype detectors based on Micromegas technology with a pad readout geometry is discussed. In addition, two alternative implementations of a spark-resistent protection layer on top of…
Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detection technology that can, in principle, provide significantly greater responsivity and improved noise performance than traditional charge coupled device (CCD)…
The Spherical Proportional Counter is a novel type of radiation detector, with a low energy threshold (typically below 100 eV) and good energy resolution. This detector is being developed by the network NEWS, which includes several…
Future X-ray astrophysics missions will survey large areas of the sky with unparalleled sensitivity, enabled by lightweight, high-resolution optics. These optics inherently produce curved focal surfaces with radii as small as 2 m, requiring…
Detectors with an electroluminesence readout show an excellence performance in respect of energy resolution making them interesting for various applications as X-ray detection, double beta and dark matter experiments, Compton and gamma…
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget…
We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is…
In the field of high-energy particle detection, detectors operating in high-radiation environments primarily face high costs associated with power consumption and cooling systems. Therefore, the development of particle detectors capable of…
A normal pressure MWPC for beam diagnostics at RIBLL2 has been developed, which has a sensitive area of 80 mm$\times$80 mm and consists of three-layer wire planes. The anode plane is designed with a wider frame to reduce the discharge and…
Micromegas technology is a promising candidate to replace Atlas forward muon chambers -tracking and trigger- for future HL-LHC upgrade of the experiment. The increase on background and pile-up event probability requires detector…
The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R\&D program, aiming at using 3D pixel…
The method of pulse-shape analysis (PSA) for particle identification (PID) was applied to a double-sided silicon strip detector (DSSD) with a strip pitch of 300 \{mu}m. We present the results of test measurements with particles from the…