English
Related papers

Related papers: Performance evaluation of novel square-bordered po…

200 papers

The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The…

We present our latest ASIC, which is used for the readout of Cadmium Telluride double-sided strip detectors (CdTe DSDs) and high spectroscopic imaging. It is implemented in a 0.35 um CMOS technology (X-Fab XH035), consists of 64 readout…

Instrumentation and Detectors · Physics 2020-09-02 Tenyo Kawamura , Tadashi Orita , Shin'ichiro Takeda , Shin Watanabe , Hirokazu Ikeda , Tadayuki Takahashi

The stopping cross sections S (E) of silicon for protons and alpha particles have been measured over the velocity range 0.3-1.2 MeV/u from a SIMOX target using the Rutherford Backscattering Spectrometry (RBS) with special emphasis put on…

Instrumentation and Detectors · Physics 2021-10-01 M. Abdesselam , S. Ouichaoui , M. Azzouz , A. C. Chami , M. Siad

We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from…

Instrumentation and Detectors · Physics 2023-11-16 M. F. Albakry , I. Alkhatib , D. Alonso , D. W. P. Amaral , P. An , T. Aralis , T. Aramaki , I. J. Arnquist , I. Ataee Langroudy , E. Azadbakht , S. Banik , P. S. Barbeau , C. Bathurst , R. Bhattacharyya , P. L. Brink , R. Bunker , B. Cabrera , R. Calkins , R. A. Cameron , C. Cartaro , D. G. Cerdeño , Y. -Y. Chang , M. Chaudhuri , R. Chen , N. Chott , J. Cooley , H. Coombes , J. Corbett , P. Cushman , S. Das , F. De Brienne , M. Rios , S. Dharani , M. L. di Vacri , M. D. Diamond , M. Elwan , E. Fascione , E. Figueroa-Feliciano , C. W. Fink , K. Fouts , M. Fritts , G. Gerbier , R. Germond , M. Ghaith , S. R. Golwala , J. Hall , N. Hassan , S. C. Hedges , B. A. Hines , Z. Hong , E. W. Hoppe , L. Hsu , M. E. Huber , V. Iyer , V. K. S. Kashyap , M. H. Kelsey , A. Kubik , N. A. Kurinsky , M. Lee , A. Li , L. Li , M. Litke , J. Liu , Y. Liu , B. Loer , E. Lopez Asamar , P. Lukens , D. B. MacFarlane , R. Mahapatra , V. Mandic , N. Mast , A. J. Mayer , H. Meyer zu Theenhausen , . Michaud , E. Michielin , N. Mirabolfathi , B. Mohanty , B. Nebolsky , J. Nelson , H. Neog , V. Novati , J. L. Orrell , M. D. Osborne , S. M. Oser , W. A. Page , S. Pandey , R. Partridge , D. S. Pedreros , L. Perna , R. Podviianiuk , F. Ponce , S. Poudel , A. Pradeep , M. Pyle , W. Rau , E. Reid , R. Ren , T. Reynolds , A. Roberts , A. E. Robinson , J. Runge , T. Saab , D. Sadek , B. Sadoulet , I. Saikia , J. Sander , A. Sattari , B. Schmidt , R. W. Schnee , S. Scorza , B. Serfass , S. S. Poudel , D. J. Sincavage , P. Sinervo , Z. Speaks , J. Street , H. Sun , F. K. Thasrawala , D. Toback , R. Underwood , S. Verma , A. N. Villano , B. von Krosigk , S. L. Watkins , O. Wen , Z. Williams , M. J. Wilson , J. Winchell , K. Wykoff , S. Yellin , B. A. Young , T. C. Yu , B. Zatschler , S. Zatschler , A. Zaytsev , A. Zeolla , E. Zhang , L. Zheng , Y. Zheng , A. Zuniga

A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at…

We present an approach to construct position-sensitive silicon detectors with an integrated cooling circuit. Tests on samples demonstrate that a very modest liquid flow very effectively cool the devices up to a power dissipation of over…

Instrumentation and Detectors · Physics 2016-08-03 L. Andricek , M. Boronat , J. Fuster , I. Garcia , P. Gomis , C. Marinas , J. Ninkovic , M. Perello Rosello , M. A. Villarejo , M. Vos

For many years there has been an aspiration within the community to develop curved silicon detectors for particle physics applications. We present the results from 10 x 10cm low mass support modules as a part of the "ZeroMass" project that…

Instrumentation and Detectors · Physics 2025-03-07 Sam Moss , Zhidong Zhang , Adrian Bevan , Mark Bullough , Jens Dopke , Jag Mistry , Seth Zenz

A 3-D position sensitive neutron detector is being developed based on a plastic scintillator array. A double side SiPM readout is used to determine the depth of interaction (DOI) in each scintillator unit. In the preliminary test, the DOI…

Instrumentation and Detectors · Physics 2019-07-11 Yang Tian , Yidong Fu , Yulan Li , Yuanjing Li

One of candidates for the International Linear Collider(ILC)'s vertex detector is the Fine Pixel CCD (FPCCD) with a pixel size of 5 \times 5 (\mum^2). Sensor and readout systems are currently being studied and prototypes have been…

We study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining…

Instrumentation and Detectors · Physics 2018-03-14 Aiwu Zhang , Marcus Hohlmann , Babak Azmoun , Martin L. Purschke , Craig Woody

In the years between 2000 and 2002 several pre-series and series modules of the ATLAS EM barrel and end-cap calorimeter were exposed to electron, photon and pion beams. The performance of the calorimeter with respect to its finely segmented…

Instrumentation and Detectors · Physics 2019-08-14 Roberto Sacco

Pixel detectors are used in the innermost part of multi purpose experiments at the Large Hadron Collider (LHC) and are therefore exposed to the highest fluences of ionising radiation, which in this part of the detectors consists mainly of…

Instrumentation and Detectors · Physics 2010-01-21 T. Rohe , J. Acosta , A. Bean , S. Dambach , W. Erdmann , U. Langenegger , C. Martin , B. Meier , V. Radicci , J. Sibille , P. Trueb

Small-pitch 3D silicon pixel detectors have been investigated as radiation-hard candidates for the innermost layers of the HL-LHC pixel detector upgrades. Prototype 3D sensors with pixel sizes of 50$\times$50 and 25$\times$100 $\mu$m$^{2}$…

Instrumentation and Detectors · Physics 2018-09-18 J. Lange , G. Giannini , S. Grinstein , M. Manna , G. Pellegrini , D. Quirion , S. Terzo , D. Vázquez Furelos

For a long time, scintillator detectors have suffered from relatively weak spatial resolution due to various influencing factors. Additionally, the high cost of photomultiplier tubes (PMTs) has limited the widespread adoption of…

Instrumentation and Detectors · Physics 2025-04-29 S. K. Lv , C. S. Dai , D. D. Hu , T. C. Zhong , W. F. Wu , X. J. Wang

The development prospects of a scintillator-photodiode type detector with an improved energy resolution attaining few per cent, R from 1 to 2%, are considered. The main resolution components have been analyzed theoretically, their…

Instrumentation and Detectors · Physics 2007-05-23 S. V. Naydenov , V. D. Ryzhikov

We report spectral and imaging performance of a pixelated CdZnTe detector custom designed for the \emph{MeVCube} project: a small Compton telescope on a CubeSat platform. \emph{MeVCube} is expected to cover the energy range between…

Instrumentation and Methods for Astrophysics · Physics 2022-08-10 Giulio Lucchetta , Markus Ackermann , David Berge , Ingo Bloch , Rolf Bühler , Hermann Kolanoski , Wolfgang Lange , Francesco Zappon

In the past 10 years, two design innovations, the introduction of low internal gain (LGAD) and of resistive read-out (RSD), have radically changed the performance of silicon detectors. The LGAD mechanism, increasing the signal-to-noise…

For the purpose of withstanding very high radiation doses, silicon pixel sensors with a 3D electrode geometry are being developed. Detectors of this kind are highly interesting for harch radiation environments such as expected in the High…

We have developed a silicon pixel detector to enhance the physics capabilities of the PHENIX experiment. This detector, consisting of two layers of sensors, will be installed around the beam pipe at the collision point and covers a…

A novel read-out architecture has been developed for the Micromegas detector. The anode element is made of a resistive layer on a ceramic substrate. The detector part is entirely separated from the read-out element. Without significant…

Instrumentation and Detectors · Physics 2015-06-11 D. Attie , A. Chaus , P. Colas , E. Ferrer , J. Galan , I. Giomatari , F. J. Iguaz , A. Gongadze , R. De Oliveira , T. Papaevangelou , A. Peyaud
‹ Prev 1 3 4 5 6 7 10 Next ›