English
Related papers

Related papers: A Silicon-Tungsten ECal with Integrated Electronic…

200 papers

A novel design for a silicon-tungsten electromagnetic calorimeter is described, based on Monolithic Active Pixel Sensors (MAPS). A test sensor with a pixel size of 50x50 um2 has been fabricated in July 2007. The simulation of the physical…

The electromagnetic calorimeter (ECAL) is a key detector component for precise electron and photon measurements in electron-ion collision experiments. At the Electron-Ion Collider in China (EicC), high-performance calorimetry is essential…

Instrumentation and Detectors · Physics 2026-03-23 Ye Tian , Souvik Maity , Jingyu Li , Yuancai Wu , Shan Sha , Yutie Liang , Aiqiang Guo , Yuxiang Zhao , Dexu Lin

The CALICE collaboration is currently developing engineering prototypes of electromagnetic and hadronic calorimeters for a future linear collider detector. This detector is designed to be used in particle-flow based event reconstruction. In…

Instrumentation and Detectors · Physics 2019-08-13 Mark Terwort

In this article we describe the commissioning and a first analysis of the the beam test performance of a small prototype of a highly granular silicon tungsten calorimeter. The prototype features detector elements with a channel number…

The CALICE Collaboration is carrying out research and development into calorimetry for a detector at the International Linear Collider (ILC). CALICE is investigating a range of technologies for both electromagnetic and hadronic calorimetry.…

Instrumentation and Detectors · Physics 2019-08-13 D. S. Bailey

We present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage…

A highly granular electromagnetic calorimeter prototype based on tungsten absorber and sampling units equipped with silicon pads as sensitive devices for signal collection is under construction. The full prototype will have in total 30…

Instrumentation and Detectors · Physics 2007-05-23 G. Mavromanolakis

The highly granular silicon-tungsten electromagnetic calorimeter (SiW ECAL) is the reference design of the ECAL for the International Large Detector (ILD) concept, one of the two detector concepts proposed for the future International…

Instrumentation and Detectors · Physics 2020-06-24 Adrian Irles

The CALICE collaboration is currently developing an engineering prototype of an analog hadron calorimeter for a future linear collider like the ILC. One main task of this prototype is to demonstrate the feasibility of building a realistic…

Instrumentation and Detectors · Physics 2019-08-14 Benjamin Hermberg

The CALICE collaboration is developing an engineering prototype of an analog hadron calorimeter for a future linear collider detector. The prototype has to prove the feasibility of building a realistic detector with fully integrated…

Instrumentation and Detectors · Physics 2019-08-13 Oskar Hartbrich , Mark Terwort

New generation high-energy physics experiments demand high precision tracking and accurate measurements of a large number of particles produced in the collisions of lementary particles and heavy-ions. Silicon-tungsten (Si-W) calorimeters…

A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here…

Instrumentation and Detectors · Physics 2014-11-20 C. Adloff , Y. Karyotakis , J. Repond , J. Yu , G. Eigen , Y. Mikami , N. K. Watson , J. A. Wilson , T. Goto , G. Mavromanolakis , M. A. Thomson , D. R. Ward , W. Yan , D. Benchekroun , A. Hoummada , Y. Khoulaki , J. Apostolakis , A. Ribon , V. Uzhinskiy , M. Benyamna , C. Cârloganu , F. Fehr , P. Gay , G. C. Blazey , D. Chakraborty , A. Dyshkant , K. Francis , D. Hedin , J. G. Lima , V. Zutshi , J. -Y. Hostachy , K. Krastev , L. Morin , N. D'Ascenzo , U. Cornett , D. David , R. Fabbri , G. Falley , K. Gadow , E. Garutti , P. Göttlicher , T. Jung , S. Karstensen , A. -I. Lucaci-Timoce , B. Lutz , N. Meyer , V. Morgunov , M. Reinecke , F. Sefkow , P. Smirnov , A. Vargas-Trevino , N. Wattimena , O. Wendt , N. Feege , M. Groll , J. Haller , R. -D. Heuer , S. Morozov , S. Richter , J. Samson , A. Kaplan , H. -Ch. Schultz-Coulon , W. Shen , A. Tadday , B. Bilki , E. Norbeck , Y. Onel , E. J. Kim , G. Kim , D-W. Kim , K. Lee , S. C. Lee , K. Kawagoe , Y. Tamura , P. D. Dauncey , A. -M. Magnan , H. Yilmaz , O. Zorba , V. Bartsch , M. Postranecky , M. Warren , M. Wing , M. G. Green , F. Salvatore , M. Bedjidian , R. Kieffer , I. Laktineh , M. -C. Fouz , D. S. Bailey , R. J. Barlow , M. Kelly , R. J. Thompson , M. Danilov , E. Tarkovsky , N. Baranova , D. Karmanov , M. Korolev , M. Merkin , A. Voronin , A. Frey , S. Lu , K. Seidel , F. Simon , C. Soldner , L. Weuste , J. Bonis , B. Bouquet , S. Callier , P. Cornebise , Ph. Doublet , M. Faucci Giannelli , J. Fleury , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Poeschl , L. Raux , N. Seguin-Moreau , F. Wicek , M. Anduze , V. Boudry , J-C. Brient , G. Gaycken , D. Jeans , P. Mora de Freitas , G. Musat , M. Reinhard , A. Rougé , M. Ruan , J-Ch. Vanel , H. Videau , K-H. Park , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , M. Belmir , S. W. Nam , I. H. Park , J. Yang , Jong-Seo Chai , Jong-Tae Kim , Geun-Bum Kim , J. Kang , Y. -J. Kwon

High channel density and space restrictions required that the front end electronics integrated into the active elements of calorimeter. For that purpose novel readout chain base on Application-Specific Integrated Circuit (ASIC) designed for…

Instrumentation and Detectors · Physics 2012-10-19 Elmaddin Guliyev

Excellent jet energy measurement is important at the International Linear Collider (ILC) because most of interesting physics processes decay into multi-jet final states. We employ a particle flow method to reconstruct particles, hence…

A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm$^2$) and tungsten absorbers (each of one radiation length), has been constructed for measurement of…

We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that is based on plastic scintillator tiles readout with silicon photomultipliers. In this work, we concretize its design by characterizing its…

Instrumentation and Detectors · Physics 2023-05-30 Miguel Arratia , Luis Garabito Ruiz , Jiajun Huang , Sebouh J. Paul , Sean Preins , Miguel Rodriguez

The basic prototype of a tile hadron calorimeter (HCAL) for the International Linear Collider (ILC) has been realised and extensively tested. A major aspect of the proposed concept is the improvement of the jet energy resolution by…

Instrumentation and Detectors · Physics 2016-10-10 Aliakbar Ebrahimi

To evaluate different technologies for calorimetry at the International Linear Collider, the CALICE collaboration has constructed a highly granular analog hadron calorimeter with small scintillator cells, individually read out by silicon…

Instrumentation and Detectors · Physics 2019-08-13 Frank Simon

The CALICE collaboration develops prototypes for highly granular calorimeters for detectors at a future linear electron positron collider. The highly granular electromagnetic calorimeter prototype was tested in particle beams. We present…

Instrumentation and Detectors · Physics 2019-08-13 Roman Pöschl

High precision physics at future colliders as the International Linear Collider (ILC) require unprecedented high precision in the determination of the energy of final state particles. The needed precision will be achieved thanks to the…

Instrumentation and Detectors · Physics 2018-02-27 Adrián Irles