English
Related papers

Related papers: Design and Implementation of the New D0 Level-1 Ca…

200 papers

We review the diffractive measurements made by the CDF and D\O\ collaborations during Run I at the Tevatron and summarize the detector upgrades relevant for the Run II diffractive physics program.

High Energy Physics - Phenomenology · Physics 2017-08-23 L. Demortier

High precision physics at future colliders requires unprecedented highly granular calorimeters for the application of the Particle Flow (PF) algorithm. The physical proof of concept was given in the previous campaign of beam tests of physic…

Instrumentation and Detectors · Physics 2018-07-01 Adrián Irles

The trigger selection capabilities of the ATLAS detector have been significantly enhanced for the LHC Run- 2 in order to cope with the higher event rates and with the large number of simultaneous interactions (pile-up) per protonproton…

High Energy Physics - Experiment · Physics 2020-09-18 Pierre-Hugues Beauchemin

The ICARUS liquid argon TPC detector is taking data on the Booster (BNB) and Main Injector (NuMI) Neutrino beam lines at Fermilab with a trigger system based on the scintillation light produced by charged particles in coincidence with the…

High Energy Physics - Experiment · Physics 2026-02-19 ICARUS collaboration , F. Abd Alrahman , P. Abratenko , N. Abrego-Martinez , A. Aduszkiewicz , F. Akbar , L. Aliaga Soplin , M. Artero Pons , J. Asaadi , W. F. Badgett , B. Baibussinov , F. Battisti , V. Bellini , R. Benocci , J. Berger , S. Berkman , S. Bertolucci , M. Betancourt , A. Blanchet , F. Boffelli , M. Bonesini , T. Boone , B. Bottino , A. Braggiotti , D. Brailsford , S. J. Brice , V. Brio , C. Brizzolari , H. S. Budd , A. Campani , A. Campos , D. Carber , M. Carneiro , I. Caro Terrazas , H. Carranza , F. Castillo Fernandez , S. Centro , G. Cerati , A. Chatterjee , D. Cherdack , S. Cherubini , N. Chithirasreemadam , M. Cicerchia , T. E. Coan , A. Cocco , M. R. Convery , L. Cooper-Troendle , S. Copello , H. Da Motta , M. Dallolio , A. A. Dange , A. de Roeck , S. Di Domizio , D. Di Ferdinando , L. Di Noto , M. Diwan , S. Dolan , L. Domine , S. Donati , F. Drielsma , J. Dyer , S. Dytman , A. Falcone , C. Farnese , A. Fava , N. Gallice , F. G. Garcia , C. Gatto , D. Gibin , A. Gioiosa , W. Gu , A. Guglielmi , G. Gurung , K. Hassinin , H. Hausner , A. Heggestuen , B. Howard , R. Howell , Z. Hulcher , I. Ingratta , C. James , W. Jang , Y. -J. Jwa , L. Kashur , W. Ketchum , J. S. Kim , D. -H. Koh , T. Krishnan , J. Larkin , Y. Li , C. Mariani , C. M. Marshall , S. Martynenko , N. Mauri , K. S. McFarland , A. Menegolli , G. Meng , O. G. Miranda , A. Mogan , N. Moggi , E. Montagna , A. Montanari , C. Montanari , M. Mooney , G. Moreno-Granados , J. Mueller , M. Murphy , D. P. Méndez , D. Naples , S. Palestini , M. Pallavicini , V. Paolone , L. Pasqualini , L. Patrizii , L. Paudel , G. Petrillo , C. Petta , V. Pia , F. Pietropaolo , F. Poppi , M. Pozzato , M. L. Pumo , G. Putnam , X. Qian , A. Rappoldi , G. L. Raselli , S. Repetto , F. Resnati , A. M. Ricci , E. Richards , M. Rosenberg , M. Rossella , N. Rowe , P. Roy , C. Rubbia , M. Saad , S. Saha , G. Salmoria , S. Samanta , A. Scaramelli , D. Schmitz , A. Schukraft , D. Senadheera , S-H. Seo , F. Sergiampietri , G. Sirri , J. S. Smedley , J. Smith , M. Sotgia , L. Stanco , J. Stewart , H. A. Tanaka , M. Tenti , K. Terao , F. Terranova , V. Togo , D. Torretta , M. Torti , F. Tortorici , D. Totani , R. Triozzi , Y. -T. Tsai , K. V. Tsang , T. Usher , F. Varanini , N. Vardy , S. Ventura , M. Vicenzi , C. Vignoli , B. Viren , F. A. Wieler , Z. Williams , P. Wilson , R. J. Wilson , J. Wolfs , T. Wongjirad , A. Wood , E. Worcester , M. Worcester , M. Wospakrik , J. Xia , S. Yadav , H. Yu , J. Yu , A. Zani , J. Zennamo , J. Zettlemoyer , C. Zhang , S. Zucchelli

The upgrade to the ATLAS trigger for LHC Run 2 is presented including a description of the design and performance of the newly reimplemented tracking algorithms. The profiling infrastructure, constructed to provide prompt feedback from the…

Instrumentation and Detectors · Physics 2019-08-13 Benjamin Sowden

The NO$\nu$A collaboration has constructed a 14,000 ton, fine-grained, low-Z, total absorption tracking calorimeter at an off-axis angle to an upgraded NuMI neutrino beam. This detector, with its excellent granularity and energy resolution…

High Energy Physics - Experiment · Physics 2015-11-03 R. Mina , E. Culbertson , M. J. Frank , R. C. Group , A. Norman , I. Oksuzian

Precision physics at future multi-TeV lepton colliders such as CLIC requires excellent jet energy resolution. The detectors need deep calorimeter systems to limit the energy leakage also for very highly energetic particles and jets. At the…

Instrumentation and Detectors · Physics 2019-08-13 Frank Simon

The general strategy, as well as channel-specific details, applied to the measurement of the top quark mass at the Tevatron in Run I are reviewed, and the combination of the results obtained by the CDF and DO collaborations presented. The…

High Energy Physics - Experiment · Physics 2007-05-23 G. Brooijmans

This article describes the Laser calibration system of the Atlas hadronic Tile Calorimeter that has been used during the run 1 of the LHC. First, the stability of the system associated readout electronics is studied. It is found to be…

Instrumentation and Detectors · Physics 2016-10-13 ATLAS Tile Calorimeter system

The ATLAS experiment at the Large Hadron Collider (LHC) will face the challenge of efficiently selecting interesting candidate events in $pp$ collisions at 14 TeV centre-of-mass energy, whilst rejecting the enormous number of background…

Instrumentation and Detectors · Physics 2008-10-21 Tomasz Bold , for Atlas Tdaq

This talk reports on recent progress concerning the development of a Digital Hadron Calorimeter with Resistive Plate Chambers as active elements. After the successful testing of a Digital Hadron Calorimeter prototype, the DHCAL, in the…

Instrumentation and Detectors · Physics 2013-12-16 J. Repond

The FCAL collaboration is preparing large scale prototypes of special calorimeters to be used in the very forward region at a future linear electron positron collider for a precise and fast luminosity measurement and beam-tuning. These…

Instrumentation and Detectors · Physics 2017-03-08 V. Ghenescu , Y. Benhammou

The Muon $g-2$ experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A…

The ATLAS detector at CERN's Large Hadron Collider (LHC) will be exposed to proton-proton collisions from beams crossing at 40 MHz. At the design luminosity of 10^34 cm^-2 s^-1 there are on average 23 collisions per bunch crossing. A…

Instrumentation and Detectors · Physics 2014-11-18 David Berge

The ALICE (A Large Ion Collider Experiment) detector yields a huge sample of data from different sub-detectors. On-line data processing is applied to select and reduce the volume of the stored data. ALICE applies a multi-level hardware…

Instrumentation and Detectors · Physics 2019-08-14 F. Ronchetti , F. Blanco , M. Figueredo , A. G. Knospe , L. Xaplanteris

The LHCb experiment at CERN is undergoing an upgrade in preparation for the Run 3 data taking period of the LHC. As part of this upgrade the trigger is moving to a fully software implementation operating at the LHC bunch crossing rate. We…

Instrumentation and Detectors · Physics 2022-01-06 R. Aaij , M. Adinolfi , S. Aiola , S. Akar , J. Albrecht , M. Alexander , S. Amato , Y. Amhis , F. Archilli , M. Bala , G. Bassi , L. Bian , M. P. Blago , T. Boettcher , A. Boldyrev , S. Borghi , A. Brea Rodriguez , L. Calefice , M. Calvo Gomez , D. H. Cámpora Pérez , A. Cardini , M. Cattaneo , V. Chobanova , G. Ciezarek , X. Cid Vidal , J. L. Cobbledick , J. A. B. Coelho , T. Colombo , A. Contu , B. Couturier , D. C. Craik , R. Currie , P. d'Argent , M. De Cian , D. Derkach , F. Dordei , M. Dorigo , L. Dufour , P. Durante , A. Dziurda , A. Dzyuba , S. Easo , S. Esen , P. Fernandez Declara , S. Filippov , C. Fitzpatrick , M. Frank , P. Gandini , V. V. Gligorov , E. Golobardes , G. Graziani , L. Grillo , P. A. Günther , S. Hansmann-Menzemer , A. M. Hennequin , L. Henry , D. Hill , S. E. Hollitt , J. Hu , W. Hulsbergen , R. J. Hunter , M. Hushchyn , B. K. Jashal , C. R. Jones , S. Klaver , K. Klimaszewski , R. Kopecna , W. Krzemien , M. Kucharczyk , R. Lane , F. Lazzari , R. Le Gac , P. Li , J. H. Lopes , M. Lucio Martinez , A. Lupato , O. Lupton , X. Lyu , F. Machefert , O. Madejczyk , S. Malde , J. F. Marchand , S. Mariani , C. Marin Benito , D. Martinez Santos , F. Martinez Vidal , R. Matev , M. Mazurek , B. Mitreska , D. S. Mitzel , M. J. Morello , H. Mu , P. Muzzetto , P. Naik , M. Needham , N. Neri , N. Neufeld , N. S. Nolte , D. O'Hanlon , A. Oyanguren , M. Pepe Altarelli , S. Petrucci , M. Petruzzo , L. Pica , F. Pisani , A. Piucci , F. Polci , A. Poluektov , E. Polycarpo , C. Prouve , G. Punzi , R. Quagliani , R. I. Rabadan Trejo , M. Ramos Pernas , M. S. Rangel , F. Ratnikov , G. Raven , F. Reiss , V. Renaudin , P. Robbe , A. Ryzhikov , M. Santimaria , M. Saur , M. Schiller , R. Schwemmer , B. Sciascia , A. Solomin , F. Suljik , N. Skidmore , M. D. Sokoloff , P. Spradlin , M. Stahl , S. Stahl , H. Stevens , L. Sun , A. Szabelski , T. Szumlak , M. Szymanski , D. Y. Tou , G. Tuci , A. Usachov , N. Valls Canudas , R. Vazquez Gomez , S. Vecchi , M. Vesterinen , X. Vilasis-Cardona , D. Vom Bruch , Z. Wang , T. Wojton , M. Whitehead , M. Williams , M. Witek , Y. Xie , A. Xu , H. Yin , M. Zdybal , O. Zenaiev , D. Zhang , L. Zhang , X. Zhu

The DZERO experiment located at Fermilab has recently started RunII with an upgraded detector. The RunII physics program requires the Data Acquisition to readout the detector at a rate of 1 KHz. Events fragments, totaling 250 KB, are…

The CDF-II experiment is a multipurpose detector designed to study a wide range of processes observed in the high energy proton-antiproton collisions produced by the Fermilab Tevatron. With event rates greater than 1MHz, the CDF-II trigger…

An optical link system is being developed for the ATLAS Liquid Argon Calorimeter Phase-II upgrade. The optical link system is responsible for transmit the data of over 182 thousand detector channels from 1524 Front-End Boards (FEBs) through…

Instrumentation and Detectors · Physics 2020-08-03 B. Deng , C. Liu , D. Gong , X. Huang , S. Hou , T. Liu , H. Sun , L. Zhang , W. Zhang , J. Ye

The 4th Concept detector presently being designed for the International Linear Collider introduces several innovations in order to achieve the necessary experimental goal of a detecter that is 2-to-10 times better than the already excellent…

High Energy Physics - Experiment · Physics 2007-08-06 Sung Keun Park , Franco Grancagnolo , John Hauptman , Alexander Mikhailichenko , Nural Akchurin