English
Related papers

Related papers: First performance studies of a prototype for the C…

200 papers

The key parameters of Cherenkov Correlated Timing (CCT) detectors are discussed. Measurements of radiator geometry, optical properties of radiator and coupling materials, and photon detector timing performance are presented.

The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section…

Instrumentation and Detectors · Physics 2022-05-25 B. Acar , G. Adamov , C. Adloff , S. Afanasiev , N. Akchurin , B. Akgün , F. Alam Khan , M. Alhusseini , J. Alison , A. Alpana , G. Altopp , M. Alyari , S. An , S. Anagul , I. Andreev , P. Aspell , I. O. Atakisi , O. Bach , A. Baden , G. Bakas , A. Bakshi , S. Bannerjee , P. Bargassa , D. Barney , F. Beaudette , F. Beaujean , E. Becheva , A. Becker , P. Behera , A. Belloni , T. Bergauer , M. Besancon , S. Bhattacharya , D. Bhowmik , B. Bilki , P. Bloch , A. Bodek , M. Bonanomi , A. Bonnemaison , S. Bonomally , J. Borg , F. Bouyjou , N. Bower , D. Braga , J. Brashear , E. Brondolin , P. Bryant , A. Buchot Perraguin , J. Bueghly , B. Burkle , A. Butler-Nalin , O. Bychkova , S. Callier , D. Calvet , X. Cao , A. Cappati , B. Caraway , S. Caregari , A. Cauchois , L. Ceard , Y. C. Cekmecelioglu , S. Cerci , G. Cerminara , M. Chadeeva , N. Charitonidis , R. Chatterjee , Y. M. Chen , Z. Chen , H. J. Cheng , K. y. Cheng , S. Chernichenko , H. Cheung , C. H. Chien , S. Choudhury , D. Čoko , G. Collura , F. Couderc , M. Danilov , D. Dannheim , W. Daoud , P. Dauncey , A. David , G. Davies , O. Davignon , E. Day , P. DeBarbaro , F. De Guio , C. de La Taille , M. De Silva , P. Debbins , M. M. Defranchis , E. Delagnes , J. M. Deltoro Berrio , G. Derylo , P. G. Dias de Almeida , D. Diaz , P. Dinaucourt , J. Dittmann , M. Dragicevic , S. Dugad , F. Dulucq , I. Dumanoglu , V. Dutta , S. Dutta , M. Dünser , J. Eckdahl , T. K. Edberg , M. El Berni , F. Elias , S. C. Eno , Yu. Ershov , P. Everaerts , S. Extier , F. Fahim , C. Fallon , G. Fedi , B. A. Fontana Santos Alves , E. Frahm , G. Franzoni , J. Freeman , T. French , P. Gandhi , S. Ganjour , X. Gao , A. Garcia-Bellido , F. Gastaldi , Z. Gecse , Y. Geerebaert , H. Gerwig , O. Gevin , S. Ghosh , A. Gilbert , W. Gilbert , K. Gill , C. Gingu , S. Gninenko , A. Golunov , I. Golutvin , T. Gonzalez , N. Gorbounov , L. Gouskos , A. B. Gray , Y. Gu , F. Guilloux , Y. Guler , E. Gülmez , J. Guo , E. Gurpinar Guler , M. Hammer , H. M. Hassanshahi , K. Hatakeyama , A. Heering , V. Hegde , U. Heintz , N. Hinton , J. Hirschauer , J. Hoff , W. -S. Hou , X. Hou , H. Hua , J. Incandela , A. Irshad , C. Isik , S. Jain , H. R. Jheng , U. Joshi , V. Kachanov , A. Kalinin , L. Kalipoliti , A. Kaminskiy , A. Kapoor , O. Kara , A. Karneyeu , M. Kaya , O. Kaya , A. Kayis Topaksu , A. Khukhunaishvili , J. Kiesler , M. Kilpatrick , S. Kim , K. Koetz , T. Kolberg , O. K. Köseyan , A. Kristić , M. Krohn , K. Krüger , N. Kulagin , S. Kulis , S. Kunori , C. M. Kuo , V. Kuryatkov , S. Kyre , Y. Lai , K. Lamichhane , G. Landsberg , C. Lange , J. Langford , M. Y. Lee , A. Levin , A. Li , B. Li , J. H. Li , Y. y. Li , H. Liao , D. Lincoln , L. Linssen , R. Lipton , Y. Liu , A. Lobanov , R. -S. Lu , M. Lupi , I. Lysova , A. -M. Magnan , F. Magniette , A. Mahjoub , A. A. Maier , A. Malakhov , S. Mallios , I. Mandjavize , M. Mannelli , J. Mans , A. Marchioro , A. Martelli , G. Martinez , P. Masterson , B. Meng , T. Mengke , A. Mestvirishvili , I. Mirza , S. Moccia , G. B. Mohanty , F. Monti , I. Morrissey , S. Murthy , J. Musić , Y. Musienko , S. Nabili , A. Nagar , M. Nguyen , A. Nikitenko , D. Noonan , M. Noy , K. Nurdan , C. Ochando , B. Odegard , N. Odell , H. Okawa , Y. Onel , W. Ortez , J. Ozegović , S. Ozkorucuklu , E. Paganis , D. Pagenkopf , V. Palladino , S. Pandey , F. Pantaleo , C. Papageorgakis , I. Papakrivopoulos , J. Parshook , N. Pastika , M. Paulini , P. Paulitsch , T. Peltola , R. Pereira Gomes , H. Perkins , P. Petiot , T. Pierre-Emile , F. Pitters , E. Popova , H. Prosper , M. Prvan , I. Puljak , H. Qu , T. Quast , R. Quinn , M. Quinnan , M. T. Ramos Garcia , K. K. Rao , K. Rapacz , L. Raux , G. Reichenbach , M. Reinecke , M. Revering , A. Roberts , T. Romanteau , A. Rose , M. Rovere , A. Roy , P. Rubinov , R. Rusack , V. Rusinov , V. Ryjov , O. M. Sahin , R. Salerno , A. M. Sanchez Rodriguez , R. Saradhy , T. Sarkar , M. A. Sarkisla , J. B. Sauvan , I. Schmidt , M. Schmitt , E. Scott , C. Seez , F. Sefkow , S. Sharma , I. Shein , A. Shenai , R. Shukla , E. Sicking , P. Sieberer , P. Silva , A. E. Simsek , Y. Sirois , V. Smirnov , U. Sozbilir , E. Spencer , A. Steen , J. Strait , N. Strobbe , J. W. Su , E. Sukhov , L. Sun , D. Sunar Cerci , C. Syal , B. Tali , C. L. Tan , J. Tao , I. Tastan , T. Tatli , R. Thaus , S. Tekten , D. Thienpont , E. Tiras , M. Titov , D. Tlisov , U. G. Tok , J. Troska , L. -S. Tsai , Z. Tsamalaidze , G. Tsipolitis , A. Tsirou , N. Tyurin , S. Undleeb , D. Urbanski , V. Ustinov , A. Uzunian , M. Van de Klundert , J. Varela , M. Velasco , O. Viazlo , M. Vicente Barreto Pinto , P. Vichoudis T. Virdee , R. Vizinho de Oliveira , J. Voelker , E. Voirin , M. Vojinovic , A. Wade , C. Wang , F. Wang , X. Wang , Z. Wang , Z. Wang , M. Wayne , S. N. Webb , A. Whitbeck , D. White , R. Wickwire , J. S. Wilson , D. Winter , H. y. Wu , L. Wu , M. Wulansatiti Nursanto , C. H Yeh , R. Yohay , D. Yu , G. B. Yu , S. S. Yu , C. Yuan , F. Yumiceva , I. Yusuff , A. Zacharopoulou , N. Zamiatin , A. Zarubin , S. Zenz , A. Zghiche , H. Zhang , J. Zhang , Y. Zhang , Z. Zhang

A lead scintillator sandwich sampling calorimeter has been installed in the HERA tunnel 105.6 m from the central ZEUS detector in the proton beam direction. It is designed to measure the energy and scattering angle of neutrons produced in…

One of the three X-ray detectors of the CAST experiment searching for solar axions is a Time Projection Chamber (TPC) with a multi-wire proportional counter (MWPC) as a readout structure. Its design has been optimized to provide high…

This paper presents performance measurements of a new readout electronics system based on silicon photomultipliers for the PHENIX electromagnetic calorimeter. Installation of the lead-scintillator Shashlik style calorimeter into the…

The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of…

The CMS experiment is a multi-purpose detector successfully operated at the LHC where predominantly pp collisions take place at various centre-of-mass energies up to sqrt(s)=8 TeV so far. Several weeks per year also heavy-ion collisions…

High Energy Physics - Experiment · Physics 2014-08-19 Lars Sonnenschein

TORCH is a time-of-flight detector designed to perform particle identification over the momentum range 2$-$10 GeV/c for a 10 m flight path. The detector exploits prompt Cherenkov light produced by charged particles traversing a quartz plate…

The installation of the High-Luminosity Large Hadron Collider (HL-LHC) presents unprecedented challenges to experiments like the Compact Muon Solenoid (CMS) in terms of event rate, integrated luminosity and therefore radiation exposures. To…

Instrumentation and Detectors · Physics 2020-08-26 Peter Paulitsch

The anticipated use of more than one thousand lead fluoride (PbF2) crystals as a fast and compact Cherenkov calorimeter material in a parity violation experiment at MAMI stimulated the investigation of the light yield (L.Y.) of these…

Nuclear Experiment · Physics 2009-02-23 P. Achenbach , S. Baunack , K. Grimm , T. Hammel , D. von Harrach , A. Lopes Ginja , F. E. Maas , E. Schilling , H. Stroeher

Studies are presented of the selection of events consistent with top quark pair production in data recorded by the CMS detector at the LHC, corresponding to an integrated luminosity of 0.84+/-0.09 1/pb and at center-of-mass energy sqrt{s}=7…

High Energy Physics - Experiment · Physics 2010-10-13 Frank-Peter Schilling

In 2016, the Large Hadron Collider provided proton-proton collisions at 13 TeV center-of-mass energy and achieved very high luminosity and reliability. The performance of the CMS Experiment in this running period and a selection of recent…

High Energy Physics - Experiment · Physics 2017-09-12 Joel Nathan Butler

Calibration of the forward CMS hadron calorimeters in situ by the LHC beam is proposed. Simulations show that bent crystal channeling technique is feasible at the LHC, and report the experience of IHEP Protvino in bending 70 GeV protons by…

Accelerator Physics · Physics 2007-05-23 Yu. Chesnokov , V. Biryukov , V. Kryshkin

The operations of Resistive Plate Chambers in LHC experiments require Fluorine based (F-based) gases for optimal performance. Recent European regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In…

The ALICE experiment at LHC studies the strong interaction sector of the Standard Model with pp, pA and AA collisions. Within the scope of the physics program, measurements of photons, neutral mesons and jets in ALICE are performed by two…

Instrumentation and Detectors · Physics 2018-10-11 Yuri Kharlov

A low background Micromegas detector has been operating on the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector operated efficiently and achieved a very low level of…

Hadronic Forward(HF) detector is one of the sub-detectors of the CMS. It plays an important role in the measurement of forward jets and missing energy. HF is situated on both sides of the CMS interaction point, at about $\pm$11 m, covers…

Instrumentation and Detectors · Physics 2020-09-23 Yalcin Guler

The performance of the electromagnetic calorimeter of the ALICE experiment during operation in 2010-2018 at the Large Hadron Collider is presented. After a short introduction into the design, readout, and trigger capabilities of the…

Instrumentation and Detectors · Physics 2023-10-02 ALICE Collaboration

In experimental nuclear physics (NP), high-precision electromagnetic calorimetry typically requires a good energy resolution and linear photosensor response on the level of (1-2)% over a full dynamic range of the detector. The beam of…

Instrumentation and Detectors · Physics 2025-10-22 Vladimir V. Berdnikov , Alexander Somov

The gaseous Micromegas detector designed for the CERN Axion search experiment CAST, operated smoothly during Phase-I, which included the 2003 and 2004 running periods. It exhibited linear response in the energy range of interest (1-10keV),…

Instrumentation and Detectors · Physics 2008-11-26 S. Aune , T. Dafni , G. Fanourakis , E. Ferrer Ribas , T. Geralis , A. Giganon , Y. Giomataris , I. G. Irastorza , K. Kousouris , K. Zachariadou
‹ Prev 1 4 5 6 7 8 10 Next ›