Related papers: Pulse-shape discrimination with PbWO$_4$ crystal s…
CUPID-Mo is a cryogenic detector array designed to search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{100}$Mo. It uses 20 scintillating $^{100}$Mo-enriched Li$_2$MoO$_4$ bolometers instrumented with Ge light detectors to…
With the development of high-speed readout electronics, the digital pulse shape discrimination (PSD) methods have attracted the attention of more researchers, especially in the field of high energy physics and neutron detection. How to…
Fast electronic readout for high-channel density scintillator-based systems is needed for radiation tracking and imaging in a wide range of applications, including nuclear physics, nuclear security and nonproliferation. Programmable…
The use of programmable hardware devices is imperative for digital based pulse shape discrimination (PSD) to differentiate between various types of radiation. This work reports the development of a PSD algorithm based on tail area and total…
This paper discusses the quality and performance of currently available PbWO$_4$ crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned…
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent…
Solid-state scintillators are widely used in particle and applied physics due to their versatility and resistance to diverse environments and operating conditions. This broad range of applications calls for thorough characterization of…
Using the waveforms from a digital electronic system, an offline analysis technique on pulse shape discrimination (PSD) has been developed to improve the neutron-gamma separation in a bar-shaped NE-213 scintillator that couples to a…
Detailed characterization of the newly available plastic scintillator (EJ-299-33A) having the pulse shape discrimination (PSD) property has been carried out in case of a large-sized detector (5 in.$\times$5 in.). The pulse height response…
A method for time differentiation based on a Babinet-Soleil-Bravais compensator is introduced. The complex transfer function of the device is measured using polarization spectral interferometry. Time differentiation of both the pulse field…
Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional…
A cadmium tungstate crystal boule enriched in $^{116}$Cd to 82% with mass of 1868 g was grown by the low-thermal-gradient Czochralski technique. The isotopic composition of cadmium and the trace contamination of the crystal were estimated…
A new R&D on lithium molybdate scintillators has begun within a project CLYMENE (Czochralski growth of Li$_2$MoO$_4$ crYstals for the scintillating boloMeters used in the rare EveNts sEarches). One of the main goals of the CLYMENE is a…
The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate…
A novel algorithm for the discrimination of neutron and {\gamma}-ray with wavelet transform modulus maximum (WTMM) in an organic scintillation has been investigated. Voltage pulses arising from a BC501A organic liquid scintillation detector…
In beam test experiments have been carried out for particle identification using digital pulse shape analysis in a 500~$\mu$m thick Neutron Transmutation Doped (nTD) silicon detector with an indigenously developed FPGA based 12 bit…
Electromagnetic calorimeters used in high-energy physics and astrophysics rely heavily on high-Z inorganic scintillators, such as lead tungstate (PbWO4 or PWO). The crystalline structure and lattice orientation of inorganic scintillators…
0.5%, 1%, 3% and 5% Ce-concentration single crystals of Tl2LiLuCl6 were grown from the melt using two zone vertical Bridgman technique. X-ray induced emission spectra showed Ce3+ emission between 370 nm and 540 nm wavelength range. Energy…
A hybrid dual-readout calorimeter concept, comprising both electromagnetic and hadronic sections, has recently been proposed to meet the performance requirements of experiments at future e$^{+}$e$^{-}$ colliders. The front compartment…
Water-based liquid scintillators (WbLS) present an attractive target medium for large-scale detectors with the ability to enhance the separation of Cherenkov and scintillation signals from a single target. This work characterizes the…