Instrumentation and Detectors
The true coincidence summing effect on the full-energy peak efficiency calibration of an unsuppressed clover HPGe detector has been studied. Standard multi-energetic and mono-energetic gamma-ray sources were used to determine the…
We extend the measurement range of optical correlation-domain reflectometry (OCDR) by modulating the laser output frequency at two frequencies, while preserving spatial resolution. We demonstrate distributed reflectivity sensing with a…
We report the scintillation spectra of Ar-CF$_4$ mixtures in the range 210-800~nm, obtained under X-ray irradiation for various pressures (1-5~bar) and concentrations (0-100%). Special care was taken to eliminate effects related to space…
In this paper we provide a detailed technical description of the Front-End (FE) electronics for the liquid Argon instrumentation of the LEGEND-200 experiment, searching for the very rare, hypothetical neutrinoless double $\beta$ decay…
The Large Hadron Collider (LHC) at CERN will undergo an upgrade in order to increase its luminosity to $7.5 \times 10^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosity during this High-Luminosity running phase (HL-LHC), starting around…
The response of Low Gain Avalanche Diodes (LGADs), which are a type of thin silicon detector with internal gain, to X-rays of energies between 6-70 keV was characterized at the SLAC light source (SSRL). The utilized beamline at SSRL was…
The characteristics of a hydrogenated amorphous silicon (a-Si:H) detector are presented here for monitoring in space solar flares and the evolution of large energetic proton events up to hundreds of MeV. The a-Si:H presents an excellent…
The online Data Quality Monitoring system (DQM) of the CMS electromagnetic calorimeter (ECAL) is a crucial operational tool that allows ECAL experts to quickly identify, localize, and diagnose a broad range of detector issues that would…
The Compressed Baryonic Matter (CBM) experiment is one of the major scientific spectrometers of the future Facility for Antiproton and Ion Research (FAIR) in Darmstadt. As one of the core sub-systems in CBM experiment for charged hadron…
Graphite is important reactor material used as a neutron moderator in various reactor designs. It is not only structural material used in previous reactors design but even material to which attention is focused due to the very…
Recent helium shortages and helium price increases have lead to an increased emphasis being placed on conserving helium. The need to conserve helium must be balanced with need to maintain the high levels of purity necessary to prevent…
Simulation tools have become an integral tool in the analysis of neutronic parameters of reactor units. These simulation tools are built to solve the neutron transport equation. In this article, the MCU-PTR simulation tool is used in the…
Quasi-monolithic interferometers play a crucial role in high-precision measurement experiments, including gravitational wave detection, inertial sensing, vibrometry, and seismology. Achieving high stability and accuracy in such…
In this work the linearity in the response of an ionization-chamber as a function of $^{99m}$Tc activity was checked as part of a calibration procedure for $^{192}$Ir activity measurements. The non-linearity was found to be caused mainly by…
Pixelated CdZnTe detectors are a promising imaging-spectrometer for gamma-ray astrophysics due to their combination of relatively high energy resolution with room temperature operation negating the need for cryogenic cooling. This reduces…
A novel beam profiler based on microstructured scintillation resin is presented. The detector consists of a bundle of waveguides, with an active area of 30 x 30 mm$^2$ and a pitch of 400 $\mu$m, obtained by molding a scintillating resin…
Constant ingress of impurities in Muon Campus g-2 experiment at Fermilab has resulted in reduction of efficiency of cryogenic expanders and occasional undesired downtime to flush the impurities. Due to insufficiency of current 60 g/s mobile…
Liquid Nitrogen precooling is used in most Cryoplants to achieve cooldown to 80 K temperature range. In one such system at Fermilab's CMTF Superfluid Cryoplant, where the Helium supply directly exchanges heat with liquid Nitrogen, freezing…
Time Delay Interferometry (TDI) is often utilized in the data pre-processing of space-based gravitational wave detectors, primarily for suppressing laser frequency noise. About twenty years ago, assuming armlengths remain constant over…
To increase the storage time of ultracold neutrons (UCN) inside the material traps it is promising to cover the trap walls by liquid 4He, the material which does not absorb neutrons at all. A rough side wall of UCN trap holds the required…