English

State-of-the-Art Flash Chips for Dosimetry Applications

Instrumentation and Detectors 2018-09-25 v1

Abstract

In this paper we show that state-of-the-art commercial off-the-shelf Flash memory chip technology (20 nm technology node with multi-level cells) is quite sensitive to ionizing radiation. We find that the fail-bit count in these Flash chips starts to increase monotonically with gamma or X-ray dose at 100 rad(SiO2). Significantly more fail bits are observed in X-ray irradiated devices, most likely due to dose enhancement effects due to high-Z back-end-of-line materials. These results show promise for dosimetry application.

Keywords

Cite

@article{arxiv.1809.08520,
  title  = {State-of-the-Art Flash Chips for Dosimetry Applications},
  author = {Preeti Kumari and Levi Davies and Narayana P. Bhat and En Xia Zhang and Michael W. McCurdy and Daniel M. Fleetwood and Biswajit Ray},
  journal= {arXiv preprint arXiv:1809.08520},
  year   = {2018}
}