English

Selectron Mass Reconstruction and the Resolution of the Linear Collider Detector

High Energy Physics - Experiment 2007-05-23 v1

Abstract

We have used ISAJET and the JAS LCD fast simulation to explore the precision of Snowmass Point SPS1a selectron mass reconstruction for the Silicon Detector concept. Simulating collisions at E_cm = 1 TeV, we have found that most of the information constraining the selectron mass is carried in the forward (|cos(theta)| > 0.8) region. We have also found that, for a beam energy spread of 1% (conventional RF design), detector resolution limitations compromise the selectron mass reconstruction only in the forward region. However, for a beam energy spread of less than 0.2% (superconducting RF design), the detector resolution compromises the selectron mass reconstruction over the full angular region.

Keywords

Cite

@article{arxiv.hep-ex/0507053,
  title  = {Selectron Mass Reconstruction and the Resolution of the Linear Collider Detector},
  author = {Sharon Gerbode and Heath Holguin and Troy Lau and Paul Mooser and Adam Pearlstein and Joe Rose and Bruce Schumm},
  journal= {arXiv preprint arXiv:hep-ex/0507053},
  year   = {2007}
}

Comments

6 pages, 2 figures; to appear in the proceedings of the 2005 Internaitonal Linear Collider Workshop, Stanford University, Stanford, CA, March 18-22, 2005