We have measured a response to a black body radiation and noise of the cold-electron bolometers. The experimental results have been fitted by theoretical model with two heat-balance equations. The measured noise has been decomposed into several terms with the help of theory. It is demonstrated that the photon noise exceeds any other noise components, that allows us to conclude that the bolometers see the photon noise. Moreover, a peculiar shape of the noise dependence on the absorbed power originates completely from the photonic component according to the theory. In the additional experiment on heating of the cryostat plate together with the sample holder we have observed nearly independence of the noise on the electron temperature of the absorber, which has provided another proof of the presence of the photon noise in the first experiment.

Keywords

Cite

@article{arxiv.1612.03699,
  title  = {Observation of photon noise by cold-electron bolometers},
  author = {A. V. Gordeeva and V. O. Zbrozhek and A. L. Pankratov and L. S. Revin and V. A. Shamporov and A. A. Gunbina and L. S. Kuzmin},
  journal= {arXiv preprint arXiv:1612.03699},
  year   = {2017}
}

Comments

5 pages, 8 figures