We demonstrate an experimental approach to determine magneto-optical effects which combines x-ray magnetic circular dichroism (XMCD) with x-ray interferometry, based on the concepts of Young's canonical double slit. By covering one of two slits with a magnetic thin film and employing XMCD, we show that it is possible to determine both the real and the imaginary parts of the complex refractive index by measuring the fringe shifts that occur due to a change in the sample magnetization. Our hybrid spectroscopic-interferometric methodology provides a means to probe changes in the magnetic refractive index in terms of the electron spin moment.
@article{arxiv.2504.10586,
title = {Magnetically modified double slit based x-ray interferometry},
author = {S. Atkar and Z. Tumbleson and S. A. Morley and N. Burdet and A. Islegen-Wojdyla and K. A. Goldberg and A. Scholl and S. A. Montoya and Trinanjan Datta and S. Roy},
journal= {arXiv preprint arXiv:2504.10586},
year = {2026}
}